Truck Load Out (TLO)
The TLO software can be configured to work with the scale keypad, external
touch screen, external push buttons or a combination of the above. The TLO uses
its own accumulator so there is no conflict with any of the 4 main totalizers.
Programming Setup at the Belt Scale Integrator
Settings for the TLO system can be found at Setup>Truck Load Out Setup
menu.
SETUP>Truck Load Out Setup Menu
Truck Load Out On/Off – Enables the Truck Load Out system.
Require Truck ID On/Off – Requires a Truck ID to be entered before
the load can begin.
Clear ID on Complete On/Off – Clears Truck ID at completion of load.
Require Input On/Off – Requires a digital input to be activated
before the load can begin. The input and configured
in the I/O menu.
Auto Print Ticket On/Off – Automatically print a truck ticket on
completion of load. Requires optional ticket printer.
Auto Clear Target On/Off – Clear Target weight at completion of load.
Stop Timer On Controls Truck fill timer.
Output Truck fill timer is stopped when the
Truck Output turns off.
Clear Truck fill timer is stopped when the
load is complete and the operator
Clears the weight.
Min. Rate Truck fill timer accumulates time only
when the Rate is above the Minimum
Rate setting found in the
SETUP>Calibration Setup menu.
Cutoff The amount to subtract from the Target weight to turn
off the Cutoff output.
Min. Target Minimum allowable Target weight
Max. Target Maximum allowable Target weight
TLO Inputs
Any of the 4 digital Inputs can be configured for the following functions. Inputs
can be configured under I/O>Inputs menu.
I/O>Inputs
Truck Load Out Clear Clears Truck accumulator when the load is complete.
Truck Load Out Stop Stops the truck load out process and turn off outpu
(This should NOT be used as an E-Stop.)
Truck Load Out Start Starts the Truck load out process
Truck Load Out Enable
If setting Require Input = ON then this input needs to
be ON for truck load out to start.