1. General Instructions .................................................................... 1
1.1 Function features ............................................................... 1
1.2 Front panel illumination...................................................... 1
1.3 Specification....................................................................... 2
2. Installation and Wiring................................................................. 3
2.1 Installation .......................................................................... 3
2.2 Open Remote Display........................................................ 4
2.3 Inside Structure Diagram ................................................... 5
2.4 Power/Communication Terminals Connection .................. 6
2.4.1 Power Cable Connection ......................................... 6
2.4.2 Communication Terminals Connection.................... 6
3. Application Illumination ............................................................... 8
3.1 Mirror Display Function ...................................................... 8
3.2 Communication Address Setting........................................ 8
3.3 Communication Mode Setting............................................ 9
3.4 Wireless Communication Function .................................. 10
3.5 Red&Green lights output control function........................ 11
4. Working Mode ........................................................................... 12
4.1 Normal Display Mode....................................................... 12
4.2 Mirror Display Mode ......................................................... 13
5 .Communication Protocols ......................................................... 14
6. Hanging Board Dimension Diagram ......................................... 32

1
1. General Instructions
GM8895 Remote Display is one of our independent innovation
instrument for end show, which is used with various electronic
weighing instruments at wide application:AD-4321
、
、、
、
AD-4323
、
、、
、
TOLEDO & Fairbanks R2500
、
、、
、
Rinstrum, UMC600
、
、、
、
GSE50 series
、
GSE60 series
、
WI-125
、
、、
、
WI-127
、
、、
、
DF1500 and so on.
1.1 Function features
Detachable sunlight shelter to ensure clear vision in sunlight
Dustproof and Waterproof housing – IP65, Easy installation
RS232/RS485/current loop communication terminals
Wireless Communication Function
Mirror Display mode
1.2 Front panel illumination
P 1-1
①
Waterproof Signal Communication Input: connect
communication lines with remote display (NOT used for wireless
mode).

2
②
Waterproof Power Cable Input: Connect power cable with
remote display.
③
Lock Buckle: Lock front and back board of remote display.
④
Wireless Communication Sign Receiver: Receive weighing
data from the indicator in wireless communication (optional
function).
Main display: Display weighing data, including decimal point and
minus sign.
Weight unit
lb
:
Weight unit is pound.
t
:
Weight unit is ton.
Kg
:
Weight unit is kilogram.
Status light
GROSS: Light for gross weight.
NET: Light for net weight.
MOTION: Light for motion.
1.3 Specification
Specification
T em pe rat u r e -10~40
℃
M ax H um id i t y 95%R.H
Power Supp ly AC90V~260V 50~60Hz
Communication
interface
RS232/485; 0~20mA
current loop;
Wireless
(
915MHz
)
D im e ns i o n
900×280×106
(
mm
)
(wi t hout sunlight
shelter )
D im e ns i o n 903×296×257
(
mm
)
(wi t h sunlight
shelter )

3
2. Installation and Wiring
2.1 Installation
User can fix Remote Display on wall or strong metal stand
according to actual application. The following instruction is to fix on
wall for example.
1. Fix hanging board on
wall (Suggesting using M6
dilatants bolts to fix hanging
board). Please refer P29
Hanging Board Dimension
Diagram.
P 2-1
2. Put Remote
Display on the hanging
board fixed on wall.
P 2-2
3. Ensure Remote Display to be
hanged firmly, and then screw tightly
to fix Remote Display on hanging
board.

4
2.2 Open Remote Display
Please open Remote Display as following instruction before
connecting power cable /communication terminals or related
operation, and then begin to run.
1. Loose four lock buckles (location as following diagram).
P 2-4
2. Open the front panel of Remote Display, install built-in
bracket in Remote Display to support front panel.
P 2-5
3. The left area is for these electric circuit boards, now begin to
connect power cable / communication terminals or operate
correlatively.
P 2-6

5
2.3 Inside Structure Diagram
GM8895 Remote Display inside structure and its connection
diagram are following:
P 2-7

6
2.4 Power/Communication Terminals Connection
2.4.1 Power Cable Connection
P 2-8
N
:
Null wire G
:
Ground wire L
:
Live wire
2.4.2 Communication Terminals Connection
The connection between the indicator and GM8895 remote
display are different according to different communication mode.
Please refer Chapter 3.3 (P9) for communication mode.
(
1
)
RS232 communication mode
The connection diagram between weighing the indicator and
GM8895 remote display are following:
P 2-9

7
(
2
)
RS485 communication mode
The connection diagram between weighing the indicator and
GM8895 remote display are following:
P 2-10
(
3
)
0
~
20mA Electric current loop
The connection diagram between weighing the indicator and
GM8895 remote display are following:
P 2-11

8
3. Application Illumination
3.1 Mirror Display Function
With this function, weighing data can be displayed in reversed
format to suit special requirement.
Push SW2 switch
(
blue switch
)
D1 to
ON, Then power on again, weighing data
will be displayed in reversed format.
3.2 Communication Address Setting
Through D3
、
D4
、
D5
、
D6 of SW2 switch (blue switch) to set
communication address, after setting, power on again. Near
number side is defined 0, and near “ON” side is defined 1. Please
restart GM8895 to make new setting effect. The address table:
D3 D4 D5 D6 Display
Address
0 0 0 0 0
0 0 0 1 1
0 0 1 0 2
… … … … …
1 1 1 1 15
For example: If present SW2 switches
are same as right Diagram, the current
remote Display address is “3”.
When Remote Display address is “0”, it works in single
communication mode, and address is meaningless for
communication; while the address is not “0”, it works in multiple
communication mode, and address should be matched when
communication.