INVERSilence Tech B+InverSilence15 Manuel utilisateur

INVERTER POOL PUMP
INSTALLATION & OPERATION MANUAL
Model: B+InverSilence15 / B+InverSilence22
This manual contains important informationthat will
help you in operating and maintaining this product.
Please read the manual carefully beforeinstallation &
operation and retain it for future reference.
Thank you for purchasing our inverter pool pumps.

CONTENTS
1. IMPORTANT SAFETY INSTRUCTIONS .............................................. 1
2. TECHNICAL SPECIFICATIONS .................................................................. 2
3. OVERALL DIMENSION ............................................................................... 2
4. INSTALLATION ............................................................................................ 2
5. SETTING & OPERATION ............................................................................ 4
6. WIRING CONNECTION .............................................................................. 6
7. EXTERNAL CONTROL(Digital input functionality was included) ............ 7
8. TROUBLE SHOOTING ................................................................................ 8
9. ERROR CODE ............................................................................................. 9
10. MAINTENANCE ....................................................................................... 10
11. WARRANTY & EXCLUSIONS .................................................................. 11
12. WEEE LEGISLATION ............................................................................... 11

1
1. IMPORTANT SAFETY INSTRUCTIONS
This guide provides installation and operation instructions for this pump. Consult your supplier
with any questions regarding this equipment.
1.1When installing and using this electrical equipment, basic safety precautions
should always be followed:
•RISK OF ELECTRICAL SHOCK. Connect only to a branch circuit protected by a ground-fault
circuit-interrupter (GFCI). Contact a qualified electrician if you cannot verify that the circuit is
protected by a GFCI.
•This pump is for use with permanent installed in ground or above ground swimming pools and
may also be used with hot tubs and spas if so marked. Do not use with above ground pools
that can be readily disassembled for storage.
• The pump is not submersible.
• Before servicing the pump; switch off power to the pump by disconnecting the main circuit to
the pump.
• Never open the inside of the drive motor enclosure.
1.2 All installations must be fitted with earth leakage or residual current protection
devices, having a rated residual operating current not exceeding 30mA.
WARNING:
• Do not run the pump dry. In case of dry run, mechanical seal will be damaged and the pump
will start leaking. Fill the pump with water before starting.
• Before servicing the pump, switch OFF power to the pump by disconnecting the main circuit
to the pump and release all pressure from pump and piping system.
• Never tighten or loosen screws while the pump is operating.
• Do not block the pump suction.

2
2. TECHNICAL SPECIFICATIONS
3. OVERALL DIMENSION
Model
Corresponding L length (mm)
B+InverSilence15
572
B+InverSilence22
585
Model
Advised pool
volume (m³)
P1
V/Ph/Hz
Backwash
Circulation (m³/h)
KW
Qmax(
m³/h)
Xmax(
m)
At 6m
At 8m
At 10m
B+InverSilence15
40~55
0.1~0.70
220~240/
1/50
27.5
19.1
12.9~18.6
8.1~15.3
8.7~11.1
B+InverSilence22
60~80
0.14~1.0
32
21
13.5~23.1
12.0~20.1
10.9~16.5

3
4. INSTALLATION
4.1. Pump Location
1) Locate pump as close to pool as practical and run suction lines as direct as possible to
reduce friction loss.
2) To avoid direct sunshine or heat, It is recommended to place pump indoor or in the shade.
3) DO NOT install pump in a damp or non-ventilated location. Keep pump and motor at least
150mm away from obstacles,Pump motors require free circulation of air for cooling.
4) The pump should be installed horizontally and fixed in the hole on the support with screws
to prevent unnecessary noise and vibration.
4.2. Piping
1) For improved pool plumbing, it is recommended to use a larger pipe size. When installing
the inlet and outlet fittings (male adaptor), use thread sealant.
2) Piping on the suction side of the pump should be the same or larger than the return line
diameter, to avoid pump sucking air, which will affectefficiency of pump.
3) Plumbing on the suction side of the pump should be as short as possible.
4) For most installationswe recommend installing a valve on both the pump suction and return
lines so that the pump can be isolated during routine maintenance. However, we also
recommend that a valve, elbow or tee installed in the suction line should be no closer to the
front of the pump than five times the suction line diameter.
5)Pump outlet piping system should be equipped with a check valve to prevent pump from the
impact of medium recirculation and pump-stopping water hammer.
4.3. Valves and Fittings
1) Do not install 90° elbows directly into pump inlet. Elbows should be no closer than 250mm
to the inlet. Joints must be tight. Suction line diameter must equal or be larger than the
discharge line diameter.
Return to pool 63mm
ELBOW
250mm
Suction 63mm

4
2) Flooded suction systems should have gate valves installed on suction and discharge pipes
for maintenance, however, the suction gate valve should be no closer than five times the suction
pipe diameter as described in this section.
3) Use a check valve in the discharge line when using this pump for any application where there
is significant height to the plumbing after the pump.
4) Be sure to install check valves when plumbing in parallel with another pump. This helps
prevent reverse rotation of the impeller and motor.
4.4 Check before initial startup
1) Check whether pump shaft rotates freely;
2) Check whether power supply voltage and frequency conform to the nameplate;
3) Facing fan blade, direction of motor rotation is clockwise;
4) It is forbidden to run pump without water.
5. SETTING & OPERATION
5.1 Interface
Manual Mode
Timer Mode
Backwash Mode
Description
On/off
Lock/Backwash:
When the screen is locked, press >3
seconds to unlock the screen;
When the screen is unlocked, press it
for backwash mode.
Up: Increase value(capacity& time)
Down: Decrease value(capacity& time)
Timer: Switching from manual to Timer
mode
Capacity:40~100%

5
5.2 Capacity Setting
Note: The inverter module can be operated manually or automatically at regular intervals.
The system automatically saves the 4 latest valid settings.
Key
Description
1
Press >3 seconds to unlock the screen;
Press <3 seconds for backwash mode;
Under backwash mode, pump will count down in 180s, use or to adjust
backwash time from 30-900s.
2
Press the button to start. The pump will run at full capacity (100%) .
3
Use or to adjust by 5% to a specific running capacity if needed.
5.3 Timer Setting
*Overlap setting of time will be considered as invalid, the pump will only run based on the
previous valid setting.
*During timer setting, if you want to return to the previous setting, hold for3 seconds.
1.Enter timer setting
2.Set current time
3. Move to next step
4.Decide the specific capacity
5.Repeat above steps to set other
3timers
6. Hold 3 seconds to save setting
7.Check 4 timers to make sure there
is no invalid setting
or

6
5.4 Parameter Setting
Under OFF mode, hold for 3 second to enter parameter settings.
Parameter
Description
Default Setting
Setting Range
1
Di2
100%
40%~100%, by 5% increments
2
Di3
80%
3
Di4
40%
6. WIRING CONNECTION
Warning:
All electrical wiring MUST conform with applicable National Electrical Safety Code
(NESC) and National Electric Code (NEC).
Please refer to the below schematic for information on how to correctly install your
pump.

7
7. EXTERNAL CONTROL
(
Digital input functionality was included
)
External control can be enabled via following contacts. Pressing on/off can stop the pump even
if working via an external controller.
Threephase pump
AC power input
Power Source
220~240VAC,1Ph,
50/60Hz
Breaker
(Customer prepare)

8
a. Digital Input:To enable external speed control, connect one of the digits from Di1/2/3/4
to COM. See schematic as below:
b. Relay Output: Connect terminal L & N to enable external control. An additional on-offRelay
is necessary while bearing power is less than 500W (2.5A). See schematic as below:
c. RS485: To enable external control pump running capacity, connect terminal A and B, via
Modbus485 communication protocol.
8. TROUBLE SHOOTING
RS485
Display board
Relay external control output
Ce manuel convient aux modèles suivants
1
Table des matières
Langues :
Manuels Pompe de piscine populaires d'autres marques

Resol
Resol DeltaSol B Pro Manuel utilisateur

Evolution Aqua
Evolution Aqua UniTech Perfect 5000 Manuel utilisateur

Outside Living Industries
Outside Living Industries Ubbink Heatermax Pool Guide de démarrage rapide

CPI
CPI Olympic 2P1815 Manuel utilisateur

Flotec
Flotec FP6121-01 Manuel utilisateur

Pentair
Pentair ONGA LEISURETIME LTP400 Manuel utilisateur