MAHA Air 1 Manuel utilisateur

D1 1301BA1-GB03
Air Stream Fan
AIR
for Dynamometers
Original Operating Instructions

AIR
II D1 1301BA1-GB03
EDITION
Version 3 dated 14.08.2003
D1 1301BA1-GB03
©MAHA GMBH&CO.KG.
All rights reserved. Any reproductions of this document, partial or complete, are only allowed with
prior consent of MAHA GmbH & Co. KG.
All rights reserved in cases of patent granting or registration of design.
The contents of this version have been checked with great care. However, errors cannot be fully
excluded. Please contact MAHA should you find errors of any kind.
Subject to technical change without notice.
These instructions are intended for users with previous technical knowledge in the field of vehicle
testing technology as well as basic computer knowledge and MS-Windows operating system
application.
Windows and Windows for Workgroups is a registered trademark of the Microsoft-Corporation.
MANUFACTURER
MAHA Maschinenbau Haldenwang GmbH & Co. KG.
Hoyen 20
D-87490 Haldenwang/Allgäu
Telephone: 08374 / 585-0
Telefax: 08374/ 585-499
Internet: http://www.maha.de
SERVICE
MAHA Maschinenbau Haldenwang GmbH & Co. KG.
- Service dept. -
Hoyen 20
D-87490 Haldenwang/Allgäu
Hotline: 08374 / 585 + extension
260 for brake testers, test lanes
280 for lifting technology
290 for performance testers, exhaust and air condidioning service equipment
Service: 08374 / 585-110 bis - 113, - 115
Telefax: 08374 / 585-491

AIR
D1 1301BA1-GB03 III
TABLE OF CONTENTS
1General Information ..................................................................................................1
1.1Preliminary Information..................................................................................................................1
1.2Safety Instructions..........................................................................................................................1
1.3Technical Specification ..................................................................................................................2
1.4Noise Emission ..............................................................................................................................3
2Installation and Operations......................................................................................5
2.1Installation......................................................................................................................................5
2.1.1Air Stream Fan AIR 1 and AIR 2 ....................................................................................5
2.1.2Air Stream Fan AIR 5 and AIR 7 ....................................................................................6
2.2Preparations before Starting the Fan.............................................................................................8
2.3Switching On the Air Stream Fan...................................................................................................8
2.3.1Cooling Fan with ON/OFF Switch...................................................................................8
2.3.2Cooling Fan with Cable Remote Control........................................................................9
2.3.3Air Stream Fan with Infrared Remote Control ..............................................................10
2.3.4Air Stream Fan with 2 Increment-Air Flow Adjustment.................................................11
2.3.5Air Stream Fan with Infinitely Variable Air Flow Adjustment ........................................11
2.4Additional Fan..............................................................................................................................12
3Troubleshooting......................................................................................................13


AIR
D1 1301BA1-GB03 1
1 General Information
1.1 Preliminary Information
The air stream fan simulates the air stream that is normally produced during driving simulation of
motor vehicles during performance tests on roller dynamometers.
The air cooling fan blows cool air via a low-lying, large exhaust passage on the engine cooler and
under the vehicle. The engine temperature of the tested vehicles is thus maintained at normal
operational temperature. The heat accumulation underneath the vehicle is blown off, avoiding
damage to the corrosion protection of the automobile body and overheating of the the drive unit
and tires.
1.2 Safety Instructions
Read the standard operating procedures and user’s manual carefully before operating
the cooling air fan! MAHA will not accept any claims for damage or service costs occurred
due to non-compliance with these operating instructions.
The accident prevention rules and regulations of the Professional Association, the Workplace
Directive and the Reich Garage Directive, as well as the latest relevant VDE (Association of
German Engineers) regulations shall apply to the operation of the air cooling fan.
The official accident prevention regulations must be complied with at all times.
All work done on electrical parts of the equipment is to be carried out by trained, qualified
electricians or service technicians only. Before any kind of service or repair work is done,
disconnect the cooling air fan from all power supply and turn off the main switch, if
necessary!
The air cooling fan should be operated by trained personnel only!
Protect all parts of the installation from humidity and moisture!
The air cooling fan is only to be used for its intended purpose as described in the operating
instructions (Simulating the airstream which occurs during normal driving conditions while
conducting performance tests on roller dynamometers)!
Make sure that the cooling fan is properly and firmly positioned before starting operation!
Do not deposit any parts (tools, vehicle parts etc.) on the cooling fan!
Never insert any objects into the guard grilles of the cooling fan!
The noise emission value created when the air cooling fan is in operation is more than 70 dB
(A) in the work area of the operational personnel. Ear protection should be worn. The
protection should be approved for noise levels of up to 120 dB(A).

AIR General Information
2 D1 1301BA1-GB03
1.3 Technical Specification
Model Air 1 Air 2 Air 5 Air 7
Air output [m3/h] 6200 16500 21000 26500
Air stream [km/h] 70 70 78 98
Motor power [KW] 0,4 1,1 2,2 5,5
Fuse [A] 10 10 16 25
Power connection [V] 230 400 400 400
Version axial axial radial radial
Control Condensor Contactor Contactor Star/Delta
Dimensions
Depth [mm]
Width [mm]
Height [mm]
440
830
960
710
1120
1054
700
1665
960
700
1665
960
Weight [kg] 100 100 280 280
Swinging diameter [mm]
700
890
-
-
Depth [mm] with air flow
scoop - - 995 995
Model Air 7/1 Air 7/2 Air 5/5 Air 7/5
Air output [m3/h] 26500
21000/
26500 0 - 21000 0 - 26500
Air stream [km/h] 98 78/98 0 - 78 0 - 98
Motor power [KW] 7,5 2,5/6 2,2 5,5
Fuse [A] 35 35 25 35
Power connection [V] 400 400 400 400
Version radial radial radial radial
Control Star/Delta Dalander Regulation Regulation
Dimensions
Depth [mm]
Width [mm]
Height [mm]
700
1665
960
700
1665
960
700
1665
960
700
1665
960
Weight [kg] 280 280 280 280
Swinging diameter [mm]
-
-
-
-
Depth [mm] with air flow
scoop 995 995 995 995

General Information AIR
D1 1301BA1-GB03 3
1.4 Noise Emission
The noise emission value created when the air stream fan is in operation is more than 70 dB (A)
in the work area of the operational personnel.
Ear protection should be worn !
The ear protection should be approved for noise levels of up to 120 dB(A).

AIR General Information
4 D1 1301BA1-GB03

AIR
D1 1301BA1-GB03 5
2 Installation and Operations
2.1 Installation
2.1.1 Air Stream Fan AIR 1 and AIR 2
Air stream fan AIR 1
A: Air exhaust
B: Handle to swing around the fan
C: Lever to lock the fan
D: Power-supply plug
The air stream fan AIR 1 is equipped with a power-supply plug (D)for 230 V mains supply. The
ON/OFF switch is situated on the back side of the fan.
The air stream fan AIR 2 must be connected to 400 V three-phase mains. The air stream fan is
equipped with 4 rollers and can therefore easily be moved to the intended point of use. To ensure
a stable position during operation, two of the rollers are equipped with a locking brake. Normally,
a cable remote control is used to switch on and off the cooling fan. If, however, a MAHA
dynamometer is used, the air stream fan can be operated with the dynamometer's remote control.

AIR Installation and Operations
6 D1 1301BA1-GB03
2.1.2 Air Stream Fan AIR 5 and AIR 7
Air stream fan AIR 5 and 7
A: Electro box
B: ON/OFF switch, rotary switch
(depending on model and equipment)
C: Connection to LPS
D: Power-supply plug for 400V three-
phase mains
E: Cable holder
F: Air entry
G: Lashings for the air flow scoop
H: Three-phase motor
I: Locking brake for guidance rollers
J: Air exhaust
The air stream fan AIR 5 is available in two different versions. The AIR 5 blows with a constant air
speed and is turned on and off via the dynamometer's remote control. The AIR 5/5 offers a
infinitely variable air flow adjustment which can be regulated manually via a rotary switch situated
on the cooling fan or automatically via the roller RPM of the dynamometer.
Ce manuel convient aux modèles suivants
7
Table des matières