KomelCo DT602 Manuel utilisateur

2 -Wire Intercom System
DT602 Series User Manual
DT-ENG-602/602D-V1 20140721
DT602 DT602D

CONTENTS
1.Parts and Functions............................................................................................. 1
2.Terminal Descriptions .......................................................................................... 1
3.Specications ...................................................................................................... 2
4.Mounting.............................................................................................................. 2
4.1 Mounting Without Rainy Cover...................................................................... 2
4.2 Mounting With Rainy Cover........................................................................... 3
4.3 Placing Name Label ...................................................................................... 3
5.System Wiring and Connections ......................................................................... 4
5.1 Basic Connection........................................................................................... 4
5.2 Electric Lock Connection............................................................................... 4
5.2.1 Door Lock Controlled with Internal Power ............................................. 4
5.2.2 Door Lock Controlled with Dry Contact ................................................. 5
5.2.3 Unlock parameter setting(set on monitor) ............................................. 5
5.3 Multi Doorstations Connection....................................................................... 6
5.4 Multi Monitors Connection............................................................................. 7
5.4.1 Basic IN-OUT Wiring Mode ................................................................. 7
5.4.2 With DBC4A Wiring Mode ................................................................... 8
6.Setup ................................................................................................................... 9
6.1 ID Settings of Doorstation ......................................................................... 9
6.2 Unlock Delay Time Setting ........................................................................ 10
6.3 Ringback Tone Setting ............................................................................... 11
7.Cables Requirements.......................................................................................... 12

-1-
1.Parts and Functions
Camera Lens
Speaker
Nameplate
Call Button
Microphone
Night Light
Rainy Cover
23 mm
90 mm
145 mm
2.Terminal Descriptions
1 2 3
JP/LK
PL
S+ S-
Main Connect Port
BUS

-2-
•JP/LK: Lock control jumper, to select the lock type(see 5.2.1 , 5.2.2).
•Main Connect Port: To connect the bus line and the electronic locks.
•BUS: Connect to the bus line, no polarity.
•PL: External lock power input, connect to the power positive(power +).
•S+: Lock power(+) output.
•S-: Lock power(-) output, connect to the power(-) input of locks(only when using the camera to
power the locks, if using the external power supply for the locks, the S- will not be connected).
3.Specications
•Power Supply : DC 24V;
•Lock Power supply: 12Vdc, 300mA(Internal Power);
•Power Consumtion: Standby 33mA; Working status 110mA;
•Camera: Color ARS; 500 TV Lines;
•Unlocking time: 1~30s(Default 1s);
•Working temperature: -15ºC ~ 55ºC;
•Dimension: 145(H)×90(W)×23(D)mm(Without rainy cover).
4.Mounting
4.1 Mounting Without Rainy Cover
The host kit is
installed on the wall.
Connect the cable correctly.
1 2
54
3
6
Placing name label.
The surface shell kits are
installed on the host kit. Use the screw to fix the host. Installation is complete.

-3-
4.2 Mounting With Rainy Cover
The rainy cover and main
unit are installed on the wall.
Connect the cable correctly.
1 2
43 5
The surface shell kits are
installed on the host kit. Use the screw to fix the host. Installation is complete.
Rainy cover
The distance between the
top of main unit and rain
cover should be not less
than 3mm.
Main unit
Rainy cover
Main unit
≥3mm
4.3 Placing Name Label
Move the plastic cover away to open the transparent name label cover, insert a name paper, then put
the plastic cover back to the panel.
STEP 1
Unscrew the screws.
STEP 2
Replace name label.

-4-
5.1 Basic Connection
5.System Wiring and Connections
BUS(IM) BUS(DS)
PC6
AC~
-
+
L1 L2 PL S+ S-
Doorbell Button
Switch
1 2 3
ON
DIPS
5.2 Electric Lock Connection
5.2.1 Door Lock Controlled with Internal Power
Note:
1. Electronic lock of Power-on-to-unlock
type should be used.
2. The door lock is limited to 12V, and
holding current must be less than 250mA.
3. The door lock control is not timed from
Exit Button(EB).
4. The Unlock Mode Parameter of Monitor
must be set to 0 (by default).
5. When it connect Electronic lock, the
jumper position in 2-3.
6. When it connect E-magnetic lock, the
jumper position in 1-2.
EB
*
LOCK
PL S+S-
connect Electronic lock, the jumper position in 2-3.
1 2 3
BUS
connect E-magnetic lock, the jumper position in 1-2.
1 2 3

-5-
5.2.2 Door Lock Controlled with Dry Contact
Note:
1. The external power supply must be
used according to the lock.
2. The jumper must be taken off
before connecting.
3. Setup the Unlock Mode of Monitor
for different lock types.
•Power-on-to-unlock type:Unlock
Mode=0 (by default)
•Power-off-to-unlock type:Unlock
Mode=1
LOCK
Take off the Jumper
POWER
SUPPLY
BUS PL S+S-
5.2.3 Unlock parameter setting(set on monitor)
Note:
1.must connect DT602/602D correctly before setting.
2.the parameter will be saved in DT602/602D automatically,so you need only set on one monitor.
3.Here we take DT47M(the monitor) for example, please refer to the corresponding user manual.
1.Touch icon on
main menu page.
2.Touch UNLOCK
button and hold for 2s.
3.A digital keypad will
be shown.
About
Local Address 00.00
Video Standard AUTO
System Verson 00.01.00
Display Driver 1.0
Front 1.0
UI 1.0
INSTALLER SETUP 123
_

-6-
5.3 Multi Doorstations Connection
L1 L2 PL S+ S- L1 L2 PL S+ S- L1 L2 PL S+ S- L1 L2 PL S+ S-
1# Camera2# Camera3# Camera4# Camera
(Device Address:3) (Device Address:2) (Device Address:1) (Device Address:0)
100~240VAC
DBC4A
A B C D
OFF
ON
Impedance
switch
BUS(IM) BUS(DS)
PC6
AC~

-7-
5.4.1 Basic IN-OUT Wiring Mode
5.4 Multi Monitors Connection
Code=31
(Device Address:0)
BUS(IM) BUS(DS)
PC6
AC~
100~240VAC
NOTE:Here we take DT47M(the monitor) for example.
Code=30
Code=0

-8-
5.4.2 With DBC4A Wiring Mode
(Device Address:0)
Code=0
OFF ON
OFF ON
DBC4A
A B C D
DBC4A
A B C D
Impedance
switch
Impedance
switch
NOTE:Here we take DT47M(the monitor) for example.
100~240VAC
BUS(IM) BUS(DS)
PC6
AC~
Code=2
Code=1
Code=3
Code=28
Code=30
Code=29
Code=31
Ce manuel convient aux modèles suivants
1
Table des matières