0 BEFORE INSTALLATION ...................................................................................................................4
1 INTRODUCTIONS ...............................................................................................................................5
1-1 FEATURES.......................................................................................................................................5
1-2 SPECIFICATIONS ..............................................................................................................................6
1-3WIRING DIAGRAM ............................................................................................................................7
1-4 INSTALLATION ..................................................................................................................................8
1-5 PANEL INTRODUCTION....................................................................................................................11
2 OPERATIONS....................................................................................................................................12
2-0 EDX SYSTEM................................................................................................................................12
2-1 FUNCTIONS ...................................................................................................................................14
2-2 INITIALIZATION................................................................................................................................15
2-3 DMX START CHANNELADDRESS SETTING ......................................................................................15
2-4 ZONE SETTING ..............................................................................................................................16
2-5 PARTITION SETTING .......................................................................................................................17
2-6 ID NUMBER SETTING .....................................................................................................................22
2-7 FADE TIME SETTING.......................................................................................................................22
2-8 SYSTEM CLOCK SETTING ...............................................................................................................23
2-9 TIMER ON/OFF.............................................................................................................................23
2-10 DIMMING /SWITCH /FLUORESCENT MODE SETTING........................................................................24
2-11 DISPLAY SYSTEM TEMPERATURE ..................................................................................................25
2-12 DISPLAY CURRENT LOAD..............................................................................................................25
2-13 SET TIMER ..................................................................................................................................26
2-14 SCENE SETTING ..........................................................................................................................27
2-15 SCENE RECALL............................................................................................................................28
2-16 MEMORY &BUTTON LOCK/UNLOCK FUNCTION..............................................................................28
2-17ADJUST AND VIEW DIMMING VALUE...............................................................................................28
2-18 PANEL LED ON/OFF SETTING........................................................................................................29
2-19 DIMMING CURVE SETTING............................................................................................................30
2-20 ENABLE/DISABLE PARTITION FUNCTION ........................................................................................30
2-21 CHECK SOFTWARE VERSION........................................................................................................31
2-22 ENABLE/DISABLE IR REMOTE CONTROL .......................................................................................31
2-23 ENABLE/DISABLE SC5/6 OVERLAP SCENE FUNCTION....................................................................32

EDX-607A [EUM-G] 4
0 Before Installation
1. The setting of dimmer or non-dimmer mode:
The dimming/non-dimming (switch) mode should be preset before the lamps/loads being connected to
the devices. Please refer to “Dimmer/Switch Mode Setting” in this manual.
2. Current Loading Precaution:.
Please keep adequate ventilation. If the machine’s internal temperature is over 65°C, the device will
stop output.
The maximum output of each channel is 4A. The maximum output of the 6 channels in total is 8A .
3. Instruction of power/ load wiring:
Connector size range AWG 22-14
Use Copper Conductors Only, 60/75C, Tighten To 12 pound-inches.
4. Suggested Environment:
Ambience Temperature: under 35°C
Humidity: 40% ~ 80%
5. About wiring:
Please check EDX/DMX-512 wiring guide on Lite-Puter’s website:
http://www.liteputer.com.tw/tech_guide.asp

EDX-607A [EUM-G] 5
1 Introductions
1-1 Features
1. 6 channels. The maximum output of each channel is 4A; the maximum output in total is 8A .
2. The master panel can store 12 scenes, display 12 channels dimming value, and transmit 12
channels DMX-512 signal.
3. IR remote controller (optional) can recall 6 scenes, adjust any channel’s dimming level, and
edit 6 scenes directly. User can also view current zone number and set fade in/fade out time by
IR remote controller
4. C1, C2, C3 liner dimming curve.
5. Fade in/fade out time setting.
6. Timer control can execute preset lighting scenes automatically (24hours).
7. Each channel can be set as dimming, switch or fluorescent mode.
8. Display system temperature and detect temperature automatically. When the internal
temperature is over 70°C, it will alert and limit the output to 50%. Over 75°C it will stop output
automatically.
9. Display total current. If total current is over 25A, it will switch off automatically and press【OFF】
to restart the device . If total current is over 20A, it will limit the output to 12A and press any
button to restart the system.
10. Can be connected to scene control panels (ECP series).
11. Lock/unlock.

EDX-607A [EUM-G] 6
1-2 Specifications
Power: AC 100 –240V, 50/60Hz
Output: 4A per channel, total 8A . Leading edge (forward phase) dimming control.
Protocol: DMX-512/ EDX (RS-485)
Dimension: 212 (W) x 118 (H) x 60 (D)mm
Weight: 0.88 KG
Fuse:PCB No.: QB18B F1 (Resistive fuse 20A, 250V)
F2 (Resistive fuse 1A, 250V)
F3 (Resettable fuse)

EDX-607A [EUM-G] 7
1-3 Wiring Diagram

EDX-607A [EUM-G] 8
1-4 Installation
1. Please refer chapter 2-10 to set switch mode before connecting no-dimmable lamps. Non-dimmable
lamps might be damaged by dimming mode.
2. Please make sure the ambience temperature is under 40°C.
3. Please ensure that wall-mounted area has at least 75mm in depth.

EDX-607A [EUM-G] 9