LG PSF1032A Manuel utilisateur

P/No.: MFL62883403
MODEL : PSF1032A
User Manual
※IMPORTANT
• Please read this installation manual completely
before installing the product.
• Installation work must be performed in
accordance with the national wiring standards by
authorized personnel only.
• Please retain this installation manual for future
reference after reading it thoroughly.

What is PLS?
Plasma Lighting System
PLS is a non-electrode lighting device using the new concept
of plasma illumination by microwave.
PLS is an economic lamp with high efficiency and long life
span.
- Power consumption and maintenance cost are lower compared to the
existing lighting (Based on number of installations)
- With the ballast internally installed, there is no need to separately
purchase the ballast.
Optimal lighting environment
- PLS provides optimal lighting environment with high illumination even for
the wide area. (Refer to the following distribution curve of luminous
intensity.
- The level of light fading after long use is minimal.
Nature friendly lighting
- Simulates natural and high color rendering lighting.
- Minimizes radiation of ultraviolet and infrared ray.
- No environmentally hazardous material (Mercury, lead, cadmium etc.)
Features
- LEGEND (D-PLANES)
●Distribution curve data of luminous intensity
(Based on average beam angle)
- CONE L X LEVELS
2

3
Contents Safety precaution
4~7
Installation criteria and example
10~12
Installation method
8
Check before requesting for service
13
Component and name
9
Installation and power connection 4-5
sing and cleaning 6-7
Product specification
14
Product warranty 15
Customer card 16
About customer service 17

4
Safety
precaution
Installation
and power
connection
Use the trolley when moving the product because
it is heavy.
• It can cause injury or product damage when it drops.
Do not install the product in the place where it is
always moist.
• It can cause a fire.
Do not install the product where the product can
be submersed.
• It can cause an electric shock.
Do not install the product where the surface is
not even.
• It can block the inlet/outlet installed below the
power supply and damage the system.
•The meaning of the symbol shown on product and this manual are
as follows.
• This symbol shows the detail and operation that can result in
dangerous situation. Read carefully and follow the direction
with this symbol to avoid any dangerous situation.
• This symbol shows the potential situation with electric shock
under specific condition.
• Potential for major injury or human death
when directions are violated
• Potential for minor injury or product
damage when directions are violated
WARNING
CAUTION
WARNING
Do not put any objects that block the inlet/outlet to
ensure space to cool the product.
• It can cause problems to the product.
Less than
95% humidity

5
WARNING
Configure the switchboard to
electric capacity (7A) for each set.
• Always ground the product as it can
cause an electric shock or a fire.
• When using SSR, install the
product according to 20A capacity
specification per set.
Use the product at rated
specification.
• It can cause a fire or product
damage.
Firmly fixate the product
considering the installation
support, product weight (21kg)
and the vibration so that it does
not shake. [Always use fixating bolt
M8, spring washer and nut.]
• It can cause an injury if the
product falls.
21kg
After installing and fixating the
product, do not block the product
with alien material (Vinyl, silicon
etc.) as shown on the left.
• It can block the inlet/outlet installed
below the power supply and
damage the system.
Do not install the product
where it not ventilated well.
• It can cause heating of the
product or a fire.
Keep 30cm of clearance
from the case to the wall to
safely use the product.
• It can cause heating of the
product.
When laying down the product on
the floor, put it in the same
direction as shown in the picture.
• If not laid as shown in the picture, it
can cause product damage.
CAUTION
Current
capacity
7A
Within
±10%
Please do earth work.
• It can cause electric shock if not
do the earth work
Install earth leakage breaker and
exclusive switch.
• It can cause fire and electric shock
if not installed.
Do not use any heating device
or flammable material within
1m of the product.
• It can cause a fire or an
explosion.
Electric work has to be done by
certified technicians by technical
regulation on electric equipment or
indoor wiring specification and
regulation, and this installation guide.
A specific circuit has be used.
• It can cause fire and electric shock if
power capacity is inadequate or
electric work is faulty
Earth leakage
breaker
Exclusive
switch

6
Safety
precaution
Use and
Cleaning
Do not disassemble or reconfigure the product.
Do not use the product for underwater lighting.
(Underwater lighting display, exploration,
fishing, event etc.)
• It can cause a fire or an electric shock.
Never disassemble the main unit of the product.
• It can cause an electric shock from high voltage
electricity flowing inside the product.
• When the cover is arbitrarily disassembled, it can
cause an injury from leakage of microwave.
• Never take off the external cover unless done by the
service technician.
Never stare at the lamp when the lighting is
turned on.
• It can cause visual disorder due to the strong light.
Do not use the product for purposes other than
lighting. (Warning food, drying clothe)
• It can cause a fire.
WARNING
If the PLS is submersed in water, use the
product after repairing the product.
• It can cause a fire or an electric shock.
Service

7
When the lamp is
abnormally turned off, do
not disassemble the
product, and always
request for service to the
service center.
• It can cause an electric
shock or problems to the
product.
Be careful not to let any
alien object (Pin, coin, steel
wire) get into the inlet/outlet
and internal/external hole on
the case.
• It can cause a fire or an
electric shock.
Do not use the product
when dropped or when
impact is applied.
• It can cause problems to
the product.
Do not use the product with
the cover on the exterior of
the product.
• It can cause a fire or an
electric shock.
When cleaning the
product, never spray water
directly on the main unit of
the product.
• It can cause a fire or an
electric shock.
When touching hot parts
(Cover glass, reflector etc.),
always wear safety gloves.
• Because the product is hot
while or after it is operating,
it can cause a burn.
WARNING
CAUTION

8
Installation
method
Before installing…
– This model (PSF1032A) is designed to be installed outdoors and
supports day to day water proofing.
– To prevent the product from falling by wind or other external force, use
the bolt and nut of M8 or above.
– Be careful not to let other objects interfere with product from cooling
and also be careful not to block the inlet/outlet when installing the
product.
– Installing the product in an environment that exceeds the usable
temperature and humidity can cause unexpected issues. Therefore
always consult with LG Electronics before installing the product.
– Installing the product in locations where chemicals such as TCE series
or chlorine gas are used or locations where vibration is excessive can
cause unexpected issues. Therefore always consult with LG Electronics
before installing the product.
– When using the product in highly dusty area, the illumination can be
reduced due to the dust. Therefore periodically clean the product and
do not install the product where metallic dust is generated.
– Install at least 1m from the ground clearance distance must be
maintained.
– The mark means min. distance from PLS to lighted object when install
the PLS, check the distance from PLS on the optical axis of PLS.
3m
1. Follow regulations of government agency for technical standard and
electric power company's guide regarding regulations on equipment
and wiring.
CAUTION
2. Do stated earth work when installing PLS
•
Do earthwork of PLS. Do not connect earth wire
with gas pipe, water pipe, lightning rod or
telephone line. It can cause electric shock as it
makes earthwork incomplete.
WARNING
WARNING
•
By the regulation and this installation guide,
electric work using a specific circuit must be done
by certified electric technician. It can cause fire or
electric shock if capacity of power supply circuit is
insufficient or faulty.

9
Component
and name
Product size
( nits : mm)
Case, pper
Glass, Cover
Cover, Top
Case, Lower
Bolt, Aiming
Angle
Component and name
Cover, Front
Tilt, Swivel
Power Supply
Cover, Side
Cover, Back
Cable, High Voltage
Power Cord (Plug-less)
※Accessories in box
Item
SER MAN AL
No. (EA)
1

10
Installation
criteria and
example
Power condition and switchboard
configuration for PLS installation
• Because the power consumption per 1 set of PLS is high,
the cross sectional area of the switchboard must
appropriately be applied, and for stable operation, one
control switch must be installed for each set.
• Grounding requires more than 3 grounding points and must
be wired for safety purposes.
Note)
MCCB: Molded Case Circuit Breaker
ELB: Earth Leakage Circuit Breaker
se rate sensitivity current (Break current) of 30 [mA]
MS: Magnetic Switch ( sed when applying GPS or auto flash device)
* PLS is not equipped with a terminal block. For installation, please get professional
assistance.
- Terminal Block Specification
(a) Rated Voltage: 250V or above
(b) Rated Power: 10A or above
(c) 3 way bolt fastening type
- After connecting power line to the terminal block, ensure that the power line makes
secure contact with fastening bolt or clamp and the power line is securely fastened.
PLS switchboard
(When installing 6 sets)
Apply
14.0
mm2
or above
MCCB
75A or
above
Apply 2.0 mm2
or above for
each line
Recommended to
apply ELB, MS
capacity of 10A
• After wiring power line to terminal box, check if the line touches tightening bolt or
clamp or is being forced.
• se regulated electric wire so connecting part of terminal is knocked out by external
force. It can cause fire if connecting part is fixed tightly as it generates heat.
• Wire power line after ring terminal work. It can cause fire and failure of electric parts.
• Check Neutral status when installing main power
• Ending part of PLS has to be waterproof when connecting it to terminal.
WARNING
Autres manuels pour PSF1032A
1
Table des matières
Manuels Mettre en lumière populaires d'autres marques

Guangzhou Yinhe Lighting&Sound Equipment Factory
Guangzhou Yinhe Lighting&Sound Equipment Factory NE-204 Manuel utilisateur

LIVARNO home
LIVARNO home 375304 2101 Instructions originales

Cameo
Cameo CLQS40WW Manuel utilisateur

Leviton
Leviton Ellipsoid 5/50 Manuel utilisateur

Monacor
Monacor img Stage Line PARL-56PDX/CR Manuel utilisateur

Vector
Vector SL3AKV Manuel utilisateur

EuroLite
EuroLite Akku flat light 1 Manuel utilisateur

Commercial Electric
Commercial Electric SPTM-1401 Manuel utilisateur

Vision & Control
Vision & Control SLB-500-W5K7-P-SL Manuel utilisateur

Teknik
Teknik FLEXI Manuel utilisateur

Craftsman
Craftsman CMXLSB10 Manuel utilisateur

EuroLite
EuroLite LED SLS-144 UV Floor Spot Manuel utilisateur