Marport Seine Manuel utilisateur

Seine Sensors
Service Manual


Contents | ii
Contents
Legal.................................................................................................4
History...........................................................................................................................................................................4
Copyright......................................................................................................................................................................6
Disclaimer....................................................................................................................................................................6
Introduction and Presentation..........................................................7
Introduction................................................................................................................................................................ 7
Applications.................................................................................................................................................................8
Safety Guidelines.................................................................................................................................................... 10
Description................................................................................................................................................................. 11
Firmware.........................................................................................................................................................11
Technical Specifications........................................................................................................................... 11
Main Parts.....................................................................................................................................................14
Installation Steps....................................................................................................................................................15
Sensor Configuration...................................................................... 16
Installing Mosa2..................................................................................................................................................... 16
Connecting the Sensor to Mosa2......................................................................................................................17
Seine Explorer Specific Settings.......................................................................................................................19
Sounding Modes..........................................................................................................................................19
Configuring the Uplink, Up (Side) and Down Settings...............................................................20
Uplink................................................................................................................................................. 20
Up/Down Soundings......................................................................................................................21
Target Strength...............................................................................................................................23
About Time Variable Gain...................................................................................................................... 24
Configuring the Noise Floor..................................................................................................................25
Calibrating the Sensor for Target Strength Value........................................................................ 26
Setting Up the Installation........................................................................................................26
Calibrating the Sensor in Mosa2............................................................................................. 27
Canceling the Ringing..............................................................................................................................30
Configuring Seine Sensor Telegrams..............................................................................................................33
Depth...............................................................................................................................................................33
Height............................................................................................................................................................. 34
Temperature.................................................................................................................................................34
Down Sounding...........................................................................................................................................35
Configuring the Uplink Power..........................................................................................................................36
Testing Measures....................................................................................................................................................37
Updating the Sensor............................................................................................................................................. 38
Downloading the Firmware................................................................................................................... 38
Updating the Sensor.................................................................................................................................39
Exporting Sensor Configuration Settings for Record Keeping.............................................................40
Exporting Sensor Configuration Settings for the Receiver.................................................................... 41

Contents | iii
System Configuration and Display..................................................43
Adding the Sensor to the Receiver..................................................................................................................43
Defining the Trawl Gear Type..............................................................................................................43
Adding the Sensor with a Configuration File.................................................................................44
Adding the Sensor Manually.................................................................................................................46
Adding the Sensor to the Receiver.........................................................................................46
Configuring the Sensor Settings..............................................................................................47
Configuring Data Display on Scala/Scala2...................................................................................................50
Installation..................................................................................... 57
Installing the Seine Sensor on a Purse Seine............................................................................................. 57
Maintenance and Troubleshooting................................................. 60
Interference Check................................................................................................................................................ 60
Spectrum Analyzer Display................................................................................................... 60
Checking Noise Interference..................................................................................................61
Checking Noise Interference.................................................................................................62
Charging the Sensor............................................................................................................................................. 65
Cleaning the Sensor..............................................................................................................................................66
Maintenance Checklist.........................................................................................................................................67
Troubleshooting......................................................................................................................................................68
Firmware downloaded on DealerWeb cannot be read by Mosa2............................................ 68
Mosa2 does not open due to error message...................................................................................68
Adding a Sensor to M2 Receiver......................................................................................................... 68
Sensor cannot connect in wireless connection..............................................................................69
Sensor does not connect correctly with Mosa2 when using the Configuration
Cable..........................................................................................................................................................69
Echogram is fixed and blue...................................................................................................................70
Data in Scala/Scala2 is wrong...............................................................................................................71
Support Contact...................................................................................................................................................... 72
Appendix......................................................................................... 73
Frequency Plan........................................................................................................................................................73
Index.................................................................................................................78

Seine Sensors | V7 | Legal
Legal
History
V1 03/09/18 First release
V2 07/06/18
• New troubleshooting topic: Sensor cannot connect in
wireless connection on page 69
•Interference Check on page 60: more detailed
information about Spectrum page.
V3 11/30/18
•Frequency Plan on page 73: drawings have been
changed, frequencies are now allocated between 34 kHz
and 36 kHz and frequency ranges of narrowband and
wideband hydrophones are indicated.
V4 07/16/20 Now documents Mosa2 version 02.03, Scala version
01.06.34 and Scala2 version 02.02.
V5 10/01/20
Technical Specifications on page 11: the typical battery
life is now specified separately for SE50 (depth) and SE100
(height).
V6 03/08/21
• Now documents Mosa2 version 02.07.
•Connecting the Sensor to Mosa2 on page 17: added
guidance on how to connect sensor to Mosa2 using the
Configuration Cable product.
• Added troubleshooting topic: Sensor does not connect
correctly with Mosa2 when using the Configuration
Cable on page 69
•Added details on the Down 1 + Down 2 sounding mode
in Configuring the Uplink, Up (Side) and Down Settings
on page 20.
• Added contact details for the sales offices in South
Africa and Norway in Support Contact on page 72.
| 4

Seine Sensors | V7 | Legal
V7 07/05/21
• Now documents Scala2 version 02.04 and Mosa2
version 02.07.
• In Technical Specifications on page 11, corrected
the battery lifetime of the Seine Explorer.
• Replaced term Configuration Plug by Configuration
Cable.
•Connecting the Sensor to Mosa2 on page 17:
Updated distance between other electrical devices and
the computer: 1 m instead of 50 cm.
•Service manuals: removed Replacing Parts chapter.
Maintenance procedures are now documented in
Maintenance Manuals, that are specific to each model
of bottle used to protect the internal components.
| 5

Seine Sensors | V7 | Legal
Copyright
© 2021 Marport. All Rights reserved.
No part of this document may be reproduced, stored in a retrieval system or transmitted in any
form by any means; electronic, mechanical, photocopying or otherwise, without the express
written permission from Marport. “Marport”, the Marport logo and Software Defined Sonar are
registered trademarks of Marport. All other brands, products and company names mentioned
are the trademark and property of its respective owners only. Marport is a division of Airmar
Technology Corporation.
Disclaimer
Marport endeavors to ensure that all information in this document is correct and fairly stated, but
does not accept liability for any errors or omissions.
The present user guide is applicable for the following versions:
• Scala: 01.06.06-01.06.34 / Scala2: 02.04
• Mosa2: 02.07
Patents apply to products. U.S. Patents 9,772,416; 9,772,417
| 6

Seine Sensors | V7 | Introduction and Presentation
Introduction and Presentation
Read this section to get a basic knowledge of your Seine sensor.
Tip: Click Marport logo at the bottom of pages to come back to the table of contents.
Introduction
The Seine sensor is mounted on the lead line of a purse seine in a robust protective steel framed
housing. It relays data back to the wheelhouse from the moment the purse seine is shot away and
during the fishing operation. It has an omnidirectional uplink signal, which ensures that there is no
loss of signal during the fishing operation.
There are different Seine sensors:
• Seine sensor with depth.
• Seine sensor with depth and temperature
• Seine sensor with depth, height and temperature.
• Seine Explorer with temperature, depth, height, battery and echogram.
During the shot, depending on your type of Seine sensor, you can see the depth of water above the
lead line, the distance from the lead line to the seabed (height) and an echogram of the area below
the lead line. On most recent models, there is also an echogram of the contents of the purse seine
during its descent. Measuring the depth at rapid time intervals provides the user with an accurate
descent rate of the lead line.
When purse seining in shallow water, Marport's Seine sensors are an essential tool to ensure the
gear is kept at a safe distance from the seabed. This way, you can avoid damage to the gear.
Seine sensors with depth only or with depth, height and temperature can send depth and
temperature data to a Scanmar system. There is also a version of Seine sensors with depth and
temperature that is compatible with Simrad PI systems.
Note:
These labels tag topics or actions that are specific to Scala and/or Scala2.
Depending on the version you have, you may follow either one of these labels.
| 7

Seine Sensors | V7 | Introduction and Presentation
Applications
Here are some examples of data received from Seine sensors displayed in Scala/Scala2.
Seine Explorer and Seine sensors with depth and height
1. Temperature
2. Battery level
3. Leadline
4. Distance from the sensor to the
seabed
5. Seabed
6. Seabed (echosounder)
7. Depth of seine sensors
| 8
Table des matières
Autres manuels Marport Accessoires