Kaden KD Series Manuel utilisateur

Kaden Wired Controller Manual | 1
Wired
Controller
Manual
DUCTED AIR CONDITIONER
KD24 | KD36 | KD42 | KD48 | KD60
KD Series

2| Kaden Wired Controller Manual
1. Safety Precautions 3
2. Installation Accessories 4
3. Installation Method 5
4. Specification 8
5. Features and Functions 9
6. Display Screen 10
7. Buttons 11
8. Operation 12
9. Timer Functions 14
10. Weekly Timer 15
11. Fault Alarms 18
Important note:
Read this manual carefully before installing
or operating your new air conditioning unit.
This manual gives detailed description of the
precautions that should be followed during operation.
Make sure to save this manual for future reference.
Table of Contents

Kaden Wired Controller Manual | 3
Read Safety Precautions Before Installation
Read the safety precautions carefully before installing the unit. Stated below are important safety issues that must
be obeyed:
1. Safety Precautions
Means improper handling may lead to personal death or severe injury.
Means improper handling may lead to personal injury or property loss.
WARNING
• Please ensure a professional installs the unit.
• Installation by other persons may lead to incorrect installation, electric shock or fire. Adhere to this installation manual.
CAUTION
• Do not install the unit in a place vulnerable to leakage of flammable gases. Leaking flammable gases around the
controller can result in fire.
• Do not operate with wet hands or let water enter the wired controller. Otherwise, electric shock may occur.
• The wiring should adapt to the wired controller current. Otherwise, electric leakage or over heating may occur and
result in fire.
• The specified cables shall be used in the wiring. No external force should be applied to the terminal.
This may result in damaged wiring and/or overheating which can create a fire hazard.

4| Kaden Wired Controller Manual
2. Installation Accessories
Select the installation location
Don’t install in areas that contain oil, vapor or sulfureted gas, otherwise, this product can deform which could permanently damage
the product.
1. Please confirm that you have all the following parts.
No. Name Qty. Remarks
1 Wired controller 1
2Wired controller manual 1
Kaden Wired Controller Manual | 1
Wired
Controller
Manual
DUCTED AIR CONDITIONER
KD24 | KD36 | KD42 | KD48 | KD60
KD Series
3 Screws 3 M4X20 (for mounting on the wall)
4Wall plugs 3 For mounting on the wall
5 Screws 2 M4X25 (for mounting on switch box)
6Plastic screw bars 2 For fixing on switch box
7 The connective wires group-1 1 Optional
8 The connective wires group-2 1 Connect to mainboard
9 Battery 1
2. Prepare the following assemblies on the site.
No. Name Qty. (embedded into wall)
1 Switch box 1
2Wiring tube (insulating sleeve and tightening screw) 1
Preparation before installation
1. This manual explains the installation requirements for the wired controller. Please refer to the wiring diagram of this installation
manual to wire the wired controller to the indoor unit.
2. The wired controller operates in a low voltage loop circuit. Do not directly contact the cable of 220V commercial electricity or
of 380V high voltage, and don’t wire this kind of wire in the loop; wiring clearance between configured tubes should be at the
range of 300~500 or above.
3. The shielded wire of the wired controller must be grounded reliably.
4. Upon completing the wired controller connection, do not use a mega to detect the insulation.
5. The connective cable of the wired controller should not be longer than 20 meters.
Precautions

Kaden Wired Controller Manual | 5
3. Installation Method
120
122
18.5
83.5
46
62
1. Wired controller size
2. Wiring principle sketch
red
black
yellow
brown
red
black
yellow
brown
Insert of the
mainboard CN40
Wired controller Indoor unit mainboard
4-Core Shield Cable,
the length is dictated by installation
-----------------------------------
-----------------------------------
-----------------------------------
-----------------------------------
3. Wiring figure
Mainboard
4-core shielding wire
The connective wires group-1
The connective wires group-2
CN40
• Connect the female joint of wires group from the mainboard with the male joint of connective wires group.
• Please connect the other side of connective wires group with the male joint of wires group leads from the wired controller.

6| Kaden Wired Controller Manual
4. Remove the upper part
of the wired controller
Insert a slotted screwdriver into the slots in the lower part of the
wired controller (2 places), and remove the upper part of the
wired controller.
NOTICE
The PCB is mounted in the upper part of the wired
controller. Be careful not to damage the board with
the slotted screwdriver.
Slots
5. Fasten the back plate of the wired controller
For exposed mounting, fasten the back plate on the
wall with the 3 screws (M4×20) and plugs.
For flush-mounting, fasten the back plate on the switch
box with 2 screws (M4×25) and fasten it on the wall with
1 screw (M4×20).
NOTICE
Put on a flat surface. Be careful not to distort the back plate of the wired controller by overtightening the mounting screws.
Back plate
Screws (M4×20)
Switch box
Back plate
Screw (M4×20)
Screws (M4×25)
6. Battery installation
• Put the battery into the installation site and make sure the
positive side of the battery is in accordance with the positive
side of installation site. (See figure opposite.)
• Please set the time during first operation. Batteries in the
wired controller can fail during a power failure. When power
is restored, if the time displayed is not correct, it means the
battery is dead and requires replacing.

Kaden Wired Controller Manual | 7
7. Wiring
A. In regards to wiring outlets,
there are four options.
Three need cutting.
CAUTION
• Avoid water ingress into the wired controller, use trap
and putty to seal the connectors of wires during wiring
installation.
• During installation, leave some length of the connecting
wires for convenient maintenance, when the controller
needs to be removed from its location.
Top side
wire outlet
Left side
wire outlet
Right side
wire outlet
Bottom side
wire outlet
Line groove
Line groove
Line groove
Line groove
Cutting place
of top side
wire outlet
Cutting place
of left side
wire outlet
Cutting place
of right side
wire outlet
B. Shielded wiring
diameter of wall hole
:
Φ20mm
Embedded switch
box wiring
Wiring
hole
Wiring through the wall
Wall hole and wiring hole
Putty
Putty
Putty
Trap
Trap
Trap

8| Kaden Wired Controller Manual
8. Reattach the upper part of the
wired controller
After adjusting the upper case click it into place; avoid clamping
the wiring during this process.
Note
All the pictures in this manual are for explanation
purpose only.
Your wired controller may be slightly different.
In this case the actual shape shall prevail.
4. Specification
Input voltage Ambient temperature Ambient humidity
DC 5V/DC 12V -5~43ºC RH40%~RH90%

Kaden Wired Controller Manual | 9
5. Features and Functions
POWER
MODE FAN SPEED
TIMER SWING SWING FOLLOW ME
DELAY/DAY OFF CONFIRM BACK COPY
Features
• Mode: Auto – Cool – Dry – Heat – Fan
• Fan speed: Auto/Low/Med/High
• Timer ON/OFF
• Temp setting
• Weekly timer
• Follow me
• Child lock
• LCD display
• Clock
• Infrared remote receiver (on some models)
Function
• LCD display.
• Malfunction code display: Displays error codes.
• 4-way wire layout design, no raised part at back, more
convenient to place the wires and install the device.
• Room temperature display.
• Weekly Timer.

10 | Kaden Wired Controller Manual
6. Display Screen
1 2 3 4 5
6
7
8
9
10
12 11
1. Operation mode
2. Fan speed
3. Faceplate function
4. Follow me function
5. Turbo mode
6. ºC / ºF
7. Temperature display
8. Lock
9. Room temperature
10. Clock display
11. On/Off timer
12. Timer display