joule Pulsa PV Manuel utilisateur

PULSA PV
joule pulsa pv solar high performance ac solar module installation guide


Please complete this warranty card and return
it to Joule to activate the warranty.
Installer Name .................................................................................................................
Company Name .................................................................................................................
Address .................................................................................................................
.................................................................................................................
.................................................................................................................
Contact Tel. no. ......................................... Contact Email ..........................................
Client Name .................................................................................................................
Site Address .................................................................................................................
.................................................................................................................
.................................................................................................................
Contact Tel. no. ......................................... Contact Email ..........................................
Unit purchased from ......................................... Date purchased ..............................
Installation date .........................................
Inverter Serial No’s. .............................. Inverter Serial No’s. ..............................
Inverter Serial No’s. .............................. Inverter Serial No’s. ..............................
Inverter Serial No’s. .............................. Inverter Serial No’s. ..............................
Inverter Serial No’s. .............................. Inverter Serial No’s. ..............................
Inverter Serial No’s. .............................. Inverter Serial No’s. ..............................
Inverter Serial No’s. .............................. Inverter Serial No’s. ..............................
Scan the page or alternatively take a photo with smart phone of complete sheet with all
information lled in.
This must be completed by the installer and a copy sent to Joule -


Table of Contents
6 Why Install Photovoltaic Solar Panels?
7 Contribution to Running Costs
8 Advantages
9 Features
10 Maximising Performance
11 Transportation and Installation Notes
12 Safety Instructions
General Safety
Handling Safety
Installation Safety
13 Fire Safety
14 TechnicalSpecication
16 Mechanical Installation
Select suitable locations for installation
Components supplied
17 Installation
19 Locating the Inverter
Installing Branch Connectors
20 Electrical Installation
Lightning Surge Protection
Selecting Engage Cable Type
21 Installation Procedure
Step 1 - Measure AC at the Electricity Network connection
22 Step 2 - Install the AC Branch Circuit Junction Box
23 Step 3 - Position the Enphase Engage Cable
Step 4 - Attach the Microinverters to the Mounting Rail
24 Step 5 - Dress the Engage Cable
26 Step 6 - Terminate the Unused End of the Engage Cable
29 Step 7 - Connect the Engage Cable to AC Junction Box(es)
31 Electrical Installation - Microinverter
32 Technical Specication
34 Electrical Installation
35 Engage and Wire Sizing Overview
What Contributes to Voltage Rise
36 Sample Calculation
38 Voltage Rise for M215s with the 230V Engage Cable
39 Step 8 - Verication and Commissioning
40 Maintenance
41 Replacing a Microinverter

Why Install Photovoltaic Solar Panels?
Since the revisions to Part L of the Building Regulations in March 2014 there has been
a need for a greater contribution from renewable sources of energy for domestic and
commercial constructions. One way to comply with the updated regulations is by in-
stalling Photovoltaic (PV) Solar Panels.
There are numerous benets to installing PV Solar Panels
• PV panels provide clean, green energy. During electricity generation with PV pan-
els there is no harmful greenhouse gas emissions thus solar PV is environmentally
friendly.
• Solar energy is energy supplied by nature – it is thus free and abundant!
• Solar energy can be made available almost anywhere there is sunlight
• Photovoltaic panels, through photoelectric phenomenon, produce electricity in a
direct electricity generation way.
• Operating and maintenance costs for PV panels are considered to be low, almost
negligible, compared to costs of other renewable energy systems.
• PV panels have no mechanically moving parts, except in cases of sun-tracking
mechanical bases; consequently they have far less breakages or require less main-
tenance than other renewable energy systems (e.g. wind turbines).
• PV panels are totally silent, producing no noise at all; consequently, they are a per-
fect solution for urban areas and for residential applications.
6
Locating the Unit

Contribution to Running Costs
The table below gives typical consumptions of standard electrical devices. Even when
electrical devices are turned o they may still be consuming power. Photovoltaic Solar
Panels can contribute towards the operation of these products with the contribution
given being determined by the amount of panels installed.
Customers may start with as little as one PS260AC Module and then increase their system
wattage as budget, time, and space permit. As each Photovoltaic AC module produces grid
compliant AC current, the modules serve as building blocks with no matching or string sizing
required.
The integrated Enphase Microinverter instantly converts DC electricity into ready to use AC
power. If an Enphase Envoy is installed, the intelligent Microinverter also sends vital health
and performance information to the Enphase communications gateway.
7
PULSA PV
installation manual

Advantages
This next generation design eliminates the need for expensive DC wiring components
and centralized power inverters. Also, the Photovoltaic AC Module dramatically re-
duces the complex design and installation process associated with a traditional DC
solar power system.
AC Advantages
• High eciency solar module integrated with an Enphase Microinverter, the world’s
most ecient AC system solution
• Higher Eciencies than String Inverter systems
• Optimized for higher outputs in low light conditions
• Modules are individually optimized
• Eliminates module mismatch losses
• Any shading will aect only the shaded panel, not the entire system
• Easier to Design and Install
• Installation labour reduced, no DC switches, GFCI, etc. required
• Fast, inexpensive mounting - delivered ready for connection
• Pre manufactured cables
• Greater Productivity with more reliability
• AC wiring systems are more ecient at transporting electricity as they do not suer
typical electrical losses that are common in all DC wiring circuits.
• More uptime means more kW-h generated
• Installers need not match PV output characteristics before installation
• Better Performance
• Individual PV breakages (e.g. hail) do not stop system power output
• No system mismatch losses
• Any shading will aect only the shaded panel, not the entire system
• Optional communication hub monitors every module independently
• Peak eciency 96.3%, CEC eciency 96%
• No single point of failure will disable the system
• AC Modules are sealed. No cooling vents mean that the units always stay clean
and dry inside
• Convection cooled with no moving parts
• Safer – no DC-side wiring (eliminates dangerous high voltage DC and all DC wiring
loss)
• Reduced inspection code issues
8
Locating the Unit

Features
9
PULSA PV
installation manual
Up to 17% module eciency
Outstanding performance in weak-
light conditions
Excellent temperature coecient
giving higher yields in the long term Fire test certication
Salt mist corrosion certication
Ammonia corrosion certication
Durability assured
10-year product warranty
25-year performance warranty
Certied to withstand increased
loads of up to 5400Pa
IP68 connectors enhance the reli-
ability of the PV system
A+ class in PI Berlin test
Positive current sorting
Advantages

Maximising Performance
10