Istore 180L Manuel utilisateur

INSTALLATION MANUAL 180L / 270L
istore.net.au
iStore - Installation Manual - Aug 2023

iStore - Installation Manual - Aug 2023
2
Important Information
• This manual includes all the necessary information regarding the installation and
maintenance of this product. Please take the time to read it through before operating.
• When installing the hot water cylinder, please follow the instructions as documented in
this manual.
• Once the installation is complete, check that all connections are secure and the unit is
full before the power is turned On.
• The Installer is to explain to the end user how to operate and maintain the unit in
accordance to this Installation Manual.
• iStore will not be held responsible for any damages or injuries caused by the incorrect
installation of this hot water system.
• It is important that the installation and operational instructions laid out in this manual
are strictly adhered to.
• A maintenance programme must be carried out as recommended in this manual.
Failure to comply with these recommendations will void the warranty.
• This manual could be subject to change without prior notice, if it is felt that product
improvements are to be carried out.

iStore - Installation Manual - Aug 2023
3
Content
1. Safety Precautions p4
2. Specications p7
2.1) Dimensions 270L p7
2.2) Dimensions 180L p8
2.3) Performance parameters p9
3. Safety Features p10
4. Installation
4.1) Installation Diagram p12
4.2) Transportation p13
4.3) Installation Space p14
4.4) Multi-System Conguration p16
5. Intelligent Operation Modes p17
5. Functionality p18
5.1) Function of the LED Display p18
5.2) Temperature Settings p22
5.3) Setting the Timer p23
5.4) Setting the Timer p24
5.5) Setting the Timer p25
5.6) Timer Settings Summary p26
5.7) Cancelling the timer p28
6. Maintenance and repair p31
6.1) Typical Failure and Solutions p31
7. Troubleshooting p33

iStore - Installation Manual - Aug 2023
4
Safety Precautions
To prevent personal injury and avoid causing damage to the unit, please take the time to
read the information documented in this manual.
ICON DESCRIPTION
A wrong operation may lead to serious injury or death
A wrong operation may lead to injury or loss of material
Prohibited (Next to this icon)
Compulsory - The listed action shall be followed
Please pay attention to what is indicated
The iStore shall be installed in strict accordance with local wiring regulations
and equipped with a power supply containing a ground/earth conductor.
The iStore is not intended for use by children, or persons with reduced physical
sensory or mental capabilities, lacking relevant skill or experience, without
suitable supervision.
The iStore must be installed by a licensed trade person and in accordance with:
• This Installation manual
• AS/NZS 3500.4 - “National Plumbing and Drainage Code Hot Water Supply
Systems-Acceptable Solutions“
• AS/NZS 3000 - Wiring Rules
• Local authority regulations
• BCA - Building Codes of Australia
• All local Occupational Health and Safety (OH&S) Regulations
Before installation, check the unit for any damage
Please ensure that the unit and power connections have a good earth. Failure
to do this may cause an electrical shock
Do not drill any holes or screws into the outer casing. Drilling of any holes will
void the warranty
WARNING
ATTENTION
INSTALLATION WARNING

iStore - Installation Manual - Aug 2023
5
The unit CANNOT be installed near ammable gas
Ensure that the position of the unit is level and in accordance with
AS/NZ 3500.4
In accordance with AS/NZS 3000 Wiring Rules this unit requires an
appropriately sized circuit and protection to meet the demand of
the chosen size unit. Refer to the Rated Current Input in section 2.3
page 9 and/or the tank label.
Do not put ngers or any other objects into the fans. Children
should be kept clear of this appliance
In the event the iStore has a major malfunction, please shut the
power o and contact your iStore Installer or iStore directly
If the iStore needs to be relocated or installed again, only use an
authorised dealer or qualied persons
It is prohibited for the end user to repair the unit themselves,
unless qualied. Failure to do so may lead to serious injury or, and
damage to the unit
Should the iStore need to be repaired, only use an authorised
dealer or qualied persons
Under no circumstances should water be sprayed directly into the
unit when cleaning. Only external surfaces to be cleaned with a
soft rag by non-qualied persons.
DANGER - High Temperature
INSTALLATION WARNING
RELOCATION OR REPAIR
CLEANING WARNING
Functionality WARNING
Safety Precautions
Unit Location
Unit Placement
Electrical
Connection
Shut O Power
Safety Warning
Important
Important
Shut O Power
Prohibited

iStore - Installation Manual - Aug 2023
6
Electrical Connection:
The installation of the iStore must strictly follow the AS/NZS 3000 wiring rules and local wiring
regulations, ensuring that a licensed electrician deems the circuit suitable. Adequate overload
protection and a residual current device of appropriate size should be installed. Opeak and
controlled load circuits are acceptable as long as there is a manual override option for maintenance
and support during business hours.
500kPa Pressure Reduction Valve:
Pressure Reduction Valve (PRV 500) - A pressure reduction valve of 500kPa maximum must be tted
immediately downstream of the cold water non-return isolation valve. Failure to install a pressure
reduction valve will void the warranty. Please note cold water supply line to the tempering valve must
be run after the PRV to ensure equal supply pressure to the tempering valve. This valve is not required
shall a 500kPa PRV be installed at the water main supply to the property.
Note: In SA, WA & QLD (and some other areas of other states subject to local authority regulations) it is a requirement that
an expansion control valve be tted between the non-return isolating valve and the water heater.
iStore Basics
How it works
1. A fan draws in air, containing heat energy,
across the evaporator.
2. The evaporator turns the liquid refrigerant
into a gas.
3. The compressor pressurises the refrigerant
into a hot gas.
4. The hot gas inside the condenser coil heats
the water inside the coil-wrapped tank.
5. The refrigerant reverts back to a liquid after
heating the water and continues to the
evaporator for the process to start again.
6. The cycle continues until the set target
temperature is achieved.
As water is used in the home, the cycle will
restart once the temperature in the
lower section of the tank has dropped
11 degrees below the target temperature.
1
2
3
4
6
5

iStore - Installation Manual - Aug 2023
7
Specifications
2.1 Dimensions 270L
Dimensions
Height (mm) 1955
Diameter (mm) 640
Height to water inlet (mm) 99
Height to water outlet (mm) 1194
Hot water condensation (mm)
Height to PTR Valve (mm)
Height to Anode 1094
Net weight (Kg) 130
1955
1194
1194
1094
640
99
Unit: mm
HW outlet
HW condensation PTR Valve
Anode
Cold water inlet
Overall height
Overall width
270L iStore
Top View
685

iStore - Installation Manual - Aug 2023
8
Specifications
2.2 Dimensions 180L
Dimensions
Height (mm) 1957
Diameter (mm) 540
Height to water inlet (mm) 60
Height to water outlet (mm) 1240
Hot water condensation (mm)
Height to PTR Valve (mm)
Height to Anode 1140
Net weight (Kg) 93
1956
1240
1240
1140
540
60
Unit: mm
HW outlet
HW condensation PTR Valve
Anode
Cold water inlet
Overall height
Overall width
180L iStore
Top View 583

iStore - Installation Manual - Aug 2023
9
Specifications
2.3 Performance Parameters
• Operating water pressure 0.15 to 0.7MPa
• Ambient temperature is -5~43o C (compressor)
• The max temperature of water tank is 75o C
• Maximum inlet water pressure is 500kPa
• PTR Valve setting is 850kPa
• ECV Valve setting is 700kPa (if required)
Value 180L 270L
Heating capacity kW 1.7 3.6
Water tank capacity L180 270
Compressor power input kW 0.43 0.94
Compressor running current A 1.8 3.9
Power supply V 240 240
Compressor number Quantity 1 1
Compressor Type Rotary Rotary
Rated outlet water Temp. C 60 60
Air volume m3/h 700 450
Noise dB(A) 45 @1m 48 @ 1m
Water inlet/outlet size inch 3/4 3/4
Auxilary e-heater kW 1.5 1.5
Rated Power Input kW 2.2 3.1
Rated Current Input A 9.2 13
Hot and Cold Water Connections
All plumbing connections must be performed by a licensed plumber in accordance with local authority regulations.
The cold water inlet connection to the storage tank is 3/4 FI. All pipes and valves must be insulated as per the current AS/NZ 3500.4 Section
8.2. The cold water inlet requires the following valve train please refer to system diagram page for correct installation.
• Approved isolating/non return valve
• 500 kPa Pressure Reduction Valve (PRV) valve
• 700 kPa Expansion Control Valve (ECV)
The maximum inlet water pressure rating is 750kPa. Cold water supply pressures exceeding 500kPa a 500kPa Pressure Reduction valve
shall be installed immediately downstream from the Duo valve.
The hot water outlet from the tank is ¾ inch FI. All hot water pipes must be insulated by UV stable & appropriately rated insulation.
Working Range

iStore - Installation Manual - Aug 2023
10
Safety Features
To prevent unwanted changes to your iStore settings. The Smart Screen will automatically lock after 3 minutes.
If the unit stops and you restart the unit or turn it on by the manual switch, the unit will not start to run again for
approx. 3 minutes. This is a protection feature to safeguard the compressor.
In the heating mode the unit will defrost automatically, maximizing the heating eciency
(Lasting 2 - 10 minutes). The fan motor will stop running whilst the unit is defrosting.
In order to use the unit correctly, please operate the unit at ambient temperature of -7º ~ 50º Celsius.
If the water temperature reaches 85º C, the power of unit will be cut o (refer to manual to reset).
An 850kPa, 10kW and 99°C PTR valve is used on the iStore water tank, which is located on the side of the
water tank and is essential for its safe operation. The PTR valve is designed to allow 3-5% of total tank volume
to discharge during heating to allow for hot water expansion. Water may drip from the discharge pipe of the
pressure-relief valve. The discharge pipe must be left open to the atmosphere under all circumstances. PTR
Valve the discharge pipe shall be installed downwards and with discharge pipes in a frost free environment.
Refer page 12 for how to connect. Seal the thread with approved sealant such as Teon tape and screw the
valve into the correct opening and leave the valve outlet pointing downwards. The discharge pipe diameter is
permitted to be run in 15mm copper providing the length of discharge pipe does not exceed 9m.
During normal operation, condensation occurs from the transfer of air across across the evaporator coil. This
process is drawing humidity from the air and creates condensation/water droplets on the coils, which in turn is
captured in the fully moulded condensate tray and discharged through the condensate drain line. In locations
with humidity greater than 80%, up-to 5 litres per day can be expected under normal operating conditions.
Smart Screen Lock
Start up delay protection
Defrost mode
Working conditions
Thermal cut-o saftey device
Condensation
Pressure Temperature Relief Valve (PTR)
DANGER: Failure to operate the relief valve easing gear at least once every six months may result in the water
heater exploding. Continuous leakage of water from the valve may indicate a problem with the water heater.
Autres manuels pour 180L
1
Ce manuel convient aux modèles suivants
1
Table des matières
Manuels Pompe à chaleur populaires d'autres marques

Mitsubishi Electric
Mitsubishi Electric PUZ-SWM60VAA Manuel utilisateur

Dimplex
Dimplex LI 16I-TUR Guide de l'utilisateur

Carrier
Carrier WSHP Open v3 Guide de configuration rapide

TGM
TGM CTV14CN018A Manuel utilisateur

Carrier
Carrier 38MGQ Series Manuel utilisateur

Kokido
Kokido K2O K880BX/EU Guide de dépannage