PAGE
2.2. 11 Erase and Save all messages
-Press the “ ERASE ” key for about 2 seconds, all the messages will be erased after
hearing a long beep if the messages exits, or an alarm two-beep if no message exists.
-Press the “ ERASE ” key for about 2 seconds after all messages are been erased; the
erased messages will be saved after hearing a long beep. If any recording action is
conducted after all messages have been erased, no message can be saved.
2.2. 12 Answer-Record Mode
-Press “ ON/OFF ” key will toggle the “ DAM ON ” or “ DAM OFF ”.
-The PLAY/STOPLED will blink if new messages exist.
-The 2-digit LED displays the total number of saved messages.
2.2.13Answer-Only Mode
-When the total number of saved messages exceed 59 or the memory full occurs during
recording, the answering machine will change to answer-only mode automatically.
2.2.14 Setup/Display the Security Code
The security code is initially preset to “000”. The code range is from 000 to 999.
Procedure of security code setup/display is as follows:
-Press “ON/OFF” key for about 2 seconds and release to display current security code.
-Press “OGM/FORWARD” or “MEMO/REPEAT” key to increment or decrement the
digit.
-Press “ON/OFF” key for correct digit and advance to the setup of next digit.
-If no key is pressed for 8 seconds, the setup procedure will be aborted.
-Press “PLAY/STOP” key to quit the security code setup.
2.2.15 Room Monitor
While in remote control mode, the user can monitor the room status by entering the
corresponding tone command. In room Monitor State, the user can monitor the status from
telephone line. The duration of room Monitor State is set to 15 seconds.
2.2.16 ICM Recording
When a call is received in answer-record mode, the machine will play OGM1, and then
performs ICM recording.
The procedure of ICM recording is as follows:
-Answer the call and then play OGM1. The caller can press “ * ” to skip OGM play.
-A long beep will be heard, and then the ICM recording starts.
-The ICM recording stops if any of the following events occurs, i.e., 8 seconds of
silence/continuous signal/5 seconds busy tone,or record time up to 1 minute, or parallel
phone picked up, or “ PLAY/STOP ” key pressed. If parallel phone picked up is
detected, the message being recorded will be saved as a new message. If press
“ PLAY/STOP ” key, the message being recordedwill not be saved.
-A long beep tone will be transmitted to indicate that ICM recording is finished.
-If memory full occurs during ICM recording, pre-recorded OGM2 “Memory full, please
call later” will be announced before the machine releases line.
2.2.17Rings Setup
-Rings detected to enable line interface will be 5 rings or Toll save 2/5 rings.