PAGE 4
OBLICA | PHAROS INSTALLATION AND USER MANUAL
MINIMUM CLEARANCE – INTERNAL
2.1 Clearance from non-combustible surfaces
(eg masonry)
100mm minimum clearance is required from fully
non-combustible surfaces.
100
100
Non Combustible
Non Combustible
2.2 Clearance from glass
400mm minimum clearance is required from normal
non-combustible glass.
2.3 Clearance from combustible surfaces
(eg timber joist & concrete)
Clearances may be reduced with the application of
heat shielding to walls in accordance to the
Australian Building Code.
For information on heat shielding please contact our
IMPORTANT:
Frames must also be considered. Timber window
frames must be treated as combustible surfaces
(see 2.3). Aluminium frames can be treated as
non-combustible surfaces (see 2.2).
2. PRE-INSTALLATION (CONTINUED)
Glass (frameless or aluminium frame)
Glass (frameless or aluminium frame)
400mm
400mm
625mm
Combustible
Combustible
625mm
Combustible
Combustible
750mm
750mm
Configuration 1 – Parallel installation
Configuration 2 – Corner installation