OPER ATING IN sTR U CTIONS
For Model 98 Beginning with Seriol No.l5,O00
Before any attempt is made to use this instrument, read the following
instructions. They were prepared to enable those having only a minimum
of experience to test app repair the magneto ignition system equally as ,--.
well as the electrical specialist. Adhere to the instructions in sequence.
Do not jump from the first test to the fourth or the third to the fiffh, etc.
1. Your Merc-O-Tronic Magneto Analyzer is shipped with a dry battery
installed in the unit. Remove the 2 metal screws at the top of the
panel. This will allow the top to swing back, and you wiII notice
that the positive (red) battery lead is disconnected. Connect this
lead to the positive (+ ) post of thebattery. (When replacing battery,
make certain positive terminal is to right side of tester and that
terminal nuts are tight.)
2. t(Zerot' meter by turning the small adjustment scre'w on front of
meter until pointer hand lines up with zero on Scal.e No. 1, left side.
This is set at the factory, but should be rechecked.
3. To determine the battery life do the following: Move switch for volt
scale No. 1 to ((ON" position. Attach small black test lead to
negative and red small test lead to positive lugs on battery. Then
place selector switch on No. 1 position. (Red pilot will be on and
vibrator will be running). Read red figures on top of Scale No. 1.
Battery should check not less than 6.5 volts or proper readings
cannot be obtained. (Each division on volt scaie equals 0.5 volt).
For bench use this analyzet can be connected to an 8 volt
storage battery power supply. For 8 volts tap off 4 cells from a 12
volt storage battery.
4. Your Merc-O-Tronic Magneto Analyzer is now ready for use.
The following batteries can be used in place of Burgess 4F5H:
Eveready 715
Neda 903 Olin 5605
RCA VS139 Ray-O-Vac 903
Mallory M903
To check low OHM resistance values see page 20.
See Page 14 for Voltage Test Procedures.
CAUTION: DO NOT CONNECT TEST LEADS TOGETHER WHEN
SELECTOR SWITCH IS TURNED TO POSITION NO. 1 AS THIS IS
A DIRECT SHORT ON THE BATTERY.
FOR ALL TEST PROCEDURES INVOLVING SELECTOR SWITCHES
1 THRU 6 - VOLT SCALE SWITCH MUST BE IN ((OFF" POSITION.
5. To check condens.er leakage (on Scale No. 5) and condenser capacity
(on Scale No. 4), plug cord into 115-volt 60-cycIe AC electrical
outlet. This is the only time 115-volt 60-cycle AC is required. To
read, press red button, the electrical charge placed in condenser is
automatically discharged when releasing red button.
6. SPECIAL NOTICE: When checking Lauson Power Products Coils
#30546, 30560 and 29632 or any coil with internal condenser the
5 m.m. pot spark wiil appear fizzy. DO NOT let this fuzzy spark
mislead you. If spark is steady, coil is good,