MassCore with RAVENNA and Horus / Hapi / Anubis:
Compatibility: Windows 7 Professional 64-bit and Windows 10 Professional 64-bit.
Note: Merging strongly recommends users to perform a Windows Update prior to installing Ovation v9.
Installation Steps:
• NET-MSC-GBEX1 Installation See: Installing the Merging Technologies NET-MSC-GBEX1 PCIe Ethernet Controller
Card on page 28
• Ovation Software Installation, Ovation Software Installation on page 18
• Entering Authorization Keys, See: Ovation Software Registration on page 20
• MassCore Installation, See: MassCore Installation on page 23
• Select MassCore with RAVENNA in the VS3 Control Panel (Start Menu > Control Panel > VS3 Control Panel)
Quick Setup Checklist For Systems with Horus / Hapi / Anubis
1. Shut down the system and install the MassCore NET-MSC-GBEX1 PCIe Ethernet controller card. (Card drivers are
included in the Pyramix and Ovation installers.)
2. Existing users of 64 bit MassCore must uninstall the previous MassCore version from the MT Security application.
3. MassCore users MUST configure their BIOs settings. Please see: BIOS Settings on page 15
4. Disable Windows Firewall in Windows Control Panel Security.
5. Install Google Chrome.
6. Install Ovation v9.x (This will also install Pyramix 25th Anniversary)
7. Enter your new MassCore (RTX64 - 3.0 key in MT Security Settings then import your 25th Anniversary/v9 keys in MT
Security Settings.
8. On a fresh install also in MT Security Settings install MassCore from the MassCore Tab.
9. MassCore SMP users (recommended for i7 CPU configurations and above) should launch the VS3 Control Panel and
assign 2 cores to MassCore. (A reboot will be required.)
10. In the VS3 Control Panel ensure that RAVENNA is selected in the Hardware section.
11. Configure the Switch/Router (if present) Please refer to the RAVENNA Network Guide.
12. Launch Ovation.
13. You can also launch the MTDiscovery application and double-click on the Horus / Hapi entry for browser remote
access.
14. Ensure that the Horus / Hapi / Anubis is set to the same sampling rate as Pyramix or Ovation. A warning prompt will
appear if this is not the case.
15. We recommend Horus, Hapi and Anubis users update to the latest firmware available. Obtainable here:
https://www.merging.com/products/interfaces/downloads
16. Configure I/O as required in Pyramix/Ovation and Horus / Hapi / Anubis. Please download and install the latest ANE-
MAN application in order to manage and monitor your AoIP devices from:
www.aneman.net/#download.