LOGICDATA DCDinline D Manuel utilisateur

DOCUMENT VERSION 0 | JANUARY 2023
DCDinline D
Manual

DCDINLINE D MANUAL // PAGE 2
DCDinline D Operating Manual
Document Version 0 / January 2023
This document was originally published in English.
LOGICDATA Electronic & Software Entwicklungs GmbH
Wirtschaftspark 18
8530 Deutschlandsberg
Austria
Phone: +43 (0) 3462 51 98 0
Fax: +43 (0) 3462 51 98 1030
Internet: www.logicdata.net
Email: o[email protected]

DCDINLINE D MANUAL // PAGE 3
CONTENT
1 Introduction 5
1.1 Copyright 5
1.2 Royalty-Free Use of Images and Text 5
1.3 Trademarks 5
1.4 Symbols and Signal Words Used 6
2 Safety 6
2.1 General Safety Regulations and Obligations 6
2.2 Qualied Persons 7
2.3 Liability 7
3 Product 8
3.1 Description 8
3.2 Intended Use 9
4 Delivery Scope 9
5 Unpacking 10
6 Assembly 10
6.1 General Assembly 10
6.1.1 Actuator Dimensions 11
6.1.2 Installation Options 11
6.1.3 Installation Tolerances 12
6.1.4 Default Settings 13
6.2 Assembly “Thick End Up” Variant 13
6.2.1 Attaching the Middle Tube 13
6.3 Assembly “Thick End Down” Variant 15
6.4 Motor Side Interface 16
6.5 Flange Side Interface 17
7 Software-Dependent Functions 17
8 Intelligent System Protection (ISP) 18
9 Disassembly 18

DCDINLINE D MANUAL // PAGE 5
1 INTRODUCTION
The product documentation consists of this manual and a datasheet.
This document is intended to enable the assembly personnel to work safely with the DCDinline D actuator.
The assembly personnel must therefore always have the complete documentation available. The document
must be complete and in a perfectly legible condition. Follow the instructions in this document to avoid
hazards and to prevent damage to the DCDinline D.
The information in this document has been compiled with great care. We strive to ensure the accuracy and
completeness of the content by revising it and updating it regularly, however, no guarantee can be given for
its accuracy and completeness.
1.1 COPYRIGHT
© January 2023 by LOGICDATA Electronic und Software Entwicklungs GmbH. All rights reserved, except
for those listed in Chapter 1.2 Royalty-free use of images and text on page 5.
1.2 ROYALTY-FREE USE OF IMAGES AND TEXT
After purchase and full payment of the product, all text and images in Chapter 2 “Safety”, may be used
free of charge by the customer. They should be used to prepare end user documentation for Height-
Adjustable Table Systems. The license does not include logos, designs, and page layout elements belonging
to LOGICDATA. The transfer of this license to third parties without permission from LOGICDATA is exclu-
ded. Full ownership and copyright of the text and graphics remain with LOGICDATA. Texts and graphics are
oered in their current state without warranty or promise of any kind.
1.3 TRADEMARKS
Documentation may include the representation of registered trademarks of goods or services, as well as
information about copyright or other proprietary expertise of LOGICDATA or third parties. In all cases, all
rights remain exclusively with the respective copyright holder. LOGICDATA® is a registered trademark of
LOGICDATA Electronic & Software GmbH in the USA, the European Union, and other countries.

DCDINLINE D MANUAL // PAGE 6
1.4 SYMBOLS AND SIGNAL WORDS USED
Safety Notices contain both symbols and signal words. The signal word indicates the severity of the hazard.
CAUTION Danger of material damage and possible additional low risk of injury.
A safety notice with the signal word „Caution“ indicates a hazardous situation
which, if not avoided, could result in minor or moderate injury.
NOTICE The label NOTICE indicates a situation that will not lead to personal injury, but could
lead to damage to the product or the environment.
NOTICE Damage due to electrostatic discharge (ESD)
2 SAFETY
2.1 GENERAL SAFETY REGULATIONS AND OBLIGATIONS
In general, the following safety regulations and obligations apply when handling the product:
• The DCDinline -DR actuator may only be operated in a clean and perfect condition.
• Do not remove, change, bridge or bypass any protection, safety or monitoring equipment.
• Do not convert or modify the DCDinline D actuator without written approval
from LOGICDATA.
• In the event of malfunction or damage, the DCDinline D actuator must be
replaced immediately.
• Do not attempt to repair the acuator yourself.
• Hardware replacement is only allowed in a de-energized state.
• For the operation of the system, the national worker protection conditions and the
national safety and accident prevention regulations apply.

DCDINLINE D MANUAL // PAGE 7
2.2 QUALIFIED PERSONS
The DCDinline D may only be installed and commissioned by qualied persons who are authorized for instal-
lation planning, installation, commissioning or maintenance/servicing and who have read and understood
the DCDinline D documentation. Qualied persons have the necessary expertise to test, assess and manage
electrical and mechatronic products and systems in accordance with the generally accepted standards and
guidelines of electrical engineering and furniture manufacturing through their education, work experience
and recent professional activity. They know and adhere to the basic regulations on occupational safety and
accident prevention and the basic norms and specialist standards applicable to the specic application.
2.3 LIABILITY
The products comply with the applicable state of the art health and safety regulations. Nevertheless, dan-
gers can result from incorrect operation or misuse.
LOGICDATA is not liable for damages caused by:
• Improper use of the products
• Disregard of the documentation
• Unauthorized changes to the products
• Improper work on and with the DCDinline D
• Operating a damaged product
• Wear parts
• Improperly performed repairs
• Unauthorized, improper change of operating parameters
• Disasters, external inuence and force majeure
Responsible for the LOGICDATA products in the specic application and compliance with the relevant di-
rectives, standards and laws is the manufacturer of the height-adjustable tables in which the LOGICDATA
products are installed. LOGICDATA shall not be held liable for any damage that is directly or indirectly at-
tributable to the delivery, performance or use of this document. Each reseller must take into account the
relevant safety standards and guidelines for his product in which the DCDinline D is installed.

DCDINLINE D MANUAL // PAGE 8
3 PRODUCT
3.1 DESCRIPTION
The DCDinline D is an actuator for electrically height-adjustable tables. It is installed by the customer in
a column for electrically height-adjustable tables. It is controlled by a control unit from LOGICDATA, to
which dierent hand switches can be connected. Several drives can be operated synchronously on one con-
trol unit.
Fig. 1: DCDinline D
1 Attachment point on motor end (screws and rubber discs provided)
2 Connection cable
3 Motor
4 Attachment point middle tube with installation variant – thick end up
5 Attachment point middle tube with installation variant – thick end down
6 Flange attachment point
2
3
4
5
6
1

DCDINLINE D MANUAL // PAGE 9
3.2 INTENDED USE
The DCDinline D actuator may only be installed in telescopic tubes to adjust electrically height-adjustable
tables and used for this purpose exclusively. The intended use is to adjust the table height electrically. Only
control units from LOGICDATA, which are parameterized for the DCDinline D, may be used for this purpose.
The actuators must be assembled, commissioned and functionally checked by qualied personnel. Any
other use that does not conform to the intended use will result in the loss of warranty and warranty claims.
The basic function is the upward and downward movement (of a table top). This function can be executed
with suitable hand switches from LOGICDATA.
NOTICE Permissible drive loads and speeds always refer to the product DCDinline D and not to
the additional load on the table system. The reseller must take additional loads such
as e.g. friction forces, the deadweight of the table components and torque loads into
consideration. The newly determined permissible load must be specied in the parent
documentation of the nal product.
4 DELIVERY SCOPE
The standard scope of delivery for the DCDinline D actuator consists of the following components:
Fig. 2: Delivery scope
Standard delivery scope
1 DCDinline D actuator
2 Two mounting screws incl. rubber disks (LOG-PRT-SD-MOUNTINGSCREW)
12

DCDINLINE D MANUAL // PAGE 10
5 UNPACKING
The DCDinline D actuator is packaged in a carton.
NOTICE Ensure proper ESD handling during unpacking. Errors that can be attributed to
electrostatic discharge will void warranty claims
To unpack, proceed as follows:
1. Remove the packaging material from the drive components.
2. Check the contents of the package for completeness and damage.
3. Provide the operating manual to the operating personnel.
4. Dispose of the packaging material.
NOTICE Dispose of the packaging material in an environmentally friendly manner (separate
the plastic parts and the cardboard by type).
6 ASSEMBLY
6.1 GENERAL ASSEMBLY
NOTICE Before assembly and operation, the DCDinline D must be acclimatised to the ambient
conditions.
NOTICE Ensure proper ESD handling throughout the installation. Errors that can be attributed
to electrostatic discharge will void warranty claims.
Table des matières
Autres manuels LOGICDATA Mobilier d'intérieur
























