OPERATION MANUAL

Caution Symbol
Caution :
* Risk of electric shock !
Caution :
* Do not apply the overload
voltage, current to the input
terminal !
* Remove test leads before open
the battery cover !
* Cleaning - Only use the dry
cloth to clean the plastic case !
Environment Conditions
*
Installation Categories III 600V.
*
Pollution Degree 2.
*
Altitude up to 2000 meters.
*
Indoor use.
*
Relative humidity 80% max.
Equipment protected throughout
by double insulation or reinforced
insulation.

TABLE OF CONTENTS
1. FEATURES................................................................ 1
2. SPECIFICATIONS......................................................
.
2
3. FRONT PANEL DESCRIPTION.....................................6
3-1 Display................................................................6
3-2 Power ON button................................................. 6
3-3 Hold button......................................................... 6
3-4 Select button....................................................... 6
3-5 Hz button............................................................ 6
3-6 Range button .....................................................
.
6
3-7 Function switch...................................................
.
6
3-8 V/Ωterminal ......................................................6
3-9 COM terminal .....................................................
.
6
3-10 mA terminal.......................................................6
3-11 10 A terminal.....................................................6
3-12 Handle of power generator................................. 6
3-13 Stand................................................................ 6
3-14 Battery compartment/cover................................ 6
3-15 Power type switch ( G/B switch )........................
.
6
4. POWER TYPE SELECTION........................................ 6
MEASURING PROCEDURE..........................................
.
8
5-1 Precautions & preparations for measurement.......
.
8
5-2 Power management............................................. 8
5-3 Symbols & Units of Display ..................................9
5-4 Voltage ( ACV/DCV ) measurement....................... 10
5-5 Resistance measurement.....................................
.
10
5-6 Continuity, Diode measurement............................ 10
5-7 Capacitance measurement...................................
.
12
5-8 Current mA ( AC/DC ) measurement..................... 13
5-9 Current 10A ( AC/DC ) measurement....................
.
13
5-10 Smart/Auto function selection............................. 14
5-11 Range selection.................................................
.
14
5-12 Hz measurement...............................................
.
15
5-13 Data Hold.......................................................... 15
6. MAINTENANCE.......................................................... 15
7. OPTIONAL ACCESSORIES & ADAPTERS .....................
.
17
8. PATENT.................................................................... 17
9. THE ADDRESS OF AFTER SERVICE CENTER................18

1. FEATURES
* Green power, battery is no need, power supply from the
handy generator, operate the generator 10 to 20 seconds
will offer 10 minutes energy typically.
* Hybrid power, meter also can supply by the battery.
* Meet CAT III-600 V.
* 6000 counts A/D, high resolution.
* ACV, ACA, DCV, DCA, ohms, continuity, Hz,
Capacitance, Diode, Data hold.
* Smart function, Auto range or manual range with hold.
* Smart operation, Build in 4 intelligent function :
" V ", " Ω", " mA ". " 10A ".
* " V " function can select ACV, DCV automatically with
auto range.
*"Ω" function can select the Resistance , Diode,
Continuity beeper, Capacitance automatically with
auto range.
* " 10A " " mA " function can measure ACA, DCA with
auto range.
* Data hold ( auto range ).
* Auto shut off is available to save battery life.
* Both 10 A, mA current range are build fuses for safety
consideration.
* 10 M ohm impedance for voltage circuit.
* Built-in overload protection for most ranges.
* LSI circuit provides high reliability and durability.
*Patent.
* Uses durable, long-lasting components, enclosed in
strong, light weight ABS-plastic housing.
* Full line optional adapters : Clamp adapter,
Tachometer adapter, Pressure adapter, Humidity
Adapter, Sound level adapter, Anemometer adapter,
Light adapter, EMF adapter.
1

2. SPECIFICATIONS
2-1 General Specifications
Green power * Green power, battery is no need,
and power supply from the handy
Hybrid power generator, operate 10 to 20
seconds the generator will offer
10 minutes energy typically.
* Hybrid power, meter also can
supply by the battery power.
Display 46 mm x 45 mm large LCD display.
Measurement ACV, ACA, DCV, DCA, ohms,
continuity beeper, Hz, Capacitance,
Diode, Data hold.
A/D counts no. 6000 counts.
Range selection Smart function, auto range or
manual range selecting.
Smart function " V " function can select ACV, DCV
automatically with auto range.
" Ω" function can select the
Resistance, Diode, Continuity
beeper, Capacitance automatically
with auto range.
" 10A " " mA " function can measure
ACA, DCA with auto range.
Data hold To freeze the display reading on the
LCD display.
* Available for auto range only.
Power On/Off If meter is not operated within 3
management minutes will auto power switch off.
Polarity Automatic Switching, " - " indicates
negative polarity.
Sampling time Approx. 0.5 to 1 second.
Operating 0 to 50 (32 to 122 ).℃℉
Temperature
2

Operating Less than 80% RH.
humidity
Power Green power :
Supply Power from the handy generator,
battery is no need.
Battery power :
DC 3V battery ( CR-2032 ) x 2 PCs.
Power consumption DC 3 mA.
Weight 340 g/0.75 LB.
Dimension 152 x 78 x 45 mm
( 6.0 x 3.1 x 1.8 inch )
Accessories Red and Black Test Leads........ 1 Set
Included Instruction Manual..................
.
1 PC
Optional Full line adapters :
accessories * ACA/DCA current adapter :
CA-502, CA-203, CA-501
* ACA current adapter : CA-201
* Pressure adapter : PS-403
* Light adapter : LX-02
* EMF adapter : EMF-824
* Sound level adapter : SL-406
* High voltage probe : HV-40
2-2 Electrical specifications (23±5 )℃
DC/AC Voltage
* auto range
Range 6 V /60 V/600 V
Resolution 0.001 V /0.01 V/0.1 V
Accuracy DCV : ± ( 1 % + 2d )
ACV : ± ( 1.2 % + 5d )
Input impedance 10 M ohm.
Over load protection AC/DC 600 V.
Remark
* The input impedance is 10 Mega ohm.
* ACV specification be tested on sine
wave 50/60 Hz.
* For smart function ,the ACV start
measurement voltage is larger than
400 mV ± 100 mV.
3

DC/AC Current
* auto range
Range mA range 600 mA/60 mA
10 A range 10A
Resolution mA range 0.1 mA/0.01 mA
10 A range 0.01 A
Accuracy mA range ± ( 1.2% + 2d )
10 A range ± ( 1.5% + 2d )
Over load mA range 630 mA fuse
protection 10 A range 10 A fuse
Remark
* ACA specification be tested on
sine wave 50/60 Hz.
* For smart function ,the ACA start
measurement is
10 A range : 1.50 A.
mA range : 1.50 mA.
OHMS
* auto range
Range 600/6 K/60 K/600 K/6 M ohm
Resolution 0.1/1/10/100/1 K ohm
Accuracy ± ( 1% + 3d )
Over load protection ± 350 DCV, 350 ACV
Capacitance
* auto range
Range 6 nF/60 nF/600 nF/6 uF/60 uF
Resolution 0.001 nF/0.01 nF/0.1 nF/0.001 uF/
0.01 uF
Accuracy ± ( 3% + 5d )
Remark
Discharge capacitor before testing.
Frequency
Range 40 Hz to 1 KHz.
Resolution 1 Hz.
Accuracy ± ( 0.3% + 2d )
Input impedance 10 M ohm.
Over load protection AC/DC 600 V.
4

Diode
Short/non conductance, good/defect test.
Continuity
If measuring resistance is less than 10 ohm, the beeper
will sound .
5

3. FRONT PANEL DESCRIPTION
Fig. 1
3-1 Display
3-2 Power On button.
3-3 Hold button
3-4 Select button
3-5 Hz button
3-6 Range button
3-7 Function switch
3-8 V/Ωterminal
3-9 COM terminal
3-10 mA terminal
3-11 10 A terminal
3-12 Handle of power generator
3-13 Stand
3-14 Battery compartment/cover
3-15 Power type switch ( G/B switch )
6

4. POWER TYPE SELECTION
4-1 Power supply from the generato
r
( Green power supply )
1)Select the " Power type switch " ( 3-15, Fig. 1 ) to
the " G position " ( Green power position ).
There is a " Power generator's handle " ( 3-12, Fig. 1 )
on the top of the housing case.
LCD display
Power generator's handle
2)Lift and extend the " Power generator's handle "
and rotate the handle in clockwise direction will
generate the power energy into the meter, refer
to Fig. a, b, c.
Fig. a
Fig. c
Fig. b
c. Wind-up the generator 10 to 20 seconds will offer 10
minutes energy typically. If wind-up the generator
more time, the meter will be saved more energy and
let the meter be operated for a long period.
7
Table des matières
Autres manuels Lutron Electronics Multimètre

Lutron Electronics
Lutron Electronics LCR-9184 Manuel utilisateur

Lutron Electronics
Lutron Electronics DM-9962SD Manuel utilisateur

Lutron Electronics
Lutron Electronics DM-9030 Manuel utilisateur

Lutron Electronics
Lutron Electronics DM-9961 Manuel utilisateur

Lutron Electronics
Lutron Electronics AM-4205A Manuel utilisateur
Manuels Multimètre populaires d'autres marques

Gossen MetraWatt
Gossen MetraWatt METRAmax 6 Manuel utilisateur

PeakTech
PeakTech 4000 Manuel d'utilisation et d'entretien

YOKOGAWA
YOKOGAWA 90050B Manuel utilisateur

Gossen MetraWatt
Gossen MetraWatt METRALINE DMM16 Manuel utilisateur

Fluke
Fluke 8846A Manuel d'utilisation et d'entretien

Tempo Communications
Tempo Communications MM200 Manuel utilisateur