Safety Precautions
.........................................................................................3
Installation of Indoor, Outdoor Unit .............................................................7
1) Selection of the best location................................................................................................................................7
2) Indoor Unit Installation .........................................................................................................................................10
3) Outdoor unit installation .......................................................................................................................................10
4) Refrigerant amount ..............................................................................................................................................10
5) Installation method procedure..............................................................................................................................11
6) Preparation of installation parts and tools ...........................................................................................................12
7) Preparation of piping............................................................................................................................................13
8) Connection of piping ............................................................................................................................................14
9) Precautions in bending ........................................................................................................................................14
10) Connecting the cable to the indoor unit.............................................................................................................15
11) Connecting the piping to the outdoor unit..........................................................................................................16
12) Connecting the cable to the outdoor unit...........................................................................................................16
13) Power supply and wiring ....................................................................................................................................17
14) Vacuum drying of the connecting pipes and the indoor unit..............................................................................18
15) Form the pipe.....................................................................................................................................................19
Final Check and Test Run ...........................................................................................20
OUT-LINE OF INSTALLATION
Installation Tools............................................................................................6

Safety Precautions
Installation Manual 3
To prevent injury to the user or other people and property damage, the following instructions
must be followed.
Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness
is classified by the following indications.
Meanings of symbols used in this manual are as shown below.
WARNING
CAUTION
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage.
WARNING
Be sure not to do.
Be sure to follow the instruction.
Safety Precautions
Installation
Install the panel and the cover of
control box securely.
• There is risk of fire or
electric shock.
Always install a dedicated
circuit and breaker.
• Improper wiring or
installation may cause fire or
electric shock
Use the correctly rated breaker
or fuse.
• There is risk of fire or
electric shock.
Do not use a defective or
underrated circuit breaker. Use
this appliance on a dedicated
circuit.
• There is risk of fire or
electric shock.
For electrical work, contact the
dealer, seller, a qualified
electrician, or an Authorized
Service Center.
•
Do not disassemble or repair
the product. There is risk of
fire or electric shock.
Always ground the product.
• There is risk of fire or
electric shock.

4Floor Standing type Air Conditioner
Safety Precautions
Do not modify or extend the power cable.
• There is risk of fire or electric shock.
Be cautious when unpacking and installing the
product.
•
Sharp edges could cause injury. Be especially
careful of the case edges and the fins on the
condenser and evaporator.
For installation, always contact the dealer or an
Authorized Service Center.
• There is risk of fire, electric shock, explosion,
or injury.
Do not install the product on a defective
installation stand.
• It may cause injury, accident, or damage to
the product.
Be sure the installation area does not
deteriorate with age.
•
If the base collapses, the air conditioner could fall with
it, causing property damage, product failure, and
personal injury.
Do not let the air conditioner run for a long time when
the humidity is very high and a door or a window is
left open.
• Moisture may condense and wet or damage
furniture.
Do not store or use flammable gas or combustibles
near the product.
• There is risk of fire or failure of product.
Operation
n
i
l
o
s
a
G

Safety Precautions
Installation Manual 5
Always check for gas (refrigerant) leakage after
installation or repair of product.
• Low refrigerant levels may cause failure of
product.
Install the drain hose to ensure that water is
drained away properly.
• A bad connection may cause water leakage.
Keep level even when installing the product.
• To avoid vibration or water leakage.
Do not install the product where the noise or hot air
from the outdoor unit could damage the
neighborhoods.
• It may cause a problem for your neighbors.
Use two or more people to lift and transport the
product.
• Avoid personal injury.
Do not install the product where it will be
exposed to sea wind (salt spray) directly.
• It may cause corrosion on the product.
Corrosion, particularly on the condenser and
evaporator fins, could cause product
malfunction or inefficient operation.
CAUTION
90˚
Installation

Installation
Floor Standing type Air Conditioner
6
Installation Tools
Figure FigureName
Screw driver
Electric drill
Measuring tape, Knife
Hole core drill
Spanner
Torque wrench
Ohmmeter
Hexagonal wrench
Ammeter
Gas-leak detector
Thermometer,
Horizontal meter
Flaring tool set
Manifold gage Vacuum pump
Name
R-22
Installation

7
Installtion Manual
Installation of Unit
Installation of Unit
1. Indoor unit
• There should not be any heat source or
steam near the unit.
• There should not be any obstacles to
prevent the air circulation.
• A place where air circulation in the room
will be good.
• A place where drainage can be easily
obtained.
• A place where noise prevention is taken
into consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows
from the wall, ceiling, or other obstacles.
• The indoor unit must keep the
maintenance space.
2. Outdoor unit
• If an awning is built over the unit to prevent
direct sunlight or rain exposure, be careful
that heat radiation from the condenser is
not restricted.
• There should not be any animals or plants
which could be affected by hot air
discharged.
• Ensure the spaces indicated by arrows
from the wall, ceiling, fence or other
obstacles.
mc5
m
c
04
m
c
5
mc0
0
1
More than
50cm
r
o
e
c
n
e
F
s
e
l
c
at
s
bo
More than 100cm
More than 50cm
MMoorree tthhaann
3300ccmm
More than
50cm
S
f
o
or
n
u
Selection of the best location

Installation
Floor Standing type Air Conditioner
8
1.
Air conditioners should not be installed in areas where corrosive gases, such as acid or alkaline gas, are produced.
2. Do not install the product where it could be exposed to sea wind (salty wind) directly. It can result corrosion
on the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunc-
tion or inefficient performance.
3. If outdoor unit is installed close to the seaside, it should avoid direct exposure to the sea wind. Otherwise it
needs additional anticorrosion treatment on the heat exchanger.
1.
If you can’t meet above guide line in the seaside installation, please contact LG Electronics for the additional anticorrosion treatment.
2. Periodic ( more than once/year ) cleaning of the dust or salt particles stuck on the heat exchanger by using water
3) Installation guide at the seaside
3.1 Selecting the location(Outdoor Unit)
1) If the outdoor unit is to be installed close to the seaside, direct exposure to the sea wind should be avoided.
Install the outdoor unit on the opposite side of the sea wind direction.
2) In case, to install the outdoor unit on the seaside, set up a windbreak not to be exposed to the sea wind.
3) Select a well-drained place.
• It should be strong enough like concrete to prevent
the sea wind from the sea.
• The height and width should be more than 150% of
the outdoor unit.
• It should be keep more than 70 cm of space
between outdoor unit and the windbreak for easy
air flow.
Sea wind Sea wind
Sea wind
Windbreak
CAUTION

Installation of Unit
Installation Manual 9
4. Piping length and the elevation
CAUTION:
• Capacity is based on standard length and maximum allowance length is on
the basis of reliability.
• Oil trap should be installed every 5~7 meters.
5/8" 1/4" 30 10
5/8" 1/4" 30 10
5/8" 3/8" 30 10
PIPE SIZE
MODEL
GAS SIDE LIQUID SIDE
Max.
Length
A (m)
Max.
Elevation
B (m)
A
B
Indoor unit
Outdoor unit
HP-C3063EC0
HP-C306KA0
HP-C366TA0
3/4" 3/8" 30 15
HP-C508TA1
HP-C608TA0
3/4"
1/2" 30 15

10 Floor Standing type Air Conditioner
Installation of Unit
200mm
70mm 70mm
mm09
Wall
Core Drill
Tilt
Cut if necessary
More than 15mm
Wall
Plastic tube
(Bushing)
INSIDE OUTSIDE
1. The mounting floor should be strong and solid
enough to prevent it from vibration.
2. Drill the piping hole with 70mm diameter hole-
core drill at either the right or the left of indoor
unit. The hole should be sightly slant to the
outdoor side.
3. Insert the plastic tube through the hole.
4. Cut the extruded outside part of the plastic
tube, if necessary.
1. Install the outdoor unit on the concrete or any solid base securely and horizontally by securing it
with bolts (Ø12mm) and nuts.
2. If there is any vibration transmitted to the building, mount the rubber underneath the outdoor unit.
Before shipment, this air conditioner is filled
with the rated amount of refrigerant including
additional amount required for air-purging,
subject to 7.5m piping length. (The rated
amount of refrigerant is indicated on the name
plate.) But when the piping length exceeds 7.5
meters, additional charge is required according
to the following table.
Example) 30K
In case of 10m long pipe(one-way), the amount
of refrigerant to be replenished is:
(10 - 7.5) x 30 = 75g
(Unit: g)
REFRIGERANT CHARGE
MODEL
HP-C366TA0
HP-C306KA0
HP-C3063EC0
HP-C508TA1
30g/m
50g/m
40g/m
60g/m
Indoor unit Installation
Outdoor unit Installation
Refrigerant amount
HP-C608TA0 60g/m
Ce manuel convient aux modèles suivants
4
Table des matières
Autres manuels LG Climatiseur

LG
LG ZBNQ09GL1A0 Guide produit

LG
LG LT1036CER Manuel utilisateur

LG
LG Multi V 5 Manuel utilisateur

LG
LG E10SV5 Manuel utilisateur

LG
LG LP6010ER Manuel utilisateur

LG
LG AUUQ18GH0 Manuel utilisateur

LG
LG MA12AHV Manuel utilisateur

LG
LG HSN09IPX Manuel utilisateur

LG
LG ARNU073TRC2 Manuel utilisateur

LG
LG W121CE SL0 Manuel utilisateur

LG
LG AP-Z Series Manuel utilisateur

LG
LG Duct series Manuel utilisateur

LG
LG ACHH Series Manuel utilisateur

LG
LG AMNW Series Manuel utilisateur

LG
LG LW1813HR Manuel utilisateur

LG
LG AH-W096A0 Manuel utilisateur

LG
LG AMNW09GAF11 Manuel utilisateur

LG
LG LP1200DXR Mode d’emploi

LG
LG ARWB80LA2 Manuel utilisateur

LG
LG LW2511ER Manuel utilisateur