Interflex Opendor IF-261 Manuel utilisateur

IF-261 Cabinet Lock
Opendor
OF-261-xxxx

© 2021 Interflex Datensysteme GmbH IF-261 Cabinet Lock 2
1 General information.......................................................................................................................... 3
1.1 Short description ......................................................................................................................... 3
1.2 Range of functions ...................................................................................................................... 3
1.3 Scope of delivery ........................................................................................................................ 3
1.4 Intended use ............................................................................................................................... 4
1.5 Target group ............................................................................................................................... 4
1.6 Notes on safety ........................................................................................................................... 4
2 Installation and programming ......................................................................................................... 5
2.1 Dimensions ................................................................................................................................. 5
2.2 Installation situation .................................................................................................................... 7
2.3 Measurement and calculation ..................................................................................................... 8
2.4 Installation................................................................................................................................... 10
2.5 Programming .............................................................................................................................. 15
3 Operation........................................................................................................................................... 15
3.1 Opening a door ........................................................................................................................... 15
3.2 Activating/deactivating the permanently open mode .................................................................. 16
4 Maintenance, cleaning, and disinfection........................................................................................ 16
5 Battery replacement ......................................................................................................................... 17
6 Technical specifications .................................................................................................................. 18
7 Disposal............................................................................................................................................. 19
8 Declarations of Conformity.............................................................................................................. 19
8.1 EU Declaration of Conformity ..................................................................................................... 19
8.2 UKCA Declaration of Conformity ................................................................................................ 19

1 General information
© 2021 Interflex Datensysteme GmbH IF-261 Cabinet Lock 3
1 General information
1.1 Short description
The electronic IF-261 Cabinet Lock from the Opendor line of products
provides the highest level of security for storage cabinets and lockers.
The Cabinet Lock is the ideal solution for cost-effective, uncomplicated
and wireless compliance with current security standards for a wide
range of applications.
The key feature of the Cabinet Lock from Interflex is that it can be
easily integrated into the access control systems IF-6020 and IF-6040:
nCabinet Lock card reads the access permissions stored on RFID
credentials via proven NetworkOnCard technology.
nCabinet Lock air reads the digital key on credentials or smartphones
via RFID/NFC or Bluetooth technology and evaluates the stored
access permissions from the IF-6040 access control system online
in real time, or offline in the Cabinet Lock.
Together with the IF-4041 Gateway from Interflex and the latest BLE 5
technology, the Cabinet Lock offers all the benefits of a state-of-the-art
wireless online system.
1.2 Range of functions
Main functions of the cabinet lock IF-261:
nContactless identification via credential or smartphone
nCabinet Lock air with wireless online and offline operating mode
nSelf-learning access control list used by Cabinet Lock air to control access in offline mode
nSecurity management with a Secure Element
nCertificate-based encryption with Cabinet Lock air
nBooking response via LEDs and buzzer when credential is being read
1.3 Scope of delivery
The package contains:
nIF-261 Cabinet Lock consisting of lock and reader unit
n2 lithium batteries, type AA 1.5 V
nSpacer plates, variable spacer plate, locking blocks and flange extensions
nInstallation tools
nMounting material
n95-10434 product info
Check the completeness and condition of the goods upon receipt and report any damage caused
during transport immediately.

1 General information
© 2021 Interflex Datensysteme GmbH IF-261 Cabinet Lock 4
1.4 Intended use
The IF-261 Cabinet Lock is designed to open and close storage cabinets and lockers with passive
identification media and smartphones.
1.5 Target group
This document is solely intended for experts and people trained in electrical engineering.
Only perform the actions described in this document if you belong to this target group. Interflex
Datensysteme GmbH is not liable for any damages caused by improper installation or initial
operation.
1.6 Notes on safety
General
NOTICE
Malfunction due to radio interference
This product may be affected by electromagnetic or magnetic interference.
uDo not place the product directly next to devices that can cause electromagnetic or magnetic
interference, especially not near switching power supplies.
NOTICE
Damage due to electrostatic discharge (ESD)
Electrical components and modules can be damaged by only slight, hardly noticeable electrostatic
discharge (ESD) without this becoming immediately obvious. ESD damages result in malfunctions and
even failure of the product.
uMake sure that effective protective measures against electrostatic discharge are in place when
working on the open device.
NOTICE
Blocked access due to improper mounting or faulty programming
If you modify the product without authorization, malfunctions may occur and access may be blocked.
uUse the product only as specified in the documentation.
Batteries
CAUTION
Risk of explosion due to incorrect battery type
Inserting the wrong type of battery can cause an explosion.
uOnly use the batteries specified in the technical specifications.

2 Installation and programming
© 2021 Interflex Datensysteme GmbH IF-261 Cabinet Lock 5
NOTICE
Batteries can be a fire hazard
Batteries may pose a fire or burn hazard if handled incorrectly.
uDo not attempt to charge, open, heat or incinerate the batteries.
uDo not short circuit the batteries.
2 Installation and programming
2.1 Dimensions
Dimensions of the reader unit

2 Installation and programming
© 2021 Interflex Datensysteme GmbH IF-261 Cabinet Lock 6
Dimensions of the lock

2 Installation and programming
© 2021 Interflex Datensysteme GmbH IF-261 Cabinet Lock 7
2.2 Installation situation
Observe the minimum and maximum distances allowed when installing the Cabinet Lock:
Door frames
Angle
brackets
Spacer plates
Variable spacer plate
Door
Installation of Cabinet Lock on wooden door
Door frames
Angle
brackets
Spacer plates
Variable spacer plate
Door
Installation of Cabinet Lock on metal door 1

2 Installation and programming
© 2021 Interflex Datensysteme GmbH IF-261 Cabinet Lock 8
Door
frames
Angle
brackets
Spacer plates
Variable spacer plate
Door
Installation of Cabinet Lock on metal door 2
2.3 Measurement and calculation
To install the cabinet lock, you will need different spacer plates, locking blocks, flange extensions and
screws, depending on local conditions.
1. Measure spacing between the inside of the door and the bolt stop, e.g. using the depth measuring
stick of a slide caliper gauge
2. Measure the thickness of the door or the door panel
3. Refer to the table for the required number of spacer plates and appropriate locking blocks
Inside of the door up to the bolt stop [mm] Spacer plate [mm] Locking block
0.0 to 5.95 None 4
6.05 to 7.25 None 3
7.35 to 8.85 None 2
8.95 to 10.45 None 1
10.55 to 10.95 5 4
11.05 to 12.25 5 3
12.35 to 13.85 5 2
13.95 to 15.45 5 1
15.55 to 15.95 2 × 5 4

2 Installation and programming
© 2021 Interflex Datensysteme GmbH IF-261 Cabinet Lock 9
Inside of the door up to the bolt stop [mm] Spacer plate [mm] Locking block
16.05 to 17.25 2 × 5 3
17.35 to 18.85 2 × 5 2
18.95 to 20.45 2 × 5 1
20.55 to 20.95 3 × 5 4
21.05 to 22.25 3 × 5 3
22.35 to 23.85 3 × 5 2
23.95 to 25.45 3 × 5 1
The number embossed in the locking block denotes the length:
Number Length [mm]
1 10.4
2 9.1
3 7.5
4 5.9
4. Remove the required number of flange extensions and appropriate screw lengths from the table
Door /door panel thickness + spacer plates
[mm]
Flange extensions Screw [mm]
10 to 16.0 None M4×16
16.1 to 19.0 1× M4×20
19.1 to 25.0 2× M4×25
25.1 to 30 3× M4×30
Get in touch with your Interflex contact, if you need additional parts

2 Installation and programming
© 2021 Interflex Datensysteme GmbH IF-261 Cabinet Lock 10
2.4 Installation
Lock and reader unit are permanently assigned to one another and may not be interchanged.
Tools included in delivery
nHexagon key 0.9mm
nAssembly tool
nSpecial tool for guiding cables
Additionally required tools
nPhillips screw driver PH1
nFlat-bladed screwdriver (if locking block has to be replaced)
nHexagon key 2.5mm
Prerequisites
üCabinet lock closed, bolt extended
üDoor and parts measured [}8]
Procedure
1. Press the cover of the reader unit lightly against the bottom and
turn the lower screw clockwise inwards until you are able to lift the
cover off
2. Carefully press the light conductors down and remove the cover
3. Use needle-nose pliers to pull off the cable connector below the
circuit board
4. Disassemble reading unit and lock
Table des matières