Lightwave JSJSLW400 Manuel utilisateur

Connect Series
www.lightwaverf.com
Dimmer Switch (1 Gang)
Model No. JSJSLW400
Instruction Manual
Version 2

EC DECLARATION OF CONFORMITY
Responsible Authority:
LightwaveRF PLC,
Innovation Campus Birmingham
Faraday Wharf
Holt Street
Birmingham
B7 4BB
Tel: +44 (0)121 250 3625
Model Number(s): JSJSLW400
Description: Dimmer Switch
Directives this equipment
Complies with: 2006/95/EC The Low Voltage Directive N/A
2004/108/EEC The Electromagnetic Compatibility Directive
1999/5/EC R&TTE Directive
93/68/EEC CE Marking Directive
Standards Applied in order to verify compliance
Safety: BS EN 60730-1: 2011
Health:
R&TTE: EN 301 489-1 V1.9.2: (2011-09), EN 301 489-3 V1.4.1: (2002-08)
EN 300 220-1 V2.1.1: 2006, EN 300 220-2 V2.1.2: 2007
EMC: EN 301 489-1 V1.9.2: (2011-09), EN 301 489-3 V1.4.1: (2002-08),
EN 55022: 2010, EN 61000-3-2: 2006 +A1: 2009 +A2: 2009 Class A,
EN 61000-3-3: 2008, EN61000-4-2: 2009,
EN 61000-4-3: 2006 +A1: 2008 +A2: 2010, EN 61000-4-4: 2012,
EN 61000-4-5: 2006, EN 61000-4-6: 2009, EN 61000-4-11: 2004
For and on behalf of LightwaveRF PLC
----------------------------------------
Name J Shermer
Position Managing Director

Get Started
What do I need?
How do I get started?
To install the dimmer, you will need to remove
and replace the existing lightswitch. This is
usually straightforward, but you must ensure that
there is a suitably deep housing (backbox) and
understand how to safely turn o the electricity
supply. You will also need suitable electrical
screwdrivers.
Please refer to the following installation and
setup instructions. This will guide you, step by
step, through the installation and setup process.
Help video & further guidance
For additional guidance, and to watch a video
that will help guide you through the installation
process, please visit the support section on
www.lightwaverf.com

Amber LED.
When illuminated,
dimmer is o.
‘On’ button.
Hold to raise light
level.
‘O’ button.
Hold to lower light
level.
Blue LED. When
illuminated, the
dimmer is on.
Overview
Installation
IMPORTANT: All LightwaveRF products can be legally DIY installed in your
own home; however, if in doubt, always consult a qualified electrician or
heating engineer. It is important to install this product in accordance with
the following instructions. Failure to do so may void your warranty.

Switched live
(live out)
Screw
mounting
hole
Live in
2-Way
switching
connection
Installation
IMPORTANT: If conducting an insulation resistance test, all LightwaveRF
products must be disconnected from the mains, or damage will occur.

Quick Start Guide
Installation
1. IMPORTANT: Turn o the mains electrical supply.
2. Ensure that the wall (back) box has a minimum depth of 35mm.
3. Remove and disconnect the existing lightswitch (if applicable). It may be
useful at this point to mark out or take a photograph of the connections to
the existing switch so that the correct wires can easily be transferred to the
new dimmer. Some existing wiring configurations can be complex so take
care.
4. Gently remove the dimmer faceplate by inserting a screwdriver into one
of the bottom slots and lifting away from the unit as shown.

Installation
5. Connect the wiring as per the wiring diagram on the following page.
Ensure that the terminals are properly tightened and that no bare wire is
visible. Be aware that existing wiring circuits are not always correctly
coloured, and that there may be other wired connections present in the back
box; if in doubt, always seek the advice of a qualified electrician.
NOTE: LightwaveRF dimmers do NOT require a mains neutral wire to be
connected; they only require ‘live in’ and ‘switched live out’.
7. Screw the dimmer switch to the
mounting box and ensure that the
screws are suciently tight to support
the product, but do not over tighten as
this may cause the chassis to bend.
Ensure that the plastic spacer is
correctly aligned and that no wires are
trapped between the dimmer switch and
the back box.
6. Any earth wires present must be attached either to the earth terminal
located in the back box or capped with a strip connector. The dimmers are
double insulated so are not required to be earthed directly.

Installation
Signal cable connection
for use with LightwaveRF
2-Way Dimmer only
(LOW VOLTAGE: Do not
connect to live mains!)
Earth wire connects
to terminal in back
box (can be capped
o instead if no
terminal present)
Live wire In. This
should be brown
or red in colour.
Switched live
Wire Out. This
should be
blue or black
in colour.
The switched live may
be marked by brown/red
tape to emphasise that
it is not a neutral wire.

Installation
8. Replace the plate – a ‘click’ sound
should be heard to signify that the
plate has been correctly replaced.
• It is recommended that LightwaveRF devices be positioned at least 30cm
apart in order to prevent the risk of any radio conflict that could disrupt
remote operation.
• Suitable lamps must be used with the dimmer or it will not function
correctly. See next section for compatibility information.
Important things to consider
• In a multigang dimmer, to be able to
operate any gang, mains electricity
must always be connected to all of the
dimmer terminals.

Installation
• Up to six 2-way dimmers (six gangs) can be connected to a standard
LightwaveRF dimmer switch. Each 2-way can be connected directly to the
standard dimmer, or connected to each other in a ‘daisy-chain’. This
provides an alternative to using intermediate switches (maximum cable
length of 100m)
• The 2-way dimmers use standard 3-core connecting wires; however,
because they are electronic dimmers, they utilise one of the cores as a
signal cable (‘S’) running between the dimmers (as shown on the diagram).
This is low voltage only and should not be connected to 230V mains.
Important: Never install and run power to a LightwaveRF 2-way dimmer
switch before first installing and connecting the counterpart standard
LightwaveRF dimmer. Serious damage could be caused to the unit.
Connecting to a 2-Way Dimmer
• Any LightwaveRF dimmer switch (and any gang in a multigang dimmer)
can be used in conjunction with a LightwaveRF 2-way dimmer to perform
2-way switching. For full instructions on how to install a 2-way dimmer,
please consult the instruction booklet for the 2-way dimmer.
Important: The dimmer must be used with a LightwaveRF 2-way dimmer
and cannot be used with another LightwaveRF dimmer or a standard light
switch. This will cause damage to the dimmer.
Table des matières
Manuels Équipement d'éclairage populaires d'autres marques

Qazqa
Qazqa Suplux SL 3 Black 103062 Manuel utilisateur

Commercial Electric
Commercial Electric 54568141 Manuel utilisateur

CREE LIGHTING
CREE LIGHTING 304 Series Manuel utilisateur

Goobay
Goobay 49867 Manuel utilisateur

ECOMAN ITALIA
ECOMAN ITALIA LED T8 Manuel utilisateur

Alkalite
Alkalite Krypton KT-81 Manuel utilisateur