Jecod DCP-3000 Manuel utilisateur

DC Pump
OWNER’S MANUAL
DCP-3000
,
DCP-4000
,
DCP-5000
,
DCP-6500, DCP-8000,
DCP-10000
,
DCP-15000
,
DCP-18000
,
DCP-20000
Introduction
The DCP pumps are carefully inspected and tested to ensure both safety and operating
performance. However, failure to follow the instructions and warnings in this manual
may result in pump’s damage and/or serious injury. Be sure to read and save this
manual for future reference.
Pump Features
●High performance with innovative motor, and energy saving up to 65%, super
quiet operation.
●IC electronic detection, automatic power-off protection upon no water.
●No-copper element.
●Suitable for both marine and fresh water, Rust free.
●With anti-resistant ceramic shaft, Longer operation file.
Controller Features
●Adjustable the flow rate and head max.
●“Feed” Model, pause, timing, delay, restart function
●Memory function, ensure that the pump rework upon keeping the same parameter
Operating instructions
1. The pump must be connected with the controller and the 24V or 36V adaptor
correctly before work
2. Lock / unlock function: press the "+" or "-" button for three seconds until the LED
light flash for two times, the controller locked; Similarly, press the "+" or "-" button for
three seconds again, LED indicator light flashes for two times, the controller unlocked
3. "FEED" function: when the pump is working, press "FEED" button, pump stops
working, the "10min" indicator lights up, the pump reworks automatically at previous
level after 10 minutes. Or you can press the “FEED” button to make the pump rework.
Control and Panel Function
First, LED display and controller key Instructions
As indicated in able diagram LED indicates power work/stop and fault code, the panel
are touched control
Seconds, operating instructions
After connected with pump, the control is set per last operation, panel is shown on LED,
touch work /stop button, the pump will stop working, and OFF indicate in LED. Touch
work/stop button again, the pump resume working, Led shows normal locking panel.
PXXX is shown in LED, P is short for power, there are 71 settings for working panel,
when touch slow/fast button, LED will show the instant working condition, you can set
different power per your need. When sets “watts “ button the Led display the “watts”
button were “FXX,button from 30 to 100”,SP is Speed shortening. More than 1 S no
setting “watts” button, the led auto change its display “watts” button.
Three, the key Lock Function
Turn on the power, press the "+" or "-" button for three seconds until the LED light
flash for two times, the controller locked; Similarly, press the "+" or "-" button for three
seconds again, LED indicator light flashes for two times, the controller unlocked
Four, The Led protected mode
Turn on the power , more than 25 seconds no touch control button, the LED to micro
bright, the controller enter the screen saver mode; the led return to normal When press
any button.

Five, Date memory function
Memory function, ensure that the pump rework upon keeping the same parameter.
Six, Fault code and description
The fault code abnormal and flashing when the controller abnormal work, the code
explanation is as below:
Er01: Abnormal Working current;Check if the pump short of voltage or the controller
broken
Er02: Controller overheating; Check whether the controller exposed to the sunshine or
in high temperature environment
Er03: Pump idling;Check the pump work dry
Er04: The impeller stops running; Check if the pump short of voltage or the controller
broken
Er05: Abnormal Working voltage. Check the input supplying voltage
●Note: for indoor use, the power socket must be installed with the leakage current
protecting device, and the leakage current shall not exceed 30mA (please the consumer
to install the leaking current protection device by themselves).
Performance Parameters Table
No:
Model No:
Voltage
Consumption
(W)
Flow rate (L/H)
Head Max (M)
1
DCP-3000
DC 24V
25
3000
2.8
2
DCP-4000
DC 24V
33
4000
3.5
3
DCP-5000
DC 24V
40
5000
3.5
4
DCP-6500
DC 24V
55
6500
4.5
5
DCP-8000
DC 24V
65
8000
5.2
6
DCP-10000
DC 24V
80
10000
6.0
7
DCP-15000
DC 24V
105
15500
6.2
8
DCP-18000
DC 36V
145
18000
7.5
9
DCP-20000
DC 36V
175
20000
8.0
WARNING
l Do not connect to any other power supply over the rated voltage
l Do not put the pump in the flammable liquid.
l Do not use the pump in the water temperature above 35℃.
l Maximum water depth 1.5M
l Maximum head Max please see the parameter table.
l Do not immerse the plug into water or other liquid.
l This appliance is not allowed to use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
l Children should be supervised to ensure that they do not play with the
appliance.
l This appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards
involved.
CAUTION
Always disconnect the pump from the power supply before cleaning, maintenance and
handling.
Do not let the pump work dry.
Do not lift the pump by holding the power cord only
Do not use the pump in the heating liquid.
The pump fits for fresh water and sea water only
The pump can used as submersible pump and used as non-submersible, pump house
must be filled with water.
The pump can not run in the swimming pool.
Automatic shut off if no water for 2 minutes.
Pull the plug out, and re-insert for resuming work
Operation
A clogged or dirty intake screen will reduce the performance.
If the pump is used on a dirty surface, raise it slightly to reduce the amount of debris
contacting the intake. If the flow is low, please adjust the regulator on the sealing cover.
Do not let the pump run in dry. The pump will be broken easily. Normally, put the
pump into water, plug on. At the beginning, it probably can’t pump water, because
there is air in the pump and the connector fitting. Don’t worry. Please plug on and off
for several times. it will work normally.

Used as submersible pumps
IMPORTANT: Do not let the pump run dry – this could cause
damage to the motor.
l Submerse the pumps completely in your pond so as to make the pump body fill
with water.
l A water level of approx. 15 cm (6 in.) is required for submersible use in order to
prevent the pump from taking in air.
l To prevent the filter becoming prematurely clogged, place the fountain pump
above the mud in the pond!
l Install the enclosed filter sponge to prevent the fountain inlet from becoming
clogged.
l Running in conjunction with fountain jets, the pump should be stationed firmly
and horizontally (on a brick).
l The pump can be switched on by simply plugging it in and switched off by
plugging off.
Used as non-submersible pumps
l Position the pump lower than the water surface on the side of the pond so that the
water can be drained to the pump because it is not self-priming.
l Remove the filter cover and connect suction hose (A: inlet) and pressure hose (B:
outlet) from the pump. The connection should be waterproof.(see Figure 1)
l Fill the suction hose and pump with water before turning it on.
l To prevent the pump from becoming clogged, provide the suction hose with an
adequate suction filter.
l Never let the pump run dry.
Installation diagram:
Figure 1
Figure 2
MAINTENANCE
To clean the pump, remove the back cover, sealing cover and the impeller.
Use a small brush or stream of water to remove any debris.
If the pump not work, check as following:
l Check the circuit. Please try to plug on another power socket, to ensure the pump
switched on with power. Note, please do not plug on before operation.
l Check the pump outlet and tube, if blocked by dirty. Algae may block them, up i
can clean the algae using the pond water with a garden hose.
l Check the inlet to ensure not clogged by debris.
l Remove the pump inlet to access the impeller. Turn around the rotor to check if
broken or jammed.
l Monthly maintenance will prolong your pump’s life. Clean the rotor, remove the
dirt. etc
NOTE: Ensure the electrical cord loops below the power socket like a “Drip
Loop”. It will prevent the water from running around the cable into the power
socket
DISPOSAL:
Do not dispose this product as unsorted municipal waste. Collection
of such waste separately for special treatment is necessary. This
product must not be disposed together with the domestic waste. This
product has to be disposed at an authorized place for recycling of
electrical and electronic appliances. By collecting and recycling waste, you help
save natural resources, and make sure the product is disposed in an environmental
friendly and healthy way.
Jecod Co.,Ltd
Tongmao Industrical Park, Dongsheng Town, Zhongshan, Guangdong. China.
Email: info@jecod.com Website: www.jecod.com
Tel: +86-760-28136717/19/20 Fax: +86-760-28136725
Outlet
Screw Nut
Controller Adaptor
Holder
Rubber
Pump Body
Pump Cover Rotor
O-Ring
O-Ring
Inlet
WATTS
DCP-200W
Pump Controller
A
B
Ce manuel convient aux modèles suivants
8
Table des matières
Autres manuels Jecod Pompe à eau
Manuels Pompe à eau populaires d'autres marques

Sykes AmeriPumps
Sykes AmeriPumps GP100M Guide de dépannage

DUROMAX
DUROMAX XP WX Series Manuel utilisateur

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Manuel utilisateur

Franklin Electric
Franklin Electric IPS Manuel utilisateur

Xylem
Xylem e-1532 Series Manuel utilisateur

Milton Roy
Milton Roy PRIMEROYAL Manuel utilisateur