Junt Smart Control 8 Manuel de l'opérateur

Product documentation
Smart Control 8
Art. no.: SC 0081 U
ALBRECHT JUNG GMBH & CO. KG
Volmestraße 1
58579 Schalksmühle
GERMANY
Tel. +49 2355 806-0
Fax +49 2355 806-204
www.jung.de
08/2021

Page 2 of 16SC 0081 U
Table of contents
Table of contents
1 Safety instructions and device components .................................................3
1.1 Safety instructions....................................................................................................... 3
1.2 Device components ..................................................................................................... 3
2 Function ............................................................................................................3
2.1 Intended use................................................................................................................. 3
2.2 Product characteristics ............................................................................................... 4
2.3 Included in delivery ..................................................................................................... 4
3 Mounting and electrical connection ...............................................................4
3.1 Information for electrically skilled persons............................................................... 4
3.2 Mounting in installation box or appliance box.......................................................... 4
3.3 Mounting the adapter .................................................................................................. 5
3.4 Connection ................................................................................................................... 6
3.5 Mounting of Smart Control ......................................................................................... 7
4 Commissioning ................................................................................................7
4.1 Switching on................................................................................................................. 7
4.2 Settings – Overview of the menu structure............................................................... 7
4.3 Opening the settings ................................................................................................... 8
4.4 Selecting the language................................................................................................ 8
4.5 Selecting date and time............................................................................................... 8
4.6 Changing the system password................................................................................. 8
4.7 Updatingthermware ................................................................................................. 8
5 Operation ..........................................................................................................9
5.1 Operating elements ..................................................................................................... 9
5.2 Control elements........................................................................................................10
5.3 Device settings........................................................................................................... 11
5.4 Operation using apps in the main menu .................................................................12
5.5 Apps for building automation...................................................................................12
5.6 Create app link in the main menu.............................................................................13
5.7 App “System Update“ ...............................................................................................14
5.7.1 Restoring default settings ............................................................................................................14
5.7.2 Updatingthermwarewithoutinternetconnection......................................................................15
6 Cleaning ..........................................................................................................16
7 Technical data.................................................................................................16
8 Accessories ....................................................................................................16
9 Warranty ..........................................................................................................16

Page 3 of 16SC 0081 U
Safety instructions and device components
1 Safety instructions and device components
1.1 Safety instructions
Electrical devices may only be mounted and connected by electrically skilled persons.
Seriousinjuries,reorpropertydamagepossible.Pleasereadandfollowmanualfully.
Danger of electric shock. During installation and cable routing, comply with the regulations and
standards which apply for SELV circuits.
These instructions are an integral part of the product and must remain with the end customer.
1.2 Device components
Fig. 1: Device components
1 Installation box
2 Adapter
3 Smart Control
2 Function
2.1 Intended use
- Visualising and operating system statuses and information on building automation
- Mounting horizontally (recommended) or vertically
- Mountinginaush-mountedinstallationbox(ref.-no.EBG24orSC7EBG)oronapplianceboxaccording
to EN 60670-1 (recommendation: at a depth of approx. 60 mm)
123

Page 4 of 16SC 0081 U
Mounting and electrical connection
2.2 Product characteristics
- High-resolution HD display
- Proximity sensor
- Capacitive touch screen
- Cleaning mode with touch screen lock
- Fanless, without mechanical moving parts
- KNX visualisation in combination with Visu Pro Server
(ref.-no.: JVP-SERVER-H2, JVP-SENEC-H2)
- KNX visualisation in combination with Smart Visu Server
(ref.-no.: SV-SERVER)
- eNet visualisation in combination with eNet server for rail mounting
(ref.-no.: ENET-SERVER) from software version 2.2
- Door intercom function only in combination with Siedle Smart Gateway SG 650-.. or SG 150-..
- Display of up to six IP camera images
- Image memory integrated in Smart Gateway
2.3 Included in delivery
- Smart Control 8
- Smart Control Adapter for wall installation
- Operating instructions
3 Mounting and electrical connection
3.1 Information for electrically skilled persons
DANGER
Electrical shock on contact with live parts in the installation environment.
Electrical shocks can be fatal.
Before working on the device, disconnect the power and cover live parts in the area!
3.2 Mounting in installation box or appliance box
TheSmartControlisdesignedformountinginaush-mountedinstallationbox(ref.no.EBG24or
SC7EBG).TheSmartControladapterisscrewedontotheinstallationbox.
Installation boxes from other manufacturers must match the overall dimensions and holes of the adapter and
the Smart Control. (See technical data for overall dimensions)
Theinstallationboxmustbepreciselyalignedandmountedushinthewall.
Alternatively, an appliance box according to EN 60670-1 can be used for mounting the Smart Control. The
Smart Control adapter is not mounted directly on the appliance box, but on the wall.
The recommended depth of the appliance box is approx. 60 mm.

Page 5 of 16SC 0081 U
Mounting and electrical connection
3.3 Mounting the adapter
83
58
Fig. 2: Mounting the adapter
1 Adapter locking screw
2 Fixing hooks
• Mounttheadapterontheinstallationboxwithatotaloffourlockingscrews(1).(g.2)
When mounting on an appliance box, the adapter must be mounted on the wall. The adapter must be
placed in such a way that the appliance box is located in the indentation of the adapter. The appliance box
isthusnotlocatedverticallyinthecentreoftheadapter,butwithadownwardoset.
1
2
2
1
1
1
2
2

Page 6 of 16SC 0081 U
Mounting and electrical connection
3.4 Connection
Fig. 3: Connection
3 Power supply 5 LAN/Ethernet
4USB2.0typeA 6Mini-USBOTG
Requirements:
- Ethernet connection (LAN)
- Power supply via power supply adapter, ref. no.: NT 2415 REG VDC
• Connectthepowersupply(3)andLAN(5).(g.3)
4
6
3
5

Page 7 of 16SC 0081 U
Commissioning
3.5 Mounting of Smart Control
Fig. 4: Mounting of Smart Control
8 Openings for wall mounting
9 Smart Control locking screws
• Placetheopeningsforwallmounting(8)ontheSmartControlonthexinghooks(2)ontheadapter.
(g.2andg.4)
To do this, place the openings for wall mounting above the hooks and engage them downwards.
• FastentheSmartControltotheadapterontheundersidewithatotaloftwolockingscrews(9).(g.4)
4 Commissioning
4.1 Switching on
After connecting, the device is switched on automatically and the operating system is started.
After the start-up process, you must make the settings for commissioning.
4.2 Settings – Overview of the menu structure
- General
- Language
- Date/time
- Design
- Display
- Advanced
- System password
9
8
8
9
8
8

Page 8 of 16SC 0081 U
Commissioning
4.3 Opening the settings
• Select the JUNG logo in the main menu (JUNG Launcher).
Password entry opens.
• Enter the system password.
The default system password is “0000“.
The settings open.
4.4 Selecting the language
• Open the settings.
• Select the menu “General”.
• Select the submenu “Language”.
Available languages are displayed.
• Select the language.
The language is selected.
4.5 Selecting date and time
• Open the settings.
• Select the menu “General”.
• Select the submenu “Date/time”.
• Make the settings:
- autom. date/time: activated
- autom. time zone: deactivated
- select the time zone (e.g. GMT+2)
- 24-hour format: activated
4.6 Changing the system password
iThe system password grants access to all settings. The user password grants only limited access to the
settings.
• Open the settings.
• Select the menu “Advanced”.
• Select the “System password” submenu.
Password entry opens.
• Enter the current and new system password.
• Conrmpasswordswiththe“OK”button.
The system password is changed.
4.7 Updatingthermware
Prerequisite: Internet connection
• Select the app “System update”.
The app is started.
• Select “Search for updates online”.
Thermwareisupdatedautomatically.
iIfthereisnoInternetconnection,aUSBstoragemediumcanbeusedtoupdatethermware.

Page 9 of 16SC 0081 U
Operation
5 Operation
5.1 Operating elements
Fig. 5: Operation
Name Function
1 Proximity and brightness
sensor
For the automatic switch-on of the display and automatic
adjustment of the display brightness
2 Loudspeaker To play signal tones
3 Microphones To record speech
4 HOME button To return to the main menu (JUNG Launcher) and switch the
deviceo/on
Display main menu
• PresstheHOMEbuttonbriey1x.
The main menu (JUNG Launcher) is displayed.
Switchdeviceo/on
• KeeptheHOMEButtonpressedfor5seconds.
Theoperatingsystemispowereddownandthedeviceswitchedo.
• PresstheHOMEbuttonbriey1x.
The device is switched on and the operating system launches.
3
1
22
43

Page 10 of 16SC 0081 U
Operation
5.2 Control elements
Controlelementsareavailablefortheoperationandcongurationofthedevice.
The control elements are not displayed in all the menu areas and apps and can be hidden as necessary.
Fig. 6: Control elements
Name Function
A Status bar Display of the time
Display of status messages of launched apps
BNavigation bar Contains basic control elements
1O/Restart Torestartorswitchothedevice
2 Quieter To reduce the volume
3Back Goes back to the previous menu
4 Main menu Goes directly to the main menu (JUNG Launcher)
5 App overview Opens an overview of all launched apps
6 Louder To increase the volume
7 Context menu Opens the context menu
Opening the status bar
• Perform a swipe movement from the top edge of the touch screen to the centre
Status bar opens.
B
A
12 3 5 6 74
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels Junt Comprimé