ITRON OpenWay Riva Manuel utilisateur

OpenWay® Riva
Gas Remote Disconnect
Installation Guide
Technical
Communications
knowledge to shape your future

Identification
OpenWay® Riva Gas Remote Disconnect Installation Guide
24 January 2018
TDC-1759-000
Copyright
© 2018 Itron, Inc. All rights reserved.
Confidentiality Notice
The information contained herein is proprietary and confidential and is being provided
subject to the condition that (i) it be held in confidence except to the extent required
otherwise by law and (ii) it will be used only for the purposes described herein. Any third
party that is given access to this information shall be similarly bound in writing.
Trademark Notice
Itron is a registered trademark of Itron, Inc.
All other product names and logos in this documentation are used for identification purposes
only and may be trademarks or registered trademarks of their respective companies.
Suggestions
For more information about Itron or Itron products, see www.itron.com.
If you have questions or comments about the software or hardware product, contact Itron
Technical Support Services.
Contact
• Email: [email protected]
• Internet: support.itron.com
• Telephone Itron Technical Support North America: 1-877-487-6602
For technical support contact information by region, go to www.itron.com and select your
country and language.

Contents
Chapter 1 Important Safety and Compliance Information.............................. 1
USA, FCC Part 15 compliance............................................................................................................................. 1
Canada, ISED compliance.................................................................................................................................... 2
RF Exposure (FCC/ISED)...................................................................................................................................... 2
Electromagnetic compatibility...............................................................................................................................2
Telemetering equipment classication..................................................................................................................3
Intrinsic safety.......................................................................................................................................................3
Lithium battery...................................................................................................................................................... 3
Transportation classication................................................................................................................................. 3
Modications, repairs, installation, and removal...................................................................................................3
Aluminum enclosure............................................................................................................................................. 4
Electrostatic discharge..........................................................................................................................................4
Electrostatic ignition hazard..................................................................................................................................4
Device cleaning.....................................................................................................................................................4
Do Not Drop .........................................................................................................................................................4
Product notication...............................................................................................................................................5
Chapter 2 OpenWay Riva Gas Remote Disconnect Installation Guide
Overview............................................................................................................ 6
Audience............................................................................................................................................................... 6
Chapter 3 About the OpenWay Riva Gas Remote Disconnect .......................7
OpenWay Riva Gas Remote Disconnect models................................................................................................. 7
OpenWay Riva Gas Remote Disconnect system security.................................................................................... 8
Enabling OpenWay Riva Gas Remote Disconnect security....................................................................... 8
Transmission mode............................................................................................................................................... 8
Operational states.................................................................................................................................................8
OpenWay Riva Gas Remote Disconnect functional specications...................................................................... 9
OpenWay Riva Gas Remote Disconnect operational specications.................................................................... 9
Related documents.............................................................................................................................................10
Chapter 4 Installing the OpenWay Riva Gas Remote Disconnect................ 11
Initial calibration and alignment.......................................................................................................................... 11
OpenWay Riva Gas Remote Disconnect installation, commissioning, and decommissioning ......................... 12
OpenWay Riva Gas Remote Disconnect accessories........................................................................................ 12
Meter set installation...........................................................................................................................................13
OpenWay Riva Gas Remote Disconnect valve positions.........................................................................14
Installing the OpenWay Riva Gas Remote Disconnect in the pipe.......................................................... 14
Installing the ood sensor........................................................................................................................ 15
Mounting the ood sensor on the pipe.............................................................................................16
Mounting the ood sensor on a at surface..................................................................................... 16
Chapter 5 Connecting the Flood Sensor to the OpenWay Riva Gas
Remote Disconnect........................................................................................ 18
OpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 iii
Proprietary and Confidential

Connecting the ood sensor inline connector to the OpenWay Riva Gas Remote Disconnect.........................18
Chapter 6 OpenWay Riva Gas Remote Disconnect Programming...............20
Sending OpenWay Riva Gas Remote Disconnect secure commands............................................................... 20
Get Commands........................................................................................................................................20
Performing a Get Commands........................................................................................................... 20
Commissioning the OpenWay Riva Gas Remote Disconnect................................................................. 21
Performing an OpenWay Riva Gas Remote Disconnect valve commissioning................................ 21
Connecting the OpenWay Riva Gas Remote Disconnect........................................................................21
Connection instructions.................................................................................................................... 21
Disconnecting the OpenWay Riva Gas Remote Disconnect................................................................... 22
Closing the OpenWay Riva Gas Remote Disconnect valve to disconnect service.......................... 22
Decommissioning the OpenWay Riva Gas Remote Disconnect..............................................................23
Decommissioning instructions..........................................................................................................23
OpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 iv
Proprietary and Confidential

Chapter 1 Important Safety and Compliance
Information
This section provides important information for your safety and product compliance.
USA, FCC Part 15 compliance
This device complies with Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation.
Operation is subject to the following two conditions:
• This device may not cause harmful interference.
• This device must accept any interference that may cause undesirable operation.
This device must be installed to provide a separation distance of at least 20 centimeters (7.9
inches) from all persons to be compliant with regulatory RF exposure.
USA, FCC Class B-Part 15
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
• Consult the dealer or an experienced radio or TV technician for help.
Modifications and Repairs
To ensure system performance, this device and antenna shall not be changed or modified
without the express approval of Itron. Per FCC rules, unapproved modifications or operation
beyond or in conflict with these instructions for use could void the user's authority to operate
the equipment.
OpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 1
Proprietary and Confidential

Canada, ISED compliance
Compliance Statement Canada Déclaration de Conformité
This device complies with Innovation, Science
and Economic Development Canada (ISED)
license-exempt RSS standard(s). Operation is
subject to the following two conditions: (1) this
device may not cause interference, (2) this
device must accept any interference, including
interference that may cause undesired operation
of the device.
Under Innovation, Science and Economic
Development Canada (ISED) regulations, this
radio transmitter may only operate using an
antenna of a type and maximum (or lesser) gain
approved for the transmitter by Industry Canada.
To reduce potential radio interference to other
users, the antenna type and its gain should be so
chosen that the equivalent isotropically radiated
power (e.i.r.p.) is not more than that necessary
for successful communication.
Le présent appareil est conforme aux CNR
d'Industrie Canada applicables aux appareils
radio exempts de licence. L'exploitation est
autorisée aux deux conditions suivantes: (1)
l'appareil ne doit pas produire de brouillage, (2)
l'utilisateur de l'appareil doit accepter tout
brouillage radioélectrique subi, même si le
brouillage est susceptible d'en compromettre le
fonctionnement.
Conformément à la réglementation d'Industrie
Canada, le présent émetteur radio peut
fonctionner avec une antenne d'un type et d'un
gain maximal (ou inférieur) approuvé pour
l'émetteur par Industrie Canada. Dans le but de
réduire les risques de brouillage radioélectrique à
l'intention des autres utilisateurs, il faut choisir le
type d'antenne et son gain de sorte que la
puissance isotrope rayonnée équivalente (p.i.r.e.)
ne dépasse pas l'intensité nécessaire à
l'établissement d'une communication
satisfaisante.
RF Exposure (FCC/ISED)
This equipment complies with radiation exposure
limits set forth for an uncontrolled environment.
This equipment should be installed and operated
with minimum distance 20 cm between the
radiator and your body. This transmitter must not
be co-located or operating in conjunction with
any other antenna or transmitter.
Cet équipement est conforme aux limites
d'exposition aux radiations dans un
environnement non contrôlé. Cet équipement do
it être installé et utilisé à distance minimum de 20
cm entre le radiateur et votre corps. Cet émetteur
ne doit pas être co-localisées ou opérant en
conjonction avec tout autre antenne ou
transmetteur.
Electromagnetic compatibility
Caution: Use only approved accessories with this equipment. All cables must be
high quality, shielded, and correctly terminated. Unapproved modifications or
operation beyond or in conflict with these use instructions may void the authority's
authorization to operate the equipment.
Important Safety and Compliance Information
OpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 2
Proprietary and Confidential

Telemetering equipment classification
Warning:
• Telemetering equipment for use in Cl I, Div. 1, Gp. D Hazardous Location, for
hazardous locations.
• Temperature code: T1
• Ambient temperature: -40°C < Ta < 70°C.
Intrinsic safety
Warning: Substitution of components may impair intrinsic safety.
Lithium battery
Warning: Follow these procedures to avoid injury to yourself or others.
• The lithium battery may cause a fire or chemical burn if it is not disposed of
properly.
• Do not recharge, disassemble, heat above 100°C Celsius (212°Fahrenheit),
crush, expose to water, or incinerate the lithium battery. Fire, explosion, and
severe burn hazard.
• The battery used in this device may present a risk of fire or chemical burn if
mistreated.
• Keep the lithium battery away from children.
• Batteries must not be replaced or modified in any way.
Transportation classification
The Federal Aviation Administration prohibits operating transmitters and receivers on all
commercial aircraft. When powered, the Itron device is considered an operating transmitter
and receiver and cannot be shipped by air. All product returns must be shipped by ground
transportation.
Modifications, repairs, installation, and removal
To ensure system performance, this device and antenna shall not be changed or modified
without the express approval of Itron. Any unauthorized modification will void the user's
authority to operate the equipment.
In the event of malfunction, all repairs should be performed by Itron. It is the responsibility of
users requiring service to report the need for service to Itron.
Important Safety and Compliance Information
OpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 3
Proprietary and Confidential

Aluminum enclosure
Warning: This enclosure contains aluminum. Take care to avoid ignition hazard due
to impact.
Electrostatic discharge
Warning: Internal circuit components can be sensitive to electrostatic discharge.
Before installation, discharge electrostatic buildup by touching a metal pipe or other
earth-grounded metal object prior to touching the meter body, register housing, or
Itron device.
Electrostatic ignition hazard
Warning: Verify the area is not hazardous when installing, servicing, cleaning, or
touching the Itron device.
Device cleaning
Warning: Clean only with a damp cloth.
Do Not Drop
Warning: While Itron modules are designed to withstand a drop, dropping the
module may damage the device and void the warranty.
Important Safety and Compliance Information
OpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 4
Proprietary and Confidential

Product notification
Warning: These instructions are suggested when Itron-approved utility or installer
company-established valve installation procedures and practices are not available.
• Itron does not endorse or warrant the completeness or accuracy of any third-party
valve installation procedures or practices, unless otherwise provided in writing by
Itron.
• Follow your company's standard operating procedures regarding the use of
personal protection equipment (PPE).
• Adhere to guidelines issued by your company in addition to those given in this
document when installing or repairing valves.
• This product, as of the date of manufacture, is designed and tested to conform to
all governmental and industry safety standards as they may apply to the
manufacturer.
• The purchaser and user of this product must comply with all fire control, building
codes, and other safety regulations governing the application, installation,
operation, and general use of this valve to avoid leaking gas hazards resulting
from improper installation, startup, or use of this product.
• To ensure safe and efficient operation of this product, Itron strongly recommends
installation by a qualified professional.
Important Safety and Compliance Information
OpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 5
Proprietary and Confidential

Chapter 2 OpenWay Riva Gas Remote
Disconnect Installation Guide Overview
This installation guide provides instructions for physically installing, commissioning,
connecting, decommissioning, and physically disconnecting the OpenWay Riva Gas
Remote Disconnect remote-controlled valve.
Audience
This installation guide is intended for Itron personnel, third-party OpenWay Riva system
installers, and end-users of the OpenWay Riva Gas Remote Disconnect remotely-controlled
valve.
OpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 6
Proprietary and Confidential
Autres manuels pour OpenWay Riva
9
Table des matières
Autres manuels ITRON Télécommande
Manuels Télécommande populaires d'autres marques

Panasonic
Panasonic EUR7622KB0 Manuel utilisateur

Bang & Olufsen
Bang & Olufsen Beo4 Manuel utilisateur

Sunwave Tech.
Sunwave Tech. RemoteComm SRC-7000 Manuel utilisateur

Multiplex
Multiplex PROFI TX 9 Manuel utilisateur

One Remote
One Remote RMB4 Manuel utilisateur

FUTABA
FUTABA 9ZAP - PART2 Manuel utilisateur