It is the hirer’s responsibility to inspect the beams and all fittings prior to any lifting
operations being undertaken. Consult an MGF representative before lifting if there is any
doubt over the quality of the equipment or if you are unsure about any aspect of these rules.
Equipment to be used in accordance with MGF’s terms and conditions of hire.
All operations must be carried out to approved method statements and risk assessments.
PRE-LIFT CHECKS
Before lifting there are several checks which should be done:
Must ensure that the slings are not twisted or tangled
Confirm that correct lifting points are being used
Keep the loaded beams clear of obstacles – any contact could cause unsafe
release of load or beam failure
Ensure that the sling lengths and rating are suitable, and the beam does not tilt
Ensure that the centre of gravity of the caravan is positioned centrally on the
beams to ensure an even lift
Each component needs to be checked prior to each lift
Prior to first use of a new assembly, carry out a trial lift just above ground level to
ensure that straightness is maintained under its own self-weight
Ensure that the lifting beams cannot slip on the support points during the lift.
Clamps may be required
SAFE USE WARNINGS
Before operatives use the equipment, they should read and understand
these warnings:
• Do not exceed stated WLL for all of the components
• Do not rig the vertical slings more than 3 degrees from vertical.
• When moving or positioning use tag lines to control movement.
• Individual components can be heavy and care must be taken if manual handling.
• The equipment must be used in accordance with the procedures from ‘Lifting
Operations and Lifting Equipment Regulations 1998’ (LOLER).
• Operatives using this system should be suitably trained, competent and have a
clear understanding of Safe Slinging procedures.
• Never lift over or near people, ensure an exclusion zone is in place during any
lifting operations.
• Do not use on uneven ground or during high winds.
• All loads being lifted should be rigid and additional safety measures may be
required to prevent the beams from moving or twisting during the lift.
USER GUIDE SECTION 6
10