Iron logic Z-5R WEB mini Manuel utilisateur

1
1. GENERAL INFORMATION
Controller Z-5R WEB mini is intended for use in access control systems
(ACS) and provides control of a single access (pass) point.
Controller operation management (changing the operating modes and key database) is
possible in the standalone mode using master keys or via an integrated web interface, as well as
using an external controlling software in the so-called network mode. Additionally, in network
mode, it is possible for the controlling software to receive the controller event log.
In both modes, the controller makes the decision to allow access independently based on the
internal key database and the current mode of operation regardless of the existence of a
connection with the controlling software. To operate in the network mode or with the integrated
web interface, the controller must be connected to the Wi-Fi network.
In the configuration mode, the controller itself becomes an access point providing the means of
communication with it to connect it to an existing Wi-Fi network and configure other parameters.
Access through the pass point is carried out based on checking the status of the presented
identifiers (proximity cards, Touch Memory keys or pin codes), which will be hereinafter referred to
as keys.
By their functional purpose, the controller distinguishes between keys intended for passes and
keys intended for programming the controller.
Pass keys can be common and blocking. Blocking keys have a higher status.
In normal mode, the controller "allows" to pass using both common and blocking keys.
In the "Lock" mode, the passage through the blocking keys is allowed but the passage through
the common keys is closed (for example, when issuing common keys to employees and blocking
keys to security officers,
it is possible to provide passage to all categories of employees during working hours in normal
mode, but only security officers will be allowed to pass at night in the lock mode).
The keys for programming the controller are called master keys. They are designed only for
programming the controller without a computer and not intended for passage. Master keys
allow you to: add/remove common, blocking and master keys, set the time of sending the opening
signal to the locking device (access permissions), enable/disable the "Accept" pass mode.
In the "Accept" mode, any key is perceived as resolved and written into the controller memory
as a common key for passing. The mode is used to generate a key database when installing ACS
at the site when the keys for passage have already been issued. Then, being for some time in the
"Accept" mode, the controller "collects" information about the presented keys and after enabling
the normal mode, the passage will be carried out only through the keys written into its memory.
To obtain key codes, the controller supports the connection of 2 readers (for the entrance and
the exit) via the Wiegand (26, 34, 42, 50) or iButton (Dallas Touch Memory) protocols. After
checking the access rights, the controller issues a control signal (on/off the power transistor) to the
locking device (electromechanical lock, electromagnetic lock or latch, turnstile). The type of shut-
off device and the protocol for connecting the readers are selected in the controller configuration
mode.
Z-5R WEB mini www.ironlogic.me
Controller Z-5R WEB mini
User Manual

2
The controller allows 2048 events to be stored in a cyclic buffer (receiving the code, triggering
the door sensor, issuing a control signal, etc.).
To increase the functionality of the operation, the controller allows to:
• connect a door sensor - to record the event "the passage occurred" and reduce the time
the sound alarm is active and inform about the unlocked door (reduce the time of sending
the "opening signal" to the locking device);
• connect the "exit button" to open the door without checking access rights;
• receive a signal by the controller from an external source for emergency door unlocking.
Wi-Fi communication module
Standards: IEEE 802.11 b/g
Frequency range: 2.4-2.4835 GHz
Transfer rate 11g: up to 54 Mbit/s
11b: up to 11 Mbit/s
Wireless signal strength: <20dBm (<100mW)
Operation mode: Access point, client
Wireless network security: WPA/WPA2, WPA-
PSK/WPA2-PSK
USB Interface
Connector: USB Type micro A
Version: USB 2.0
Mode: Device, Full/Low Speed
Other parameters
Light and sound indication of operation
modes:
Yes
DC power supply voltage, V: 12 (9–24 allowed)
Maximum current consumption at 12 V, mA: 100
Incorrect power-on protection: Yes
Dimensions, mm: 64х64х19
Weight, kg, not more than: 150
Controller
Key memory, pcs. 2024
Event memory, pcs. 2048
Number of connected readers
(contactors), not more than:
2
Connection protocols:
contactor readers
iButton, Wiegand
iButton
Reader indication control: yes
Output for lock connection: MOS transistor
Power output current, А:5
Jumper to select the lock type: electromagnetic
electromechanical
Lock opening duration setting, sec: 0.1 to 6,500
(factory value - 3)
2. TECHNICAL SPECIFICATIONS
Z-5R WEB mini www.ironlogic.me

3
3. CONNECTING EXTERNAL DEVICES
The figure shows the overall dimensions and terminal layout on the board of the device:
THE PURPOSE OF THE TERMINALS IS SHOWN IN THE TABLE
Fig.1 Overall dimensions and terminal layout.
ZUMM For connecting an external buzzer. It is necessary to use a buzzer with a built-in
generator for a voltage of 12 volts and a consumed current of not more than 200
mA. The positive pin should be connected to the terminal + 12V, and the negative
pin should be connected to this terminal.
TM External reader or contactor, in Wiegand mode: DATA0 signal.
GND Signal ground. To connect the common wires of the external reader,
contactor, door position sensor and door opening button.
EXIT Door opening button. Internal reader or contactor
can be connected simultaneously. In Wiegand mode: DATA1 signal.
LED Control of the green LED of the external reader.
LOCK Terminal for connecting the negative wire of the lock winding.
+12V +12 Volt.
Connection of the positive pin of the power supply and the positive lock winding wire.
GND Power ground. Connection of the negative pin of the power supply.
DOOR Connection of the door position sensor. Twisted pair is recommended. When the
door is opened, the triggered sensor allows turning off the sound on the controller
prematurely, as well as saving energy by turning off the electromechanical lock
immediately after opening the door or turning on the electromagnetic lock only when
the door is already closed.
CFG
CLR
CR2032
iron iL Logic
DOOR
+12V
LOCK
EXIT
GND
ZUMM
ADD
GND
TM
LED
Z-5R WEB mini
58
58
64
19
64
Z-5R WEB mini www.ironlogic.me

4
Fig. 3 Connection diagram for external devices.
Entrance ТМ
Reader entrance and exit
IN. READ
Optional connection:
- External buzzer
- External LED (SDI)
- Door opening button
- Door position sensor
Fig.4 Connection of external readers via iButton protocol.
GND TM
EXIT
LED
LOCK
+12V
GND
DOOR
ZUMM
DATA 0
+12V
GND
GND TM
EXIT
LED
LOCK
+12V
GND
DOOR
ZUMM
DATA 0
+12V
GND
Exit
Entrance
Exit
button
Reader 2
Reader 1
Z-5R WEB mini
Z-5R WEB mini
Power
supply
Reader
MATRIX-II
Reader
MATRIX-II
Entrance Exit
Sensor
Lock
Door
opening
button
Controller
Z-5R WEB mini
12V
CFG
CLR
CR2032
iron iL Logic
DOOR
+12V
LOCK
EXIT
GND
ZUMM
ADD
GND
TM
LED
Z-5R WEB mini
Fig. 2 Connection diagram for Z-5R WEB mini.
Entrance ТМ
External buzzer
Lock
Button
External buzzer
Ground (-)
Door opening
button
External SDI (+)
Lock
+ 12 V
Ground (-)
Door sensor
Door sensor
PS 12V
Z-5R WEB mini www.ironlogic.me

5
4. DEVICE NETWORK CONNECTION METHODS Z-5R WEB mini
When using the device in network mode, you'll need to adjust your Wi-Fi network connection
settings. It should be noted that by its functions, the Z-5R WEB mini device consists of two units:
the ACS controller itself and the module for communication with the local computer network via
the Wi-Fi protocol.
The communication module provides connection of the device to the local network available at
the site via the Wi-Fi interface and establishes the connection with the computer with the ACS
control software is installed, which implements access control functions (map list downloading,
access right setting, event reading from the buffer, etc.).
According to the method of establishing a connection with the control software, three modes are
available:
-WEB communication mode. In this mode, the communication module connects to the
controlling web server on the Internet and the device is controlled via the website
(for example, "cloud" ACS - www.guardsaas.com);
Fig.5 Connection of external readers via Wiegand protocol.
+12V
GND TM
EXIT
LED
LOCK
GND
DOOR
ZUMM
+12V
GND
DATA 1
LED-G
LED-R
BEEP
DATA 0
TM
EXIT
LED
LOCK
GND
DOOR
ZUMM
+12V
GND
Entrance
Exit
button
Reader 1
Reader 2
+12V
GND
DATA 1
LED-G
LED-R
BEEP
DATA 0
EXIT
TM
Reader
DATA 1
DATA 0
Z-5R WiFi
EXIT
TM
Reader
DATA 1
DATA 0
Z-5R WEB mini
Z-5R WEB mini
Fig.6 Connection of contactors.
Entrance
and exit
contactors
CFG
CLR
CR2032
iron iL Logic
DOOR
+12V
LOCK
EXIT
GND
ZUMM
ADD
GND
TM
LED
Z-5R WEB mini
Z-5R WiFi
Z-5R WEB mini www.ironlogic.me

6
- Server communication mode. In this mode, the communication module listens for a connection
using the TCP/IP protocol from the computer with the control software installed (for example,
GuardLight, GuardCommander, Avangard);
- Client communication mode. In this mode, the communication module tries to establish a
connection on its own via the TCP/IP protocol with the control software. To configure this mode,
you need to specify the IP address and TCP port on the remote computer (for example, in
GuardLight or Avangard software);
Web server
DB
Wi-Fi
Internet
Wi-Fi
Z-5R WEB mini www.ironlogic.me

7
5. WEB INTERFACE
The web interface is used to configure communication parameters and connected equipment.
To perform the first configuration, you need a device that can connect to the network via Wi-Fi
(tablet, laptop or smartphone) and has an integrated Internet browser (Internet Explorer, Firefox,
Opera, Chrome, etc.).
To access the web interface of the device settings, you need to perform the following actions:
1. Set the jumper to CFG position (see P 6 "Turning on the device and getting started");
2. Turn on the power supply;
3. Connect your device to Wi-Fi:
- Wait for the appearance of a Wi-Fi network named Z-5R WiFi_XXXXXX;
- Connect to this network (connection password - AUTH_KEY);
The factory value AUTH_KEY of the eight-character is shown on the label located on the back
of the device case or at the end of this manual (case sensitive!).
4. Using a browser, open the page at http://192.168.10.1 (login: z5rwebmini, password
AUTH_KEY);
5. Scrolling through the menu pages, configure the settings (remember to press Save on each
page).
After the configuration is complete, you should remove the jumper from the CFG position, reboot
the controller and wait for the Z-5R WEB mini to connect to the local network. Now the web
interface will be available at the IP address that was assigned to the device during configuration
(will be described below in P 5.3) or received from the router (DHCP server) when registering in
the local network.
5.1 Language selection
At the first activation, English is set in the web interface. To select the Russian language, click on
the "Russian" in the upper right corner of the interface:
5.2 Status tab
The Status tab displays the current status of the device:
Z -5 R WEB mini
SN:46-000001
Status
Mode:
Connection:
Run time:
Controller software version
Communication module software version
CFG jumper
WEB
0 days 00:01:01
2.22
1.09
On
Z-5R WEB mini www.ironlogic.me

8
Here:
Network (SSID): A name of the Wi-Fi network to which the device will be connected.
Password: An encryption key (password) used on the above Wi-Fi network.
Search for networks: Activation of the search for currently available Wi-Fi networks. After
searching for available Wi-Fi networks will be finished, a list of found networks will appear with a
signal strength displayed:
To select a network, highlight the desired network and then press OK. Then the name of the
Wi-Fi network will automatically appear in the settings. If the network does not broadcast its
name, you must enter the network name manually in the Network (SSID) field. When using
encryption, you must enter the encryption key.
Mode: A device operating mode (WEB, Server, Client, Standalone).
Connection: In the Client and Server modes, it displays the IP address of the computer to
which the connection is established.
Run time: the duration of the device's operation from the moment of turning the power on.
Controller software version: Displays the current firmware version of the controller.
Communication module software version: Displays the current firmware version of the
communication module.
CFG jumper: displays the status of a jumper: On - installed, Off - removed.
5.3 Connection Settings tab
On the Connection Settings tab, the method and parameters for connecting the communication
module to the local network can be set. Setting the parameters is similar to setting up an
Internet router.
Connection Settings
Network (SSID) mySSID
WiFiPassword
192.168.1.129
255.255.255.0
192.168.1.1
Password
8.8.8.8
Use DHCP
Static IP
Subnet mask
Gateway
DNS server
Search for networks
Save
Network test
Wi-Fi
IP
Connection Settings
Available Wi-Fi networks
NET.111
ironlogic
default
-90 dBm
-76 dBm
-88 dBm
OK
Z-5R WEB mini www.ironlogic.me

9
Network test: Verification of connectivity with the current SSID and password values. However,
with the correct password, the router may refuse in connection because it can be configured to
check the MAC address of the device.
Use DHCP: Instructs to access a DHCP server to automatically
obtain the IP address and other network parameters necessary to operate on this local network.
If there is no DHCP server, you must correctly configure the following network settings:
Static IP: A unique IP address that provides the device's address on the local network.
Subnet mask: A subnet mask used on this local network.
Gateway: An IP address of the gateway to communicate with other networks (including the
Internet).
DNS server: An IP address of the DNS server.
For correct operation, all the specified parameters must be set. If you do not know some of the
parameters, please contact your system administrator.
When the configuration is complete, you must press Save.
5.4 Operating Mode tab
If Z-5R WEB mini is intended to operate in the network mode, i.e. controlled by external
software, then after configuring the connection to the local network, it is necessary to configure
the mode of establishing communication between the controlling software and the
communication module. On the Operating Mode tab, the desired method of connection to the
software when operating in the network mode can be selected:
Here:
Authentication key: An authentication key is required to connect to the cloud Internet server in
the WEB mode when operating through the server, as well as to access the web interface of the
Z-5R WEB mini device.
Initially, the factory value indicated on the label on the device casing is displayed here (see
AUTH_KEY). At this configuration stage, it can be changed, if necessary (numbers and Latin
letters are allowed).
Operating mode: Selection of the network mode of operation - WEB, Server, Client -
or selection of the Standalone mode of operation.
Operating mode
General settings
Authentication key DEADBEEF
Operating mode WEB
Z-5R WEB mini www.ironlogic.me

10
5.4.1 Web
The WEB mode provides a connection with the "cloud" service. To configure the WEB
operating mode, it is necessary to check with the service provider and set the following
parameters:
Server address: A name or IP address of the WEB server of the "cloud" service to which the
controller will connect.
Use HTTP proxy: Specifying the need to contact a special server on the network
to access the Internet.
Proxy server address: A network address of the proxy server on the local network.
Proxy server port: A port for connecting to the proxy server.
Password: A password to access the data on the WEB server.
Connection interval: An interval of connection to the WEB server in seconds.
Number of events: A number of events in the controllers when data is prematurely sent to the
WEB server before the transmission interval expires.
When all the parameters are configured, you must press Save.
5.4.2 Server
In this mode, the communication module awaits for the control software to connect to its opened
local port. If the server operating mode is selected, the following should be set:
Here:
Local port: A TCP port to which the control software will be trying to connect.
Allowed IP: An IP address of the computer from which the control software is allowed
to connect to the controller (255.255.255.255 to allow all IP addresses).
When all the parameters are configured, you must press Save.
5.4.3 Client
If the Client operation mode is selected, the communication module will regularly try to establish
a connection with the control software.
The following parameters should be set:
hw.guardsaas.com
192.168.10.1
3128
10
1
Server address:
ab974088d09d4dc3
Use HTTP proxy:
Proxy server address:
Proxy server port:
Password:
Connection interval:
Number of events:
WEB
Server
1000
Local port:
255.255.255.255
Allowed IP:
Client
192.168.1.10
25000
Server address:
Server port:
Z-5R WEB mini www.ironlogic.me
Table des matières
Autres manuels Iron logic Contrôleurs

Iron logic
Iron logic Z-5R Web Manuel utilisateur

Iron logic
Iron logic Z-5R NET Manuel utilisateur

Iron logic
Iron logic Matrix III NET Manuel utilisateur

Iron logic
Iron logic Z-5R Relay Wiegand Manuel utilisateur

Iron logic
Iron logic Matrix III 220 Manuel utilisateur

Iron logic
Iron logic Matrix II Wi-Fi Manuel utilisateur

















