Thanks for using ITC Voice Evacuation& Public Address System.
For better operation, please read this manual carefully before operating the system.

2
Notification
WARNING
To ensure the reliability of the equipment and the safety of personnel, please observe the following
when installing, using and maintaining:
● If any of the following conditions are found, please immediately turn off the power, plug out and
quickly contact your nearest dealer. Do not continue using this unit, which may cause a fire or
electric shock.
● If you find smoke or have a strange taste from the machine.
● If water or metal falls into the machine.
● If the unit is dropped or the case is damaged.
● If the wire is damaged (wire core exposure, broken wire, etc.).
● If the machine contains high-pressure parts, in order to avoid the fire or electric shock, absolutely
don’t open the case, if any questions please inform your nearest dealer.
● Do not place cups, bowls, vases or metal and other water-filled substances on the unit. Serious
spilled liquid may cause a fire or electric shock.
● Never expose the unit to rain and any moisture or water, which may cause electric shock or fire.
● Do not place metal objects or flammable materials from the vents on the machine cover, nor place
coins, which may cause fire or electric shock.
● Do not place heavy objects on the unit to avoid personal injury or property damage when the unit
is slipping.
● Make sure that the volume is turned on at the beginning of the boot, and the high volume of the
boot may cause hearing problems.
● Make sure that the volume is turned on at the beginning of the boot, and the high volume of the
boot may cause hearing problems.
● For long-term accumulation of dust to be cleaned, please inform your dealer to regularly clean the
machine, so as to avoid damage to the machine or cause a fire.
● The battery must be replaced with the same type of product and the correct installation should be
made in order to avoid electrical damage and explosion hazard.
● The product is a Class I device. The device must be well connected to ground. The power plug
must be connected to a power outlet with a grounding device to ensure that the equipment is fully
grounded.
● This product uses a power plug or appliance input socket as a disconnecting device with the power
supply, and must be disconnected if necessary for safety reasons.

3
● This equipment is only suitable for safe use at altitudes under 2000 meters.
Precautions
1. The installation environment
When installing the unit, in order to ensure the normal cooling of the host, should avoid the poor
ventilation of the place or high temperature environment, to avoid direct sunlight.
Recommend to install cabinet or other well-ventilated place indoor. If you use the machine in
the outdoors, please pay attention to waterproof, moisture, lightning protection measures.
Avoid installing in a violent place of vibration; do not place other equipment on the machine.
Working temperature : +5℃~ 40℃.
Humidity is limited to 5% to 90% (non-condensing).
2. To avoid electric shock and fire
Do not touch the hands and the source with wet hands
Do not spill liquid on the machine, so as to avoid short-circuit or fire inside the machine.
Do not place other equipment directly on the top of the unit.
Non-professional service personnel Do not disassemble the unit yourself to avoid damage and
electric shock.
3. Transport and handling
The packaging of the machine is designed and tested to ensure that the host will not be
accidentally damaged during transport. It is best to use the original packaging when handling the unit.
Do not move the host device between the place or cold or over hot to avoid condensation inside the
machine, affecting equipment life.
4. Please follow the warning instructions on this product, the warning signs on behalf of:
Applicable to 2000 meters above sea level and below safe use
Safe use only in non-tropical climates

4
5. Agreement
Please strictly follow the instructions in this manual. The software, hardware and appearance of
this product will be upgraded and updated continually. The above changes will be made without
notice.
Non-professional maintenance personnel, do not remove the product, to avoid damage and
electric shock.

5
C
on
te
n
t
s
1 Product picture.................................................................................................................................. 6
1.1 Product picture.......................................................................................................................... 6
2Introduction to features.................................................................................................................... 7
2.1 VA-6200RM Features............................................................................................................... 7
2.2 Main technical parameters........................................................................................................ 8
3Panel function instruction...............................................................................................................10
3.1 Front panel function instruction.............................................................................................. 10
3.2 Rear panel function description...............................................................................................12
4Instructions.......................................................................................................................................13
5Online upgrade instructions........................................................................................................... 14
Accessories: DIP switch table.............................................................................................................. 15

6
1 Product picture
1.1 Product picture
Figure 1- 1 VA-6200RM Product picture

7
2Introduction to features
2.1 VA-6200RM Features
Support 160 zones, 16 groups paging
Support configuring any zone to any group
Support paging to any zone of any controller.
Supports mix output / microphone priority output and adjustable output volume.
Support device paging priority configuring.
Support real-time display of zone status
Support 24 DC power supply, POE power supply;
Support online upgrade
Supports max 32 remote microphones

8
2.2 Main technical parameters
Electrical indicators
①Power supply
24V DC power supply
24V power supply through network interface
Performance
①Analog audio
MIC. input
Sensitivity 10MV ± 1mV
Frequency 200Hz ~ 10kHz
Input impedance 1kΩ
LINE unbalanced line audio input
Sensitivity 775MV ± 50mV
Frequency 80Hz ~ 16kHz
Impedance 10kΩ
Balance line output
Range 1000MV ± 50mV
Distortion <0.3%, 1kHz
Frequency 80Hz ~ 16kHz
Output impedance 470Ω
SNR > 60dB
②Communication
CAN interface
Remote MIC console CAN interface
Baud rate 100Kbps
Supports max.32 remote MIC consoles

9
③Mechanical indicators
Size (L × W × H) mm
Net weight Around 1.1 Kg
Installation Desktop or 19-inch cabinet
Color Black
④Environmental requirements
Operating temperature +5 ℃~ +40 ℃
Storage temperature -20 ℃~ +70 ℃
Relative temperature <95%

10
3Panel function instruction
3.1 Front panel function instruction
Front panel design sketch of VA-6200RM
1. Panel indicator light
①Power indicator(DC POWER)
Green: Normal input voltage
Light is out: Unusual input voltage
②Zone grouping status indicator (Z/G)
Green light normally on: Zone/Group output normally
Green light flashing: Zone/Group in selected status
Red light normally on: Zone in emergency/evacuation status.
Yellow light flashing: Zone in short-circuit status.
Yellow light normally on: Zone in open-circuit status
Light is out: No output from Zone/Group
③Zone/Group selected mode indication(ZONE/GROUP)
Green light normally on: Zone mode