1. Heating Indicator lamp
2. Ready to use Indicator lamp
3. Cold water inlet (blue)
4. Hot water outlet (red)
5. Safety valve
6. Outer Body
7. Reset
PARTS LIST :
PRODUCT DIMENSIONS :
C
D
B
A
Model
1
3
A
195
225
B
295
335
C
60
60
D
150
195
in mm

TECHNICAL SPECIFICATIONS
50
Working pressure rating(psi)
Model No.
50
1 Litre
ABS ABS
3 Litres
Capacity(Litres) 1 3
Wattage (in KW) 3.0 3.0
Power Supply 230V, 50Hz, AC, Single phase
Minimum hot water
output temperature(degree C) 40 40
Outer body
Stainless steel
Water tank
Copper sheathed, Tubular with mineral filling
Heating Element
Thermostat Stem-type Preset at 55 degree Celsius
Thermal Cutout Stem-type, Reset type to operate at 90 degree celsius
Fusible Plug Operate at 98 degree Celsius
*Due to continuous improvements in product, specifications are subject to change without prior notice
A. Thermostat
This device "cut-off" and "cut-in" the power supply at desired
shown by the indicator provided. This shows the proper working of the thermostat.
B. Thermal Cutout
A non-self resetting thermal cutout is provided as a safety device. When the
manually reset with the button provided at bottom of the unit, before the water
C. Safety Valve
This valve prevents the built-up of excessive pressure within the water heater by
SAFETY DEVICES
Water heater is built-in with a host of Safety Devices to ensure your safety at all
times. The operation of these devices are described below.
temperature range,
This is pre-calibrated device.
thermostat fails to function, it cuts-off the power. The thermal cutout has to be
heater can start operating again.
releasing water from the drain.

Please read operating instructions before using the appliance to ensure safe and
Do's
1. Before plugging in the socket ensure that the mains voltage complies with the
rated one.
2. The gate valve at the inlet shall be kept open.
3. Make sure that no other appliance(s) is (are) plugged into the same circuit with
heater, as this may overload the circuit.
4. If the main cord of the heater is damaged, authorized service personnel must
only replace it.
.Don'ts
1. Do not switch ON the heater till it is completely filled with water.
CUT OFF NEON
HEATING NEON
L
N
E
TC TS HE
D. Fusible Plug
This is an alloy which works when all the above three safety devices fail to work.
It melts & release the pressure of water from the tank.
IMPORTANT INSTRUCTION
reliable performance.
2. Do not install non return valve at the inlet.

3. Safety devices are pre-set and sensitive. Do not tamper with them. This could
4. Do not use outdoors. This product is for household use only.
5. In case of any abnormality during operation, immediately switch OFF the main
service center.
1. Installation shall be done by a qualified plumber/electrician.
2. There should be enough space around the heater for easy installation and
3. Make sure that the supporting walls or fixtures are strong enough to carry the
filled with water.
4. There should be a minimum space of 50 cm between the heater unit and roof.
5. Drill hole in wall, fix the wall plate with the bolts & washers, till the wall plate
heater with water safely.
6. After fixing the wall plate tug down the water heater and ensure that both
Read operating instructions before using the water heater to ensure safe and
A. Using the heater for the first time :
1. Do not switch "ON" before filling the heater with water.
2. Leave the hot water tap open. Now fill the heater by opening the control
3. When the heater is full, water will start flowing through the hot water tap.
HOW TO INSTALL
OPERATION OF WATER HEATER
be hazardous.
power supply and contact the nearest
servicing.
weight of the heater when it is completely
This is to ensure that heater can be removed easily when required.
is firm enough to carry the weight of water
fingers of bracket are properly seated in the mounting slot.
reliable performance.
valve at the inlet.
Close the hot water tap.

4. Now the heater will always have water inside. Water drawn will be replaced
municipal main supply.
5. Always keep the inlet control valve open.
6. Now switch "ON" the power supply to the heater.
B. Using the heater regularly :
1. Always keep the inlet valve open so that water drawn from the hot water tap
2. thermostat will cut-off
3. The thermostat is pre-calibrated at 55°C.
4. As the temperature of water inside the tank drops thermostat again switches
5. By controlling flow of water, desired hot water can be achieved.
Greater the
vice-versa.
Routine Inspection/Maintenance Chart
S.No. Inspection item Frequency Remarks
1. Heating element Every 3 months/ In case of bad water
of use remove scale from
heating Element
2. Built in Pressure Every 2 months In case of hard
Release Valve of use water clear salts
deposited on the Hole
and Spring
3. Fusible plug Every 3 months In case of hot water
of use remove scale
by water from the over head tank or from
is automatically replaced from the main supply.
When the water reaches the required temperature the
the power supply automatically.
the power supply on.
flow, lower will be the temperature of water and
CLEANING AND MAINTENANCE

1.
Under the terms of warranty, if Service engineer visits, the customer has to bear
actual to and fro traveling and incidental expenses as prevailing from time to time.

WARRANTY CARD
Model No. ........................................................... Serial No. .........................................
Invoice No. ........................................................... Date of Sale .....................................
Owner’s Name and Address ..........................................................................................
........................................................................................................................................
........................................................................................................................................
Tested by .................................................. Remarks ......................................................
Authorised Dealer/ Franchisee
Note : Suggestions are welcome. The ones implemented, shall be rewarded.
You can directly write to the Vice President of the company at vp@kunstocom.com
CUSTOMER CARE
TOLL FREE: 1800 - 103 - 2070
Email: customercare@kunstocom.com
Website: www.kunstocom.com
Kunstocom (India) Ltd.
An AKC Group Company
Factory/Office : C-47, Phase -2, Noida - 201305 (India)
Phone: 0120 - 476 3800
Table des matières
Autres manuels Kunstocom Chauffe-eau
Manuels Chauffe-eau populaires d'autres marques

Kenmore
Kenmore 153.582400 Manuel utilisateur

Applimo
Applimo Edel AIR Manuel utilisateur

STIEBEL ELTRON
STIEBEL ELTRON Eltronom SHU 5 S Manuel utilisateur

clage
clage E-Mini Series Manuel utilisateur

Toyotomi
Toyotomi Oil Miser OM-180 Manuel utilisateur

Bradford White
Bradford White EF Series Manuel utilisateur