LS iS7 EtherNet/IP Manuel utilisateur

iS7 220V Auxiliary Power Option Card User Manual
1
Safety Precaution
First thank you for using our iS7 Auxiliary Power Option Board!
Please follow the following safety attentions since they are intended to
prevent any possible accident and danger so that you can use this
product safely and correctly.
Safety attentions may classify into „Warning‟ and „Caution‟ and their
meaning is as following:
Symbol
Meaning
WARNING
This symbol indicates the possibility of death or
serious injury.
CAUTION
This symbol indicates the possibility of injury or
damage to property.
The meaning of each symbol in this manual and on your equipment is
as follows.
Symbol
Meaning
This is the safety alert symbol.
Read and follow instructions carefully to avoid
dangerous situation.
This symbol alerts the user to the presence of
“dangerous voltage” inside the product that might
cause harm or electric shock.
After reading this manual, keep it in the place that the user always can
contact. This manual should be given to the person who actually uses
the products and is responsible for their maintenance.
WARNING
Do not remove the cover while power is applied or the unit is in
operation.
Otherwise, electric shock could occur.
Do not run the inverter with the front cover removed.
Otherwise, you may get an electric shock due to high voltage terminals or
charged capacitor exposure.

iS7 220V Auxiliary Power Option Card User Manual
2
WARNING
Do not remove the cover except for periodic inspections or wiring,
even if the input power is not applied.
Otherwise, you may access the charged circuits and get an electric shock.
Wiring and periodic inspections should be performed at least 10
minutes after disconnecting the input power and after checking the
DC link voltage is discharged with a meter (below DC 30V).
Otherwise, you may get an electric shock.
Operate the switches with dry hands.
Otherwise, you may get an electric shock.
Do not use the cable when its insulating tube is damaged.
Otherwise, you may get an electric shock.
Do not subject the cables to scratches, excessive stress, heavy
loads or pinching.
Otherwise, you may get an electric shock.
CAUTION
Be cautious when handling CMOS elements on the option board.
It may cause a failure due to static electricity.
When changing and connecting communication signal lines,
proceed the work while the inverter is turned off.
It may cause a communication error or failure.
Make sure to connect the inverter body to the option board
connector accurately coincided each other.
It may cause a communication error or failure.
Make sure to check the parameter unit when setting parameters.
It may cause a communication error.

iS7 220V Auxiliary Power Option Card User Manual
3
Table of Contents
Table of Contents.......................................................................................... 3
1. Introduction ........................................................................................... 4
2. Components .......................................................................................... 4
3. Installation and Wiring ............................................................................. 5
4. Option Card Standard ............................................................................10
5. Parameter .............................................................................................12
6. Function offer .......................................................................................12
6.1 Option Card Recognition ..................................................................12
6.2 Option Card Power Status LED Display...............................................13
6.3 Check Operation in Drive according to the Power Supply Status and
Communication.......................................................................................13
6.4 Jumper Use according to Communication Option ................................15
7. Troubleshooting ....................................................................................17

iS7 220V Auxiliary Power Option Card User Manual
4
1. Introduction
This user manual is standard for 220V auxiliary power option card supplying
power(5V) to the CPU in controller of IS7 to continue communication with PLC or
host controller through communication option card even if input power of IS7 is
blocked by external factors. Auxiliary power option card is designed to supply 5V
to the control board of IS7 through receiving 220V commercial power.
2. Components
-220V Auxiliary Power Option Card 1ea
-Fixed Screw 2ea
-Brass Bar 1ea
-User Manual 1ea
-
Option Card
Screw
Brass Bar
User Manual
Quantity
1
2
1
1
Item

iS7 220V Auxiliary Power Option Card User Manual
5
3. Installation and Wiring
(1) Option Module
①LED display feature
Item
220V AC Input power
Power On
Power Off
Status
220V Power input to the option card
LED On
LED off
Color
Green
Left LED only one used, the green LED lights up when 220V commercial power
is applied through terminal of this option card.
②220V AC input power
Terminal
Name
Function
L1,L2
220V Commercial Power
Supply 5V

iS7 220V Auxiliary Power Option Card User Manual
6
(2) Installation and Wiring
-Follow the procedures below for installation and wiring
①Installation
Mount a 220V auxiliary Power option card(Slot#2) dedicated to IS7.
②Wiring
Wire signal from commercial power(220V) to L1/L2 terminal block of
the option card.
220V
Commercial
Power

iS7 220V Auxiliary Power Option Card User Manual
7
-For details, see cable standard below.
<Cable Standard>
①Cable Standard : AWG20~12
②Recommended Cable Standard
Terminal
Type
Recommended Wire Size
[mm2] (AWG)
Terminal
Screw
Contact
Method
Crimp
Terminal
(Unused)
Crimp
Terminal
(used)
L1 / L2
0.75 (18)
0.5 (20)
M2
Elevator
Type
③Recommended Wire Size Crimp Terminal
④Cautions
- When you arrange control wiring by using a cable tie to work, you should
work in a place more than 15cm away from the inverter.(Otherwise, top
cover of drive may not be assembled)
- The standard of wire must be at least more than 300V and higher than 75℃
With copper wires
- When tightening the terminal block, the width of screwdriver’tip is less than
2.5mm and the thickness of screwdriver is less than 0.4mm in use.
Less than 0.4mm
Less than 2.5mm

iS7 220V Auxiliary Power Option Card User Manual
8
(3) Installation Check
- Please Proceed the following step to check whether the installation has been
done correctly.
①Shut down SV-iS7.
②Take off the upper cover of the SV-iS7 and install 220V auxiliary power
option board into the option slot.
③Connect 220V auxiliary power supply into the terminal of the option
board(L1, L2).
④Power up into SV-iS7 as well as the option.
⑤Check the option board whether the green LED light has turned on.
⑥Screw back the upper cover of the SV-iS7.
⑦Set DR30-Auxiliary Opt = ‘Yes’, using the LCD keypad.
⑧When the main power for SV-iS7 is on, the option board does not operate.
(The LED of the option board is on when the option power supply is
applied)
⑨When the main power shuts down, the relay of the auxiliary Power option
board will activate, supplying control power(5V) into the CPU.
- ‘Trip’message will show in the keypad.
- Normal operation of the motor is not possible and only communication
status through option Slot#1 will be possible.
⑩When the option board is connected and the main power of the SV-iS7
turns on the relay connection with the option board will shut down.
- Power through the option board will not be supplied and the ‘Trip’message
will automatically disappear.
- The inverter is at its ready state.
Remark
When the iS7 220V External Power option board is in operation the ‘Trip ’
message will show up in the keypad and regardless of its power rating ‘AUX
Power ON’Trip may occur. There are chances of other trips from being triggered
and the record showed up on the keypad does not necessarily show in an order in
time.

iS7 220V Auxiliary Power Option Card User Manual
9
(4) Other options mixed in use with precautions
1) The same slot op the option as shown in the table below can not be used
at the same time.
For example, Binary option card is to be used in slot#2. PLC, EXTENSION
I/O-1, EXTENSION I/O-2, Synchronization and Safety option can not be
used at the same time.
Option Slot#
Applicable Options
Option Card Slot #1
(Slot for
Communication)
RNET,
CANopen,
DEVICENET,
LONWORKS,
PROFIBUS-DP,
ETHERNET,
CC-Link
RAPIENET
Option Card Slot #2
(Slot for PLC,
Extension I/O and
so on)
PLC,
EXTENSION I/O-1,
EXTENSION I/O-2,
Synchronization,
Safety,
Binary
220V Auxiliary Power(this option)
Option Card Slot #3
(Slot for Encoder)
ENCORDER,
Position Control

iS7 220V Auxiliary Power Option Card User Manual
10
4. Option Card Standard
(1) Standard
Item
Description
Name
YA-S7M1
Auxiliary Power Option
Drive
SV-IS7 Series
Type
Option
Input Voltage
Rated Input Voltage : AC 200~230V±
10%(50/60Hz)
Output Voltage
Output to be supplied to control board of the
drive(not for external terminal)
Rated Output Voltage: DC 5V±5%
Rated Output Power: 5W±5%
External Adaptor
Not required
Cable shield ground
Terminal
Not provided
(If necessary, use F/G of drive)
Applicable Terminal
5mm Pitch, Elevator Type
LED
Only one LED shows status of auxiliary power
option.
Item
LED Power
Status
status of auxiliary power option
Color
Green(On)
Table des matières