Page 6 of 7
Revised October 16,2023
VADER User Guide (MAN405)
Voltmeter Characteristics:
•High Voltage Isolation for Operator Safety : Tested to 1kV steady-state/15kV transient voltage levels
(designed for higher voltage level isolation) – operator isolated from power supply
•Non-Saturating : Voltmeter will not saturate on 5.7VDC and higher ranges with superimposed AC
signals up to 120VAC (for readings up to approximately 50% of full scale at 60Hz) and/or inductive spikes
up to 2kV appearing at the input terminals
•Extensive Ranges : Various DC Ranges (40mV full scale to 570V full scale) plus 4V, 40V, and 400V AC
Ranges. All DC Ranges have <80ms response times for accurate On/Off pair readings during fast current
interruption cycling (for example, 700ms ON / 300ms OFF).
Power Source:
•21700 Lithium Ion rechargeable battery
•Interior battery charging port
•Re-chargeable battery lasts approximately 8 hours with continuous usage
•Battery easily replaced in the field
Communication with Tablets/Phones via WPAN technology:
•Android™ compatible
•Connection status indicator, LED, on case exterior
Connectors:
• 5-pin connector for optional push-button data-probe triggering of readings
•Two shrouded banana jacks (one red/one black) – 1,000V; CAT III (IEC 61010 rating)
Integrated Sub-meter GPS System:
•Internal GPS antenna
Environmental:
•IP65 Rated
Temperature Ranges:
•Operating Range: 32°F to 104°F (0°C to 40°C) • Battery Charging Range: 32°F to 104°F (0°C to 40°C)
• 5-7/8" long x 3.5” wide x 1.75” high
Case Dimensions (approximate):
Weight: •0.85lb