Jung UDS 4 REG HE Manuel utilisateur

Universal dimming station 4-gang
Light Management
Universal dimming station 4-gang
Art.-No.: UDS 4 REG HE
Operating instructions
1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Failure to observe the instructions may cause damage to the device and result in fire and
other hazards.
Danger of electric shock. Always disconnect before carrying out work on the devise or
load. At the same time, take into account all circuit breakers that supply dangerous
voltage to the device or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage.
The load is not electrically isolated from the mains even when the device is switched off.
Do not connect any electronic lamps, e.g. switchable or dimmable compact fluorescent
lamps or LED lamps. Device can be damaged.
Fire hazard. For operation with inductive transformers, each transformer must be fused
on the primary side in accordance with the manufacturer's instructions. Only safety
transformers according to EN 61558-2-6 may be used.
These instructions are an integral part of the product, and must remain with the end
customer.
2 Device components
Figure 1: Device components
(1) Load outputs A1...A4
(2) Keypad for local control
(3) Button Prog, LED Prog
(4) Status LEDs for load outputs A1...A4
(5) Connection of control sections or control voltage
(6) Activation outputs A1'...A4' / Switching outputs E1 ON/OFF...E4 ON/OFF
(7) Connection Central ON/OFF
(8) Connection of hotel card switch
(9) Connection for mains supply
1/17
82577203
J:0082577203 31.05.2011

(10) DIN rail
Meaning of the LED in normal operation
Status LED (4) red and green light up. Initialisation of load output running
Status LED (4) green is illuminated.
Status LED (4) green off
Load output switched on
Load output switched off
Status LED (4) red flashes Control of load output via control section or
load output overtemperature
Status LEDs (4) red and green flash Short-circuit of load output
LED c Local control is switched on or
programming operation is switched on
LED ONn flashes Local control of load output, on, brighter
LED ON o flashes Local control of load output, off, darker
3 Function
Intended use
- Switching and dimming of incandescent lamps, HV halogen lamps and dimmable inductive
transformers or Tronic transformers with halogen lamps
- Suitable for mixed load up to the specified output (see section Technical data)
- Control by means of sensor modules, push-button modules, push-buttons 24 V, push-
button modules 24 V or unlit installation buttons.
- Installation in distribution boxes on DIN rail according to DIN EN 60715
i No mixed-load operation of Tronic and inductive transformers on the same load output.
Product characteristics
- Keypad for control of the dimmer station
- Control outputs A1'...A4' for activation of feedback LEDs on the control sections.
- Electronic short-circuit protection with permanent switch-off after 7 seconds at the latest
- Electronic over-temperature protection
- Switch-on brightness can be adjusted separately for each load output
- Switch-on brightness has been saved permanently.
- Bulb-preserving soft start
- Switch-off with dimming function
- Increase in output power possible through parallel switching of multiple outputs of a
dimmer station
- Power extension through power boosters (see power booster instructions)
- Connection for hotel card switch
- Central function Central ON, Central OFF
Common switching-on and switching-off of the load outputs
- Parallel switch of two dimmer stations or one dimmer station and one relay station
- Automatic setting of the dimming principle suitable for the load
Load type Electrical behaviour Dimming principle
Incandescent lamps ohmic Phase cut-off
HV halogen lamps ohmic Phase cut-off
Tronic transformers with
halogen lamps
capacitive Phase cut-off
Dimmable inductive
transformers with halogen
lamps
inductive Phase cut-on
i Flickering of the connected lamps due to undershoot of the specified minimum load or
through centralised pulses from the power stations. These are not device faults.
2/17
82577203
J:0082577203 31.05.2011
Light Management
Universal dimming station 4-gang

i Brief flickering upon load detection of ohmic loads. No operation is possible during load
detection.
Behaviour on failure and return of the mains power supply
If only the main power supply fails, then the status of the load output remain intact at first. The
dimmer station initialises when the mains power supply returns. All load outputs are switched off
after initialisation.
i During initialisation the dimmer station cannot be operated. The green and red Status
LEDs (4) of all the load outputs A1...A4 illuminate. Initialisation is complete as soon as all
the Status LEDs are off.
Behaviour on failure and return of the mains voltage on one or more load outputs
Should the mains voltage fail, the affected load outputs will switch off. When the mains voltage
returns, the affected load outputs will recalibrate themselves. During the calibration operation,
the green and red Status LEDs (4) illuminate and the load outputs cannot be operated. The load
outputs are switched off after calibration.
Function of hotel card switch
In combination with a hotel card switch, the light is switched on at switch-on brightness when
the hotel card is inserted. When the hotel card is removed, any switched-on lights remain
switched on for 1 minute and the dimmer station can be operated. When this time has elapsed,
the light is darkened within 3 minutes to minimum brightness and is then switched off. The
dimmer station can no longer be operated.
i Only load outputs to whom the central function has been assigned are switched on, whilst
all the load outputs are switched off.
4 Operation
Figure 2: Keypad local control
(4) Status LEDs for load outputs A1...A4 in normal operation
(11) Button c: Local control
(12) LED c on: Local control or programming mode active
(13) Button ON/n: Operate load output or select Master/Slave
(14) LED ON/n: Feedback LED, load output operation
(15) Button MODE : Programming mode
(16) Button OFF/o: Operate load output or select Master/Slave
(17) LED OFF/o: Feedback LED, operate load output
3/17
82577203
J:0082577203 31.05.2011
Light Management
Universal dimming station 4-gang

i If a hotel card switch is connected, the dimmer station can only be operated when the hotel
card is inserted.
Switch-on local control
o Press the c (11) button briefly.
Red status LED A1 (4) lights up, LED c (12) lights up.
The device is in local control.
Load output A1 can be controlled.
The green status LEDs (4) indicate the switching state of the load output. Status LED
illuminated: load output is switched-on, Status LED off: load output is switched-off.
Operating load outputs
Local control is switched on and the appropriate load output is selected.
Load output is switched off
o Press button ON/n (13) for less than 0.5 seconds.
Light switches to switch-on brightness.
o Press button ON/n (13) for longer than 0.5 seconds.
The light gets brighter up to maximum brightness. The LED ON/n (14) flashes for the
length of actuation
o Press button OFF/o (16) for longer than 0.5 seconds.
Light gets darker to minimum brightness. The LED OFF/o (17) flashes for the length of
actuation
o Press button OFF/o (16) for less than 0.5 seconds.
Light switches off.
o Press the c button briefly to go to the next load output.
The red status LED (4) of the next load output A2...A4 lights up.
The green status LED (4) indicate the switching state of the load output.
o Operate load output as described above.
Switching the light on with minimum brightness
Local control is switched on and the appropriate load output is selected.
Light is off.
o Press the OFF/o button for longer than 0.5 seconds.
Light switches on with minimum brightness. The LED OFF/o (14) flashes for the length of
actuation
i Alternatively, press the ON/n button for longer than 0.5 seconds. The light switches on
with minimum brightness and becomes brighter up to maximum brightness. The LED
flashes for the length of actuation.
Save switch-on brightness
Switch-on brightness can only be saved using the buttons on the dimmer station. A separate
switch-on brightness can be saved for each load output. In the state as supplied the maximum
switch-on brightness is saved.
Local control is switched on and the appropriate load output is selected.
o Set the light to the required brightness value (see above).
o Press both buttons ON/n (13) and OFF/o (16) for longer than 3 seconds.
The switch-on brightness has been saved permanently. The red status LED (4) flashes
twice as an acknowledgement.
The load output is reinitialised. The light is briefly switched off and switched on again at the
saved switch-on brightness. The red and green Status LEDs (4) illuminate.
i Saving the switch-on brightness again overwrites the old values.
4/17
82577203
J:0082577203 31.05.2011
Light Management
Universal dimming station 4-gang

Switching the load outputs centrally
All the load outputs to whom the central function has been assigned can be switched together.
As long as the Mode push-button is pressed, the system is switched from the operation of a
load output to central operation.
Local control is switched on.
o Press the Mode push-button and keep it pressed until the load outputs are switched.
The red Status LEDs (4), whose central function have been assigned to the load outputs,
illuminate.
Light is off.
o Press button ON/n (13) for less than 0.5 seconds.
Light switches to switch-on brightness.
o Press button OFF/o (16) for less than 0.5 seconds.
Light switches off.
i Central dimming is not possible.
Switching off local control
Local control is switched on.
o Keep pressing the c push-button, LED (12) c if off.
Local control is switched off.
When local control is switched off, the load outputs retain the switch position and
brightness previously set.
i After 15 s with no button being pressed, the device automatically switches local control off.
Operating using control sections
A load output is operated according to the two surface principle. One push-button, control
surface or installation button for switch-on and brighter and one push-button, control surface or
installation button for switch-off and darker. The individual load outputs are operated in the
same way as for local control. It is not possible to save switch-on brightnesses with control
sections. The red Status LED (4) of the operated load output flashes for as long as one control
section is actuated.
Central function via control sections
The functions Central ON and OFF have their own push-button, sensor surface or installation
button.
Central function has been assigned to the load outputs.
o Press the appropriate button, sensor surface or installation button for less than
0.5 seconds.
The light switches on or off at switch-on brightness.
5 Information for electrically skilled persons
5.1 Fitting and electrical connection
DANGER!
Electrical shock when live parts are touched.
Electrical shocks can be fatal.
Before carrying out work on the device or load, disengage all the
corresponding circuit breakers. Cover up live parts in the working environment.
Fitting the device
Observe the temperature range (see "Technical data"). Ensure sufficient cooling.
Output terminals up (figure 3).
5/17
82577203
J:0082577203 31.05.2011
Light Management
Universal dimming station 4-gang

i When operating multiple dimmers or power boosters in a sub-distribution, maintain a
distance of 1 module, approx. 18 mm, between the devices in order to prevent overheating.
o Mount device on DIN rail.
Connection: for operation with independent load outputs
Figure 3: Connection example: mains power supply, hotel card switch and loads
o Connect the mains power supply (figure 3).
o Connect the hotel card switch as shown in the connection example (figure 3).
i If no hotel card switch is used, then a outer conductor and the neutral conductor must be
connected directly.
o Connect loads as shown in the wiring example (figure 3).
Connection for operation with load outputs switched in parallel
Two to four load outputs can be switched in parallel for power extension. A load output is then
assigned to the Master of the additional load outputs as a Slave.
o Connect mains supply (9) as shown in the connection example (figure 4)
o Connect the hotel card switch as shown in the connection example (figure 4).
i If no hotel card switch is used, then a outer conductor and the neutral conductor must be
connected directly.
All load outputs are switched off.
Load outputs are not yet switched on.
DANGER!
Electrical shock when live parts are touched.
Electrical shocks can be fatal.
Use only insulated tools when working on the device! Cover up live parts in the
working environment.
o Switch on mains voltage.
All the LEDs illuminate briefly.
LED Prog lights up red.
o Insert the hotel card in the hotel card switch.
LED Prog lights up green.
o Press the push-button Prog (3) until LED Prog (3) flashes alternately in red and green.
6/17
82577203
J:0082577203 31.05.2011
Light Management
Universal dimming station 4-gang

Programming mode is switched on. In this operating mode, the push-buttons of the button
panel (2) are assigned to the load outputs according to the table.
Load output A1 c
Load output A2 MODE
Load output A3 ON/n
Load output A4 OFF/o
In general, any load output can be specified as the Master. The first selected load output is the
Master to which any other load outputs are assigned as Slaves. A maximum of two Masters
may be specified. In this case, a Master is first specified with a Slave and then the steps
repeated for the second Master.
o Press the push-button of a load output and keep it pressed during Slave assignment.
The green status LED (4) of the load output lights up. The load output is specified as the
Master.
o Briefly press the push-button of another load output.
The load output is assigned to the Master as a Slave. The red status LED (4) of the load
output lights up.
i To delete the assignment, press the push-button of the Slave again. The red status LED
(4) goes out.
o If necessary, briefly press the push-button of another free load output.
The load output is assigned to the Master as a Slave. The red status LED of the load
output lights up.
o Release the push-button of the Master.
The green Status LED of the Master illuminates.
Two further load outputs are available.
o Optionally, carry out the second Master-Slave assignment as described above.
o Press the Prog push-button until all the LEDs illuminate briefly.
The red Status LEDs illuminate briefly.
Assignments are saved. The dimmer station reinitialises itself.
i During initialisation, firstly the green and red Status LEDs (4) of all the load outputs A1...A4
illuminate. Initialisation is complete as soon as all the Status LEDs are off.
o Switch off mains voltage.
7/17
82577203
J:0082577203 31.05.2011
Light Management
Universal dimming station 4-gang

Connecting loads to load outputs switched in parallel
Figure 4: Connection example of load outputs switched in parallel
CAUTION!
Risk of destruction of load outputs switched in parallel if the device is set
incorrectly.
Dimmer and loads may be destroyed.
Specify the Master and the Slave before connecting the loads to the load
outputs.
CAUTION!
400 V are shorted when outputs switched in parallel are connected to different
outer conductors.
The device will be destroyed.
Always connect outputs switched in parallel to the same outer conductor.
CAUTION!
When connecting power extensions to load outputs switched in parallel, there
is no guarantee that the dimmer sets the dimming principle suitable for the
load.
Dimmer, power extension and load may be destroyed.
Do not connect any power extensions to load outputs switched in parallel.
Only subject load outputs switched in parallel to up to 80%.
The minimum load of parallel switching of load outputs is 150 W.
Example
Load output Connected load
A1 20...150 W/VA
A1+A2 150...240 W/VA
A1+A2+A3 150...360 W/VA
A1+A2+A3+A4 150...480 W/VA
o Connect loads as shown in the connection example.
8/17
82577203
J:0082577203 31.05.2011
Light Management
Universal dimming station 4-gang

Connecting a control section
Operation take place using the devices listed under Accessories.
In case of operation with sensor modules (19) or push-button modules (19) do not connect any
other control sections such as push-buttons (24 V) (18), push-button modules 24 V (18) and
unlit installation buttons (20), to the dimmer station.
Observe technical data, especially the maximum number of sensor modules and push-button
modules, load capacity of the activation outputs and switching inputs.
o Connect the control section as shown in connection example (figure 5), (figure 6) or
(figure 7).
Figure 5: Connection example of push-button 24 V, 4x, push-button module 24 V, 4x
Figure 6: Connection example for sensor module or push-button module
9/17
82577203
J:0082577203 31.05.2011
Light Management
Universal dimming station 4-gang

Figure 7: Wiring example for unlit installation button
Operation of two dimmer stations with a sensor module or push-button module
Sensor modules or push-button modules can operate two dimmer stations together. This
requires connection of both dimmer stations in parallel. To do this, the sensor modules must
have at least release version R2. The device address of a dimmer station must be changed
(see "Setting the device address")
Figure 8: Connection example for one sensor module or push-button module to two dimmer
stations
o Connect the sensor module or push-button module to two dimmer stations according to the
connection example (figure 8).
i Connect the power supply of the dimmer stations to the same outer conductors.
i Even dimmer stations switched in parallel may only have four sensor modules or push-
button modules connected to them.
Operation of multiple dimmer stations with a push-button 24 V or push-button module 24
V
In operation with push-button 24 V or push-button module 24 V, they can be connected to up to
four dimmer stations. To do this, the negative poles of the individual dimmer stations have to be
connected to each other. It is possible, for example to switch load outputs of several dimmer
10/17
82577203
J:0082577203 31.05.2011
Light Management
Universal dimming station 4-gang
Table des matières
Autres manuels Jung Variateur