IXOM Medora F8 Manuel utilisateur

© 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | [email protected]
O&M_F8_10335_20201026a
F8 Ventilation Blower
Owner's Manual

Table of Contents
About Ixom
Ixom combines knowledge and experience from across the water quality spectrum to help solve
real-world problems. Whether in Lakes, Stormwater Retention Ponds, Raw Drinking-Source Reservoirs, Water
Treatment Plants, Potable Storage Tanks, or Wastewater Treatment Processes, Ixom equipment continues to
be at the forefront as the #1 world leader for in-situ water body treatment.
© 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | [email protected]
Table of Contents
10014_20200528
F8 Ventilation Blower
Owner's Manual
Safety 1
Technical Specifications 4
Performance Curves 5
Exploded Parts Diagram 6
Placement 7
Startup and Operation 10
Maintenance 12
Warranty 13
Customer Service 14
O&M_F8_10335_20201026a

Carefully read safety information when you see
any safety symbols.
Be sure you have read all installation, operation, maintenance and safety instructions before
you install, service or begin to operate this unit.
Accidents occur every year because of careless use of industrial equipment. You can avoid hazards
by following these safety instructions, and applying some ordinary common sense when operating or
servicing this unit.
Keep in mind that full operator attention and alertness are required when operating or servicing
this unit.
USE COMMON SENSE!! Most accidents can be avoided by using common sense and
concentration on the job being done.
© 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | [email protected]
Safety
Safety
1949_10036_20200528 O&M_F8_10335_20201026a - 1

IMPORTANT!!!
Follow all federal and state laws in regards to
safety regulations of working at heights, conned
spaces, rescue, etc. as required by the U.S.
Department of Labor, Occupational Safety and
Health Administration. Use necessary PPE when
placing and servicing this unit.
Identify all possible hazards. Determine what
safeguards are needed and implement them.
Only you, the user, understand your product
and system characteristics fully. The ultimate
responsibility for safety is with you. Your
safety ultimately rests in your hands. Do
your part and you will enjoy safe, trouble free
operation for years to come. This instruction
manual is not intended to include a
comprehensive listing of all details for all
procedures required for placement, operation
and maintenance. If you have a question about
a procedure or are uncertain about any detail,
Do Not Proceed. Please contact Ixom
Customer Service at 866-437-8076 to speak
to a representative.
ELECTRICAL HAZARD
WARNING: THIS EQUIPMENT CONTAINS
HIGH VOLTAGE! ELECTRICAL SHOCK CAN
CAUSE SERIOUS OR FATAL INJURY. ONLY
QUALIFIED PERSONNEL SHOULD ATTEMPT
PLACEMENT, OPERATION AND MAINTENANCE
OF ELECTRICAL EQUIPMENT. REMOVE ALL
SOURCES OF ELECTRICAL POWER BEFORE
PERFORMING ANY SERVICE WORK TO THE
MACHINE. USE PROPER LOCKOUT TAGOUT
(LOTO) PROCEDURES TO ENSURE A SAFE
WORK ENVIRONMENT.
Rotating Hazard
CAUTION: KEEP BODY APPENANDAGES OR
LOOSE CLOTHING AWAY FROM EQUIPMENT
WHILE OPERATING. ENSURE EQUIPMENT IS
OFF BEFORE ATTEMPTING SERVICE.
Crush Hazard
WARNING: DO NOT REMOVE ANY FLOAT
ASSEMBLY BOLTS OR PINS WHILE EQUIPMENT
IS FLOATING IN WATER. EQUIPMENT MUST BE
SECURELY SUPPORTED BEFORE PERFORMING
SERVICE.
Laceration Hazard
CAUTION: EDGES MAY BE SHARP AND CAUSE
LACERATION IF PROPER CARE IS NOT USED.
Entanglement Hazard
WARNING: ENSURE THAT PERSONNEL ARE
CLEAR OF THE ELECTRIC CORD AND CHAIN TO
AVOID ENTANGLEMENT.
Thin Ice Hazard
WARNING: ICE SURROUNDING MACHINE MAY
NOT SUPPORT WEIGHT, KEEP CLEAR OF THIN
ICE.
© 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | [email protected]
Safety
Safety
1949_10036_20200528 O&M_F8_10335_20201026a - 2

Permit-Required
Conned Spaces
A conned space has limited openings for
entry or exit, is large enough for entering and
working, and is not designed for continuous
worker occupancy. Conned spaces include
underground reservoirs, ground storage tanks,
elevated tanks, silos, manholes, and pipelines.
Conned Space Tips
• Do not enter permit-required conned spaces
without being trained and without having a
permit to enter.
• Review, understand and follow employer’s
procedures before entering permit-required
conned spaces and know how and when
to exit.
• Before entry, identify any physical hazards.
• Before and during entry, test and monitor for
oxygen content, ammability, toxicity or
explosive hazards as necessary.
• Use fall protection, rescue, air monitoring,
ventilation, lighting and communication
equipment according to entry procedures.
• Maintain contact at all times with a trained
attendant either visually, via phone, or by
two-way radio. This monitoring system
enables the attendant and entry supervisor
to order you to evacuate and to alert
appropriately trained rescue personnel to
rescue entrants when needed.
Refer to 29 CFR 1910.146 for complete
regulations set by OSHA. Refer to your state's
regulations if your state established and operates
their own safety and health programs approved
by OSHA.
Protect Yourself
It is important that you comply with all relative
OSHA and local regulations while installing
and performing any maintenance to the mixer
circulation equipment.
Key OSHA Compliance Standards that must
be followed (and not limited to) are:
• 1910.146 Permit-required conned spaces
• 1910.147 Lockout/Tagout
• 1926.500 Fall Protection
Fall Protection Tips
• Identify all potential tripping and fall hazards
before work starts.
• Look for fall hazards such as unprotected
oor openings/edges, shafts, open hatches,
stairwells, and roof openings/edges.
• Inspect fall protection and rescue equipment
for defects before use.
• Select, wear, and use fall protection and
rescue equipment appropriate for the task.
• Secure and stabilize all ladders before
climbing.
• Never stand on the top rung/step of a ladder.
• Use handrails when you go up or down stairs.
• Practice good housekeeping. Keep cords,
welding leads and air hoses out of walkways
or adjacent work areas.
Refer to 29 CFR 1926.500 for complete
regulations set by OSHA. Refer to your state's
regulations if your state established and operates
their own safety and health programs approved by
OSHA.
Lockout Tagout
When the On/Off switch is in the "ON" position,
the mixer may start up at any time if not already
operating. The mixer's On/Off switch can be
locked out by placing a pad lock thru the door latch
of the controller after the switch has been turned
to the "OFF" position. The On/Off switch is to be
used as the emergency stop.
© 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | [email protected]
Safety
Safety
1949_10036_20200528 O&M_F8_10335_20201026a - 3

Technology Description- Centrifugal blower and lter housing assembly with electric motor. Filtered air intake, distributes
air inside tank for ventilation of tank head space, designed to evacuate volatilized THM’s, gases and other contaminants
from the head space.
Figure 1: F8 Blower
Electrical Requirements - Requires 480VAC three-phase, 60Hz power. Ixom recommends secondary disconnect
to be located near blower equipment. For three-phase motors, three-phase motor protection is recommended. All
conduit, conductors, switches, breakers, emergency stop buttons, control panels and other controls shall be installed in
accordance to all NEC, State, and local regulations. (Not supplied by Ixom.)
Subject to change without notice.
Maintenance / Warranty - Limited maintenance. Limited 2-year warranty. See GridBee THM Removal Systems Limited
Replacement Warranty for more details.
Air Filters - Six Filter Elements, 98%+ removal efciency to
10 micron, synthetic felt air lter. Each rated for 3000 CFM
(85 m3/min), 30ft2 surface area, washable, galvanized steel
reinforcement frame Dimensions: 24” X 24” X 2”
Replacement Filters PN: 20012066
Mounting - Ground mount or roof mount congurations available.
Wiring - 4-conductors required (L1, L2, L3, Gnd). Electrical TEFC motor wiring box for conduit connection and
electrical splicing. Multiple locations available for conduit entry through air lter housing.
Motor - 3HP Baldor TEFC, wash down duty induction motor, designed for continuous operation, low power
requirement, direct drive, no gearbox and no lubrication schedule required. No heater.
Materials of Construction - T316 stainless steel, with gray
epoxy or powder coating.
Air Flow Rate - 3000 cubic feet per minute (85 cubic meters
per minute) at 4” (10 cm) of H2O. Tank gravity vents must al-
low for 240 sq-inch (after screens and mesh) minimum open
surface area per blower.
Shipping Size / Weight
• Crate - 86in x 86in x 64in (2.2 m x 2.2 m x 1.6 m) / 1500 lbs (680 kg). Exact weight and dimensions may vary
dependent on blower and roof mount conguration.
Vibration Isolation - Secured to T316SS skid, separated by
rubber isolation pads properly sized for blower weight and
operation.
Coupling and Bearings - Double supported fan wheel using quality Baldor Dodge pillow block bearings and
coupling.
Part Number - 100716
Duct Sizing Requirement - Ø 18” minimum or equivalent
open space. (Ø 24” recommended.)
© 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | [email protected]
Technical Data Sheet
F8 Ventilation Blower
2030_10194_20200804 O&M_F8_10335_20201026a - 4

7.5 HP
3 HP
© 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | [email protected]
Blower Performance
F-SERIES BLOWER PERFORMANCE CURVES
2093_10330_20200402 O&M_F8_10335_20201026a - 5

Medora Corporation | www.medoraco.com | 866 - 437 - 8076 | [email protected]
15
Exploded Parts Diagram
F8 BLOWER
Exploded Parts Diagram
General Notes:
ITEM QTY PART # DESCRIPTION
1 1 100631 Motor, 3 HP TEFC, Wash Down Duty , Blower Fan
2 1 100632 Coupling Bushing, 1.125”, Fan to 3 HP Motor Connection
3 2 100588 Coupling Flange, Fan to 7.5 HP Motor (With Bolts)
4 1 100587 Coupling Element, Fan to 7.5 HP Motor Connection
5 1 100590 Coupling Bushing, 1.5”, Fan to 7.5 HP Motor Connection
6 1 100592 Bearing, 1.5”, Pillow Block, Fan
7 1 100604 Shaft Blower Fan
8 1 100635 Fan Wheel Assembly, Blower
9 1 100603 Fan Wheel Hub, Blower
10 1 100615 Panel, Fan Access
11 1 100591 Bearing, 1.5”, Four Bolt Flange, Fan
12 6 20012066 Filter Element
13 6 100610 Filter Intake Covers
14 4 100159 Anti-Vibration Pads
15 4 ----------------- Bearing Grease Spots - See Maintenance Page
MOTOR EXPLODED DETAIL VIEW
2034_10200_20201026 O&M_F8_10335_20201026a - 6

UNIT WEIGHT
1400 LBS APPROX.
MINIMUM EIGHT (8) ANCHORS USED
3/8” THREADED ROD WITH SIMPSON
STRONG-TIE SET IN HIGH STRENGTH
EPOXY AT 3” EMBEDMENT DEPTH
OR
3/8” REDHEAD CONCRETE WEDGE
ANCHOR BOLTS AT 3” OR GREATER
EMBEDMENT DEPTH
NOTE: 8’ L x 8’ W x 6” OR GREATER
PAD IS GENERALLY USED.
TOP VIEW
FRONT VIEW
SIDE VIEW
14.00”
© 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | [email protected]
F-SERIES BLOWER INTEGRATION
2033_10203_20201026 O&M_F8_10335_20201026a - 7

DISCHARGE DETAIL
VIBRATION PAD DETAIL
Concrete Pad *Vibration Pad may
compress 1/4” on
average
Ø.375 x 1.00” SLOT
12 PLCS
© 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | [email protected]
F-SERIES BLOWER INTEGRATION
2033_10203_20201026 O&M_F8_10335_20201026a - 8
Table des matières