Merax PP195794 Manuel utilisateur

~1~
Operation Instructions
PP195794
Manual recliner&massage function

~2~
MASSAGE CHAIR
READ ALL INSTRUCTIONS
BEFORE USING THE ITEM
REMOTE CONTROL
Function of remote
MODE:D-610
Prior to use, please firstly connect controller, and then connect the power plug. Touch
the power switch lightly, the product starts working. When stopping using it, please firstly
turn off the controller and then pull out the adapter plug from the outlet.
1.The specification of power adapter: input, AC110-240V, 50-60Hz; output, DC 12V,
2500mA.
2. The product is 3D Kneading massager. Pull through it, it is in standby state. Users
can realize the function control through the hand controller.

~3~
3.“ ”“Power” key: soft on-off key. In the standby state, press the start key,
the power indicator lamp LED is normally on, press it again, it enters the standby state.
4.“” “Time” key: the default preset time of the product is10-20 minutes.
After it is used for 10-20 minutes, the product will shut down automatically for protection.
5.“” “Heat” key: if users want the product to have the spontaneous heat,
they can press heating switch key for heating.
I. Precautions for safety maintenance
1.Precautions for safety maintenance are to prevent you and other users from being
damaged or hurt and guarantee safety use. Users shall know this point.
2.Xiamen IDENO Electronics Technology Co., Ltd. (“IDENO”) shall not bear any
compensation liabilities for the loss and damage caused to the user or the third party owing to
improper use of product or accessories or any compensation liabilities for the loss and
damage to the parts owing to intentional damage and (or) crash.
3.Prior to use, please read the Instructions carefully for operating correctly. After
reading, the users shall keep it well for reference at any time.
4.Anyone during medical treatment can use the product after obtaining the instruction of
the doctor to avoid the occurrence of accident or bad effect.
5.Children are forbidden to use or sit on the massage armchair for playing, or else it
may cause accident or hurt.
6.If you use the accessories bought from the accessory market rather than that provided
by IDENO to repair, replace the normal rapid wear components and/or manual control circuit
parts, it may cause mismatching of manual control performance, and even failure of normal
operation. IDENO shall not be responsible for it.
7.IDENO does its utmost to guarantee the accuracy of product operation manual.
However, these printed files and texts may include incorrect technology or printing error,
IDENO will not be responsible for the appropriateness of the information and text, or the
error in these files and texts. We reserve the right of revising technical parameters of the
Specification and installation figures.

~4~
8.If the massage armchair doesn’t work or is observed to be abnormal, please stop using
it immediately and contact the retailer.
9.If the users feel abnormal in use, please stop using it immediately;
10.Please use it in a dry and ventilated place without direct sunshine. For the human body
fitness, the massage each time should be as better as for at most 30 minutes.
11.The moron and disable who cannot express their wills cannot use the massage
armchair by themselves.
12.Please don’t use the product when the power or power plug is damaged. Or else, it
may cause electric shock or short circuit or even fire accident. In this case, please contact the
retailer, agent or manufacturer for repairing and replacement;
13.Prior to use, please match the hand controller with power DC plug and then put
through the power. After that, touch the power switch to start massaging. When stopping
the machine, please firstly turn off the main power, and then pull out the power DC plug
and at last pull out the hand controller plug.
14.Please don’t use diluents such as ethyl alcohol and gasoline to clean the massage
armchair.
II.I. Warnings
1.If the product is idle for a long time, please cut off the power.
2.If the power line is damaged, please don’t dismantle it by yourself. It must be replaced
or repaired by our company or the retailer designated by our company.
3.When the leather sheath or cloth sheath is damaged, please replace it immediately and
don’t use it any more to avoid other damage.
4.Please don’t immerse the controller in the water or impose heavy load on the controller
to avoid the failure of hand controller.
5.People who suffer from varies diseases, feel ill or pregnant cannot use the product.
The above agreement is applicable to all the IDENO products and IDENO enjoys the final
power of interpretation.

~ 5~
HEALTH CAUTION
MAINTAINANCE INSTRUCTIONS
If you have any concerns regarding to your health, consult your doctor
before using this product.
Individuals with pacemakers should not use this product.
If you have pain in a muscle or joint after using for a prolonged period
of time, discontinue using and consult your doctor. Persist pain could be
a symptom of a more serious condition.
TO STORE:
Place unit in its box or safety dry and cool place. Avoid putting
chair in contact with sharp edges or pointed objects which might
cut or puncture the fabric. Do not wrap attached power cord around
the unit. DO NOT pull the unit by power cord.
TO CLEAN:
Ensure the unit is unplugged from the power source, and allow the
unit to cool down before cleaning.
Do not use any liquid to clean. Clean fabric cover by wiping with
a damp sponge, using a mild detergent or suds. Pat with clean, dry
cloth.
Do not use any abrasive cleaners, brushes, gasoline, kerosene,
glass furniture polish, paint thinner or water hotter than 120︒F to
clean the unit.
I. Wa ngs

~ 6~
OPERATING INSTRUCTION
TECHNICAL SPECIFICATIONS
Model:PP195794
Rated Voltage :100V-240V~
Rated Frequency :50Hz/60Hz
Open it
Press to open it

~ 7 ~
Assembly Instructions
Please read the following instructions prior to assembling this product:
1. To avoid damage, assemble this product on a non-abrasive surface such
as carpet.
2. Make sure all bolts are tightly fastened before use.
3. For home use or light commercial use only.
4. Please make sure you have all parts before assembly.
General Assembly information Guide

~ 8 ~
Parts List
1 PCS 1 PCS
1 PCS 1 PCS
1 PCS 1 PCS
A B
C D
E F

~ 9 ~
Step 1
1 Place the Seat (A) on a flat smooth surface.
Take out the bag which holds a rectangle box.
2 Take out the transformer F 1pc.
F
A

~ 10 ~
Step 2
Attach backrest (B) to main frame (A) by aligning the metal grooves on
backrest to brackets on the main frame as shown.
Ensure the backrest (B) slides down fully over the brackets on the main frame
(A).
B
A
Table des matières
Autres manuels Merax masseur


















