iSiTech HEALTHGUARD TECHNOLOGY HGTHRMSEC Manuel utilisateur

Quick Start Guide
Version: 1.0
Thermal Security Camera
Model No. HGTHRMSEC

2
Thermal Security Camera
Contents
Thermal Security Camera Introduction.................................................................................................3
System Description ...........................................................................................................................3
Installation ............................................................................................................................................4
Installation Environment...................................................................................................................4
Installation Tips .................................................................................................................................4
Camera Connection...............................................................................................................................5
Cable Connections.............................................................................................................................5
Getting Started......................................................................................................................................6
Thermal Security Camera Software Installation .................................................................................10
Main Screen ....................................................................................................................................11
Settings............................................................................................................................................13
Default Settings...............................................................................................................................14
Biometric Identification ..................................................................................................................15
Specifications ......................................................................................................................................16
Technical Support ...............................................................................................................................18

3
Thermal Security Camera
Thermal Security Camera Introduction
Model No. HGTHRMSEC
The HealthGuard Technology Thermal Security Camera is designed to monitor high
traffic areas such as airports, public transport terminals, customs ports, hospitals,
schools, enterprises, markets, and shopping malls.
System Description
The system combines a binocular temperature detecting camera with intelligent
biometric scanning. The unit is easy to install and accommodates fast screening of
up to 30 individuals at one time. Intended for monitoring lobbies, gates, entrances
and exits, the system employs thermal image signal processing (ISP) technology
adaptive to AGC, DDE, 3D and DNR data and video communications protocols.
•Subject acquisition distance is 1-10 feet
•Temperature accuracy is +/- 0.6° at 2-4 feet
•Audible notification alert sounds at presence of each new person
•Audible and screen alert sounds if high temperature is detected
•Live streaming capability
•Data may be saved or transferred to hard drive
•Video may be saved to hard drive
•Can be wall, ceiling, or doorway mounted

4
Thermal Security Camera
Installation
Installation Environment
IMPORTANT: Thermal imaging cameras are not intended for outdoor use. Install the
camera so that it is protected from direct sunlight, wind, HVAC systems and electronic
interference.
•Select a location with even lighting and consistent temperatures (5°F - 302°F).
•Avoid backlighting, such as installing the camera facing a window or doorway
that lets in bright light.
•Avoid strong reflected light.
•Avoid shadows.
•If necessary, install additional lighting to achieve an intensity of 250~800 Lux).
Installation Tips
•Before permanently mounting the camera, test for optimum capture distance
and adequate lighting.
•For best image results, install the camera at a height of approximately 6.5 ft.
above the target area.
•For accurate body temperature detection, the camera to target distance should
be within 3.3 to 6.5 ft.
•Adjust camera so that it points downward at a 0 to approximately 15°angle.

5
Thermal Security Camera
Camera Connection
1. Connect the Thermal Security Camera to a computer or your server using the
RJ45 LAN cable(4).
2. Connect the power cable (2).
3. The device will power up immediately.
Cable Connections
Cable No. Interface Type
1 Audio Audio Input/Output (grounded)
2
Power
12VDC
3
Relay
+
:
NO Normally Open Port
-
:
COM Public Port
4 LAN RJ45 Network Interface
4
1
2
3

6
Thermal Security Camera
Getting Started
In Windows Settings, go to the Network and Internet Sharing Center.
Select Ethernet connection.

7
Thermal Security Camera
Click on Properties.
Select the TCP/IP configuration shown below and click OK.

8
Thermal Security Camera
Select automatic IP assignment.
You also may access the IP wizard to search IP addresses.
Select the camera’s IP address.
The default IP address is: 192.168.1.18

9
Thermal Security Camera
You can modify the IP address by using the search tool, if necessary.
Enter the Subnet Mask: 255.255.255
Enter Default Gateway: 192.168.1.1
Click OK.

10
Thermal Security Camera
Thermal Security Camera Software Installation
After the device is powered on and connected to your computer, download the
software and the user manual.
In your browser, type the following address or click the hyperlink:
HealthGuardtech.com/temperature-camera
Click the Software button under the product photo.
Click the Download Our Software button.
Download and open this file:
AI-Thermal-Camera_V1.0.50.HH - 0717.zip
Table des matières