KMS UEGO CAN Fiche technique

kms.vankronenburg.nl
UEGO CAN controller
• Manual for installation and setup
• Handleiding voor installatie en setup
• Anleitung für Installation und Setup
EN—NL—DE


UEGO CAN controller
Part nr: 01-01-01-0010
Technical specifications and installa-
tion manual
kms.vankronenburg.nl
EN—NL—DE
EN

__________________________________________________________
KMS UEGO CAN controller
Part nr: 01-01-01-0010 4
kms.vankronenburg.nl
EN—NL—DE
EN
This document contains detailed information about the KMS UEGO CAN
controller. Additional information, user manuals, wiring examples ands
software can be found on our website: kms.vankronenburg.nl or on the
software CD included with the ECU.
1. Package contents
• UEGO CAN controller (84mm long x 35mm width x 24mm height incl.
connector
• UEGO CAN controller wiring loom (with connectors attached)
• CAN extension hub 2m
• Adapter (for easy ground fitting)
• Welding bung (stainless steel, M18x1,5)
• Instruction manual
• Wide-band lambda sensor (LSU 4.9)
• Contra connector (to attach the 3-pole connector)
UEGO CAN controller wiring loom CAN extension hub (2 metres)

__________________________________________________________
KMS UEGO CAN controller
Part nr: 01-01-01-0010 5
kms.vankronenburg.nl
EN—NL—DE
EN
2. Installation of the KMS UEGO CAN controller
The KMS UEGO CAN controller is splash waterproof. However, it is best to
place it in a dry place where temperatures don’t exceed 65 °C.
Warning: do not place the UEGO CAN controller and it’s wires nearby any
‘high powered’ cables such as sparkplug leads, as it can cause electrical
interference resulting in malfunction.
Included with the KMS UEGO CAN controller is a wiring loom which consists
Lambda connector ECU connection CAN-bus
Main connector Ground connector

__________________________________________________________
KMS UEGO CAN controller
Part nr: 01-01-01-0010 6
kms.vankronenburg.nl
EN—NL—DE
EN
2.1. Main 12-pole connector
Connect to UEGO CAN controller. Pin functions are as following:
2.2. Single pole connector for heater ground
Connect to chassis ground.
2.3. 3-pole (superseal) connector for power supply and signal
This supplies power and ground to the CAN controller as well as signal output from
controller to ECU. Connect as following:
Pin Nr. KMS Colour Function Details
1 Red 12V supply
2 Green Can Low (-)
3 Black Heater ground
4 Blue Ipr Sensor calibration
5 White H- Sensor heater ground
6 Red Ip Sensor Signal
7 Black Ground
8 White Can High (+)
9 White Sensor signal Analog signal output (type C)
10 Black Un Sensor reference voltage supply
11 Grey H+ Sensor heater voltage supply
12 Yellow Vm Sensor reference ground
Connector Wire Function MD35 pin nr MP25 pin nr
Pin 1 Red + 12V 35: 12V Aux sup- 13: 12V Lambda sup-
Pin 2 White Signal out 31: Lambda
signal 1
32: Lambda sig-
nal 2
1: Lambda signal
4: Analog aux input
Pin 3 Black Ground 23: ECU ground 25: ECU ground

__________________________________________________________
KMS UEGO CAN controller
Part nr: 01-01-01-0010 7
kms.vankronenburg.nl
EN—NL—DE
EN
2.4. 6-pole connector for lambda sensor
Connect to wide-band lambda sensor.
2.5. 4-pole CAN connector
For connection to CAN display, ECU CAN input, etc. Pin functions are as
following:
Male CAN connector front: Female CAN connector front:
The CAN connection hub included in the package can be used to connect
the KMS UEGO CAN controller to the CAN bus. For every CAN device that’s
connected to the CAN bus, a CAN connection hub will be needed.
Pin nr Colour Function
1Red 12V supply
2Black Ground
3White Can High (+)
4Green Can Low (-)

__________________________________________________________
KMS UEGO CAN controller
Part nr: 01-01-01-0010 8
kms.vankronenburg.nl
EN—NL—DE
EN
3. Wiring of the CAN bus
The KMS UEGO CAN controller can communicate via CAN communication through
the CAN bus (grey wire) which consists of two pair of twisted wires (green and
white, red and black). Up to 10 CAN devices may be connected to the CAN bus.
These devices must be placed within 0,5m of the CAN bus.
If the CAN Bus is connected to the KMS MP25, MA25(M), IA23 or FA23 ECU (using the
serial to CAN converter) or the KMS MD35 ECU, it is not necessary to use a CAN ter-
minating resistor plug. The KMS MD35 ECU and serial to CAN converter already have
a terminating resistor. When using the UEGO CAN controller separately on a
standalone CAN bus (for example in combination with a KMS CAN display), it is nec-
essary to use a CAN terminating resistor plug on one end of the CAN bus. Below, a
drawing is shown of the correct CAN Bus wiring, including a KMS ECU. The following
page contains a drawing showing the correct wiring of the CAN bus excluding a KMS
ECU.

__________________________________________________________
KMS UEGO CAN controller
Part nr: 01-01-01-0010 9
kms.vankronenburg.nl
EN—NL—DE
EN
4. Lambda sensor specifications
The lambda sensor used for the KMS UEGO CAN controller is a 6 wire LSU4.9 wide-
band Lambda sensor. This sensor has the following specifications:
• Thread: M18x1,5
• Spanner size: 22 Hexagon
• Maximum continuous operating temperature: 930 °C
• Maximum temperature: 1030 °C (maximum 10 minutes)
• Mounting torque: 60 Nm max
• Sensor warm-up will take about 20 seconds. Accurate measure-
ment is possible when exhaust gas temperature is at working
temperature.
• Sensor lifetimes differ for every application, but will dramatically
decrease by the following factors:
• Leaded fuel
• Contaminants such as silicon, lead, oil, etc. (use sensor
-friendly sealants)
• Exposure to exhaust fumes without any heating control active
• Incorrect placement in the exhaust that can overheat
the sensor (for correct placement see page 5)

__________________________________________________________
KMS UEGO CAN controller
Part nr: 01-01-01-0010 10
kms.vankronenburg.nl
EN—NL—DE
EN
Warning: The Lambda sensors are factory calibrated with a trim-
ming resistor placed in the sensor connector, so the connector must
not be cut off.
5. Installation of the lambda sensor
The Lambda sensor should be fitted to the exhaust system with the sensor
tip in the exhaust gas flow. When fitting the Lambda sensor, the following
factors need to be taken into account:
• Place the sensor at least 1 meter fron the open end of the exhaust
system to avoid incorrect readings due to air from the outside.
• If possible, do not place the sensor near exhaust slip joints. It is pos-
sible for some applications to allow air to enter resulting in incorrect
readings.
• Installation angle should be inclined at least 10° towards horizontal
(electrical connection upwards). Thus preventing the collection of
liquids between sensor housing and sensor element during the cold
start phase. See figure below.
Autres manuels pour UEGO CAN
1
Table des matières
Langues :
Autres manuels KMS Contrôleurs