Keystone KSTAD50B Manuel utilisateur

Before operating this product, please read the
instructions carefully and save this manual for
future use.
DEHUMIDIFIER
Model: KSTAD50B
KSTAD70B


Producto

1 866 646 4332
1 866 646 4332
MIDEA AMERICA CORPORATION
PRODUCT REGISTRATION CENTER
11800 NW 100 ROAD STE 4
MEDLEY FL 33178-1037

SOCIABLE REMARK
DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection
of such waste separately for special treatment is necessary.
It is prohibited to dispose of this appliance in domestic household waste.
For disposal, there are several possibilities:
A) The municipality has established collection systems, where electronic waste can
be disposed of at least free of charge to the user.
B) When buying a new product, the retailer will take back the old product at least
free of charge.
C) The manufacture will take back the old appliance for disposal at least free of
charge to the user.
D) As old products contain valuable resources, they can be sold to scrap metal
dealers.
Wild disposal of waste in forests and landscapes endangers your health when
hazardous substances leak into the ground-water and find their way into the food
chain.
When using this dehumidifier in the European countries, the following information
must be followed:

11
CONTENTS
SAFETY PRECAUTIONS
Warning ..........................................................................................................................................2
Caution ...........................................................................................................................................2
Electrical information ......................................................................................................................3
OPERATING THE UNIT
When using the unit .......................................................................................................................7
Removing the collected water ........................................................................................................8
CARE AND MAINTENANCE
Care and cleaning of the dehumidifier ...........................................................................................9
TROUBLESHOOTING TIPS
Troubleshooting tips .....................................................................................................................10
CONTROL PADS ON THE DEHUMIDIFIER
Control pads....................................................................................................................................4
Other features................................................................................................................. ...............5
IDENTIFICATION OF PARTS
Identification of parts ......................................................................................................................6
Positioning the unit .........................................................................................................................7

22
SAFETY PRECAUTIONS
Do not exceed the rating
of the power outlet or
connection device.
Do not modify power cord
length or share the outlet
with other appliances
Disconnect the power if
strange sounds, smell, or
smoke comes from it.
Otherwise, it may cause electric
shock or fire due to excess heat
generation.
It may cause electric shock or
fire due to heat generation.
It may cause fire and electric
shock.
It may cause electric shock or fire
due to heat generation.
It may cause electric shock.
It may cause failure of machine
or electric shock.
It contains contaminants and
could make you sick.
It may cause electric shock or fire.
Plastic parts may melt and cause
a fire.
It may cause electrical shock or
injury.
It may cause an explosion or fire.
Do not operate or stop the
unit by switching on or off
the power.
Do not insert or pull out
plug with wet hands.
You should never try to take
apart or repair the unit by
yourself.
Do not drink or use the
water drained from the unit.
Do not damage or use an
unspecified power cord.
Do not place the unit near
a heat source.
Before cleaning, turn off
the power and unplug the
unit.
Do not use the machine near
flammable gas or combustibles, such
as gasoline, benzene, thinner, etc.
!!!!
CAUTION
Do not use the unit in small
spaces.
Lack of ventilation can cause
overheating and fire.
Do not put in places where
water may splash onto the
unit.
Water may enter the unit and
degrade the insulation. It may
cause an electric shock or fire.
Place the unit on a
level, sturdy section
of the floor.
If the unit falls over, it may
cause water to spill and
damage belongings, or
cause electrical shock or
fire.
!!
To prevent injury to the user or other people and property damage, the following instructions must be
followed. Incorrect operation due to ignoring of instructions may cause harm or damage.
The seriousness is classified by the following indications.
This symbol indicates the possibility of death or serious injury.
Meanings of symbols used in this manual are as shown below.
Always do this.
Never do this.
CAUTION
This symbol indicates the possibility of injury or damage to property.
WARNING
WARNING
It may cause bucket full protect of
the unit and cause electric shock.
Do not take the water buc-
ket out during operation.

33
SAFETY PRECAUTIONS
Do not cover the intake or
exhaust openings with
cloths or towels.
A lack of air flow can lead
to overheating and fire.
Never insert your finger or
other foreign objects into grills
or openings. Take special care
to warn children of these
dangers.
Do not use in areas
where chemicals are
handled.
This will cause the unit
deterioration due to
chemicals and solvents
dissolved in the air.
Care should be taken when
using the unit in a room with
the following persons:
Infants, children, elderly people,
and people not senstive to
humidity.
You may be injured if you
fall or if the unit falls over.
Water may spill inside the
unit, causing insulation
failure and electrical
shock or fire.
!!
!!
It may cause failure of
appliance or accident.
There is danger of fire or
electric shock.
Do not place heavy object on the
power cord and take care so that
the cord is not compressed.
Operation without filters
may cause failure.
Always insert the filters
securely. Clean filter
once every two weeks.
CAUTION
Do not climb up on
or sit on the unit.
If water enters the unit, turn
the unit off and disconnect the
power , contact a qualified
service technician.
!!
Do not place flower
vases or other water
container on top of
the unit.
The manufactures nameplate is located on the rear panel of the unit and contains electrical and other
technical data specific to this unit.
Be sure the unit is properly grounded. To minimize shock and fire hazards, proper grounding is important.
The power cord is equipped with a three-prong grounding plug for protection against shock
hazards.
Your unit must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is
not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician
install the proper receptacle.
Ensure the receptacle is accessible after the unit installation.
Do not use extension cords or an adapter plugs with this unit. However, if it is necessary to use an
extension cord, use an approved Dehumidifier extension cord only (available at most local hardware
stores).
To avoid the possibility of personal injury, always disconnect the power supply to the unit, before installing
and/or servicing.
Electrical Information
It may cause electric shock
or failure of appliance.

44
CONTROL PADS ON THE DEHUMIDIFIER
Control pads
33
When you pushthe button tochange
operation modes, theunit will make
a beep soundto indicate thatit is
changing modes.
NOTE: The control panelof the unityou purchased maybe slightly differentaccording to the
models.
Fig.1
Fan Pad
Control the fan speed. Press to select either High
or Normal fan speed. Set the fan control to High for
maximum moisture removal. When the humidity has
been reduced and quiet operation is preferred, set
the fan control to Normal.
22
Filter Pad
The check filter feature is a reminder to clean the
Air Filter for more efficient operation. The Filter
light(Clean filter l ight) will illuminate after 250 hours
of operation. To reset after cleaning the filter, press
the Filter pad and the light will go off.
55
Humidity Set Control Pads
77: Up/Down Pads
TIMER Set Control Pads
Use the Up/Down pads to set the Auto
start and Auto stop time from 0.0 to 24.
The humidity level can be set within a range of
35%RH(Relative Humidity) to 85%RH(Relative
Humidity) in 5% increments.
For drier air, press the pad and set to a lower
percent value(%).
For damper air, press the pad and set a higher
percent value(%).
66
Timer Pad
Press to initiate the Auto start and Auto stop feature,
in conjuction with the and key pads.
33
High fan
indicator light
Filter
Full
Cont. On Off
Turbo
Normal
Auto defrost
11
22
44
55
6677
Clean filter
indicator light
Continuous
operation on
indicator light Timer on/off
indicator light
44
Power Pad
Press to turn the dehumidifier on and off.
Bucket full
indicator light
Auto defrost operation on
indicator light
Low fan
indicator light
Cont.Cont.
11
Continue Pad
Press to activate the continuous dehumidifying
operation.

55
CONTROL PADS ON THE DEHUMIDIFIER
Other features
Bucket Full Light
Glows when the bucket is ready to be
emptied, or when the bucket is removed
or not replaced in the proper position.
When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue
to run until the frost disappears.
Auto Defrost
Wait 3 minutes before resuming operation
After the unit has stopped, it can not be restart
opertation in the first 3 minutes. This is to protect
the unit. Operation will automatically start after
3 minutes.
Setting the Timer
When the unit is on, first press the Timer
button, the Timer Off indicator light
illuminates. It indicates the Auto Stop
program is initiated. Press it again the
Time On indecator light illuminates.It
indicates the Auto Start is initiated.
Press or hold the UP or DOWN pad to
change the Auto time by 0.5 hour incre-
ments, up to 10 hours, then at 1 hour
increments up to 24 hours. The control
will count down the time remaining until
start.
The selected time will register in 5 seconds
and the system will automatically revert
back to display the previous humidity
setting.
When the Auto start & Auto stop times are
set, within the same program sequence,
TIMER ON OFF indicator lights illuminate
identifying both ON and OFF times are
now programmed.
Turning the unit ON or OFF at any time or
adjusting the timer setting to 0.0 will cancel
the Auto Start/Stop function.
When LED display window displays the
code of P2, the Auto Start/Stop function
will also be cancelled.
When the unit is off, first press the Timer
button, the TIMER ON indicator light
illuminates. It indicates the Auto Start
program is initiated. Press it again the
Time Off indecator light illuminates.It
indicates the Auto Stop is initiated.
Check filter feature
The system starts to count the time once the fan
motor operates. The check filter feature can be
only activated when the accumulated operation
time achieves 250 hours or more. The Reset
light(Clean filter indicator light) flashes at one time
per second, after finishing clean the air filter, press
the Filter pad and the Reset light(Clean filter indicator
light) goes off.
1010
Display
Shows the set % humidity level from 35% to 85% or auto
start/stop time (0~24) while setting, then shows the actual
( 5% accuracy) room % humidity level in a range of 30%
RH(Relative Humidity) to 90%RH(Relative Humidity).
Error Codes and Protection Code:
AS- Humidity sensor error--Unplug the unit and plug it back
in. If error repeats, call for service.
ES- Temperature sensor error-- Unplug the unit and plug it
back in. If error repeats, call for service.
P2- Bucket is full or bucket is not in right position-- Empty
the bucket and replace it in the right position.
E1- Unit malfunction-- Unplug the unit and plug it back in.
If error repeats, call for service.
Auto Shut Off
The dehumidifier shuts off after 30 seconds when
the bucket is full, or when the bucket is removed
or not replaced in the proper position.When the
setting humidity is reached, the unit will be shut
off automatically. For some models,the fan motor
will continue operating.
Auto-Restart
If the unit breaks off unexpectedly due to the power cut,
it will restart with the previous function setting automa-
tically when the power resumes.
EC- Unit malfuction--
for
Please make sure whether the
enviroment temperature is suitable for the stated
temperature in the manual or not.If not,please operate
the unit under the stated temperature.If the enviroment
temperature is suitable for the stated temperature,please
call service.
Ce manuel convient aux modèles suivants
1
Table des matières
Langues :
Autres manuels Keystone Déshumidificateur

Keystone
Keystone KSTAD706PB Manuel utilisateur

Keystone
Keystone KSTAD70B Manuel utilisateur

Keystone
Keystone DD7L Junior Manuel utilisateur

Keystone
Keystone KSTAD507A Manuel utilisateur

Keystone
Keystone CD030IU-DP Manuel utilisateur

Keystone
Keystone R-KSTAD50B Manuel utilisateur

Keystone
Keystone KSTAD30B Manuel utilisateur

Keystone
Keystone KSTAD224D Manuel utilisateur

Keystone
Keystone KSTAD110PD Manuel utilisateur

Keystone
Keystone KSTAD354D Manuel utilisateur