Intellijel Zeroscope 1U Manuel utilisateur

1/8/2019 Zeroscope 1U Manual - Google Docs
https://docs.google.com/document/d/11f-r1wXdM0R0YPFTe9TY-U185nvz2PQHx-hAHVGTYTk/edit#heading=h.jm4q10wdqtr1 1/13
Zeroscope 1U Manual
Zeroscope 1U
Dual Channel Oscilloscope, Frequency Meter and Tuner
Manual Revision: 2019.01.08

1/8/2019 Zeroscope 1U Manual - Google Docs
https://docs.google.com/document/d/11f-r1wXdM0R0YPFTe9TY-U185nvz2PQHx-hAHVGTYTk/edit#heading=h.jm4q10wdqtr1 2/13
Zeroscope 1U Manual
Table of Contents
Table of Contents
Compliance
Installation
Before Your Start
Installing Your Module
Front Panel
Inputs & Outputs
Controls
Basic Operation
Advanced Operation
Scope Type
Using Tune Mode
Hz Display
Note Name Display
Reference Pitch and Averaging Time
Trigger Source
Trigger Detection Level
CH1 Offset
CH2 Offset
Grid Display
Technical Specifications
Firmware Changelog
1.2 (Jan 08, 2019)
Page 1

1/8/2019 Zeroscope 1U Manual - Google Docs
https://docs.google.com/document/d/11f-r1wXdM0R0YPFTe9TY-U185nvz2PQHx-hAHVGTYTk/edit#heading=h.jm4q10wdqtr1 3/13
Zeroscope 1U Manual
Compliance
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
Changes or modifications not expressly approved by Intellijel Designs, Inc. could
void the user’s authority to operate the equipment.
Any digital equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio
communications.
This device meets the requirements of the following standards and directives:
EMC: 2014/30/EU
EN55032:2015 ; EN55103-2:2009 (EN55024) ; EN61000-3-2 ; EN61000-3-3
Low Voltage: 2014/35/EU
EN 60065:2002+A1:2006+A11:2008+A2:2010+A12:2011
RoHS2: 2011/65/EU
WEEE: 2012/19/EU
Page 2

1/8/2019 Zeroscope 1U Manual - Google Docs
https://docs.google.com/document/d/11f-r1wXdM0R0YPFTe9TY-U185nvz2PQHx-hAHVGTYTk/edit#heading=h.jm4q10wdqtr1 4/13
Zeroscope 1U Manual
Installation
This module is designed for use within an
Intellijel-standard 1U row, such as
contained within the Intellijel 4U and 7U
Eurorack cases. Intellijel’s 1U specification
is derived from the Eurorack mechanical
specification set by Doepfer that is
designed to support the use of lipped rails
within industry standard rack heights.
Before Your Start
Intellijel Eurorack modules are designed to be used with a Eurorack-compatible case and power
supply. We recommend you use Intellijel cases and power supplies.
Before installing a new module in your case, you must ensure your power supply has a free
power header and sufficient available capacity to power the module:
● Sum up the specified +12V current draw for all modules, including the new one. Do the
same for the -12 V and +5V current draw. The current draw will be specified in the
manufacturer's technical specifications for each module.
● Compare each of the sums to specifications for your case’s power supply.
● Only proceed with installation if none of the values exceeds the power supply’s
specifications. Otherwise you must remove modules to free up capacity or upgrade your
power supply.
You will also need to ensure your case has enough free space (hp) to fit the new module. To
prevent screws or other debris from falling into the case and shorting any electrical contacts, not
leave gaps between adjacent modules, and cover all unused areas with blank panels. Similarly,
do not use open frames or any other enclosure that exposes the backside of any module or the
power distribution board.
Page 3

1/8/2019 Zeroscope 1U Manual - Google Docs
https://docs.google.com/document/d/11f-r1wXdM0R0YPFTe9TY-U185nvz2PQHx-hAHVGTYTk/edit#heading=h.jm4q10wdqtr1 5/13
Zeroscope 1U Manual
You can use a tool like ModularGrid to assist in your planning. Failure to adequately power your
modules may result in damage to your modules or power supply. If you are unsure, please
contact us before proceeding.
Installing Your Module
When installing or removing a module from
your case always turn off the power to the
case and disconnect the power cable. Failure
to do so may result in serious injury or
equipment damage.
Ensure the 10-pin connector on the power
cable is connected correctly to the module
before proceeding. The red stripe on the
cable must line up with the -12V pins on the
module’s power connector. The pins are
indicated with the label -12V, a white stripe
next to the connector, the words “red stripe”,
or some combination of those indicators.
Most modules will come with the cable
already connected but it is good to double
check the orientation. Be aware that some modules may have headers that serve other
purposes so ensure the cable is connected to the right one.
The other end of the cable, with a 16-pin
connector, connects to the power bus
board of your Eurorack case. Ensure the
red stripe on the cable lines up with the
-12V pins on the bus board. On Intellijel
power supplies the pins are labelled with
the label “-12V” and a thick white stripe:
If you are using another manufacturer’s
power supply, check their documentation
for instructions.
Page 4

1/8/2019 Zeroscope 1U Manual - Google Docs
https://docs.google.com/document/d/11f-r1wXdM0R0YPFTe9TY-U185nvz2PQHx-hAHVGTYTk/edit#heading=h.jm4q10wdqtr1 6/13
Zeroscope 1U Manual
Once connected, the cabling between the module and power supply should resemble the
picture below:
Before reconnecting power and
turning on your modular
system, double check that the
ribbon cable is fully seated on
both ends and that all the pins
are correctly aligned. If the pins
are misaligned in any direction
or the ribbon is backwards you
can cause damage to your
module, power supply, or other
modules.
After you have confirmed all the
connections, you can reconnect
the power cable and turn on
your modular system. You should immediately check that all your modules have powered on
and are functioning correctly. If you notice any anomalies, turn your system off right away and
check your cabling again for mistakes.
Page 5

1/8/2019 Zeroscope 1U Manual - Google Docs
https://docs.google.com/document/d/11f-r1wXdM0R0YPFTe9TY-U185nvz2PQHx-hAHVGTYTk/edit#heading=h.jm4q10wdqtr1 7/13
Zeroscope 1U Manual
Front Panel
Inputs & Outputs
1. CH 1 input: The input is DC coupled and accepts signals between -10V and +10V.
2. CH 2 input: This input, like CH1, is DC coupled and accepts signals between -10V and
+10V.
3. CH 1 output: The signal appearing at the CH1 input jack is normalled to the CH1
output jack, so signals pass unimpeded through the Zeroscope1U. This allows you to
monitor signals without needing to re-patch or use signal multipliers.
4. CH2 output: As with CH1, the signal appearing at the CH2 input jack is normalled to
the CH2 output jack, so signals pass unimpeded through the Zeroscope 1U.
Controls
A. Scope: In Scope or X-Y modes, this screen displays both the CH1 and CH2
waveforms, while in Tune mode, it displays their frequency by either Hz or note name.
B. Encoder: This push-function encoder serves multiple functions — controlling the
appearance of the scope, and enabling both the selection of parameters and the editing
of their values.
Page 6

1/8/2019 Zeroscope 1U Manual - Google Docs
https://docs.google.com/document/d/11f-r1wXdM0R0YPFTe9TY-U185nvz2PQHx-hAHVGTYTk/edit#heading=h.jm4q10wdqtr1 8/13
Zeroscope 1U Manual
Basic Operation
In its basic mode, Zeroscope1U displays the waveforms for
both CH1 and CH2, and gives you control over the display
height of these two waveforms plus their displayed
periodicity.
1. Connect CV or audio signals to either or both
the CH1 and CH2 inputs.
Both inputs are DC coupled and accept signals
between -10V and +10V. Either can serve as a
trigger source, configured to detect either the rising
or falling edge of the waveform (as described later in
the Trigger Source discussion).
All inputs are normalled to the jacks below.
2. Press the encoder to cycle through the three
three basic display options.
Specifically, each press cycles between:
●CH1 Display Value (volts/division)
●CH2 Display Value (volts/division)
●T (Time) Display Value (seconds/division, both channels)
3. Turn the encoder to change the option’s value.
Specifically:
●CH1: With this option displayed, turning the encoder sets CH1’sgain (height of
displayed signal) between 0.5volts/division and 10.0volts/division.
●CH2: With this option displayed, turning the encoder sets CH2’s gain (height of
displayed signal) between 0.5volts/division and 10.0volts/division. CH2’s gain
level is completely independent from CH1’s.
●T: With this option displayed, turning the encoder sets the waveform’s time base
between 10 s/div and 10 µs/div with seventeen incremental values between
these two extremes.
NOTE: At a setting of 10µs/div, only CH1 is displayed. Also, because the
Zeroscope employs a simple anti-aliasing filter, an input signal running at a
frequency higher than the timebase may produce a misleading waveform.
Page 7

1/8/2019 Zeroscope 1U Manual - Google Docs
https://docs.google.com/document/d/11f-r1wXdM0R0YPFTe9TY-U185nvz2PQHx-hAHVGTYTk/edit#heading=h.jm4q10wdqtr1 9/13
Zeroscope 1U Manual
Advanced Operation
Zeroscope1U offers several advanced display and triggering options, located within a
Advanced Settings menu.
1. Long-press (>1 sec) the encoder to open the Advanced Settings menu.
A small menu of options appears to the right of the display.
2. Turn the encoder to select and highlight which of six Advanced Settings options
you wish to edit.
There are six options accessible in this menu. These are, from top-to-bottom:
●SCOPE type
●TRIGGER Source
● TRIGGER DETECTION LEVEL
●CH1 offset
●CH2 offset
●GRID display
3. With the desired option highlighted, push-turn the encoder to edit its value.
That is, turn the encoder while it’s fully depressed to change values. The following
sections discuss each advanced operation in detail.
Page 8

1/8/2019 Zeroscope 1U Manual - Google Docs
https://docs.google.com/document/d/11f-r1wXdM0R0YPFTe9TY-U185nvz2PQHx-hAHVGTYTk/edit#heading=h.jm4q10wdqtr1 10/13
Zeroscope 1U Manual
Scope Type
With this option selected, push-turn the encoder to select what you want displayed on the
Zeroscope. There are three options:
Scope Standard graphical display, with time displayed on the X-axis and voltage
displayed on the Y-axis.
X-Y Alternate graphical display with CH1 driving the X-axis and CH2 driving the
Y-axis.
Tune Alphanumerical tuning display, which you can configure to show either Hz
values or note names (see below).
Using Tune Mode
Tune Mode displays CH1 and CH2 frequency either by number of cycles-per-second
(Hz) or by Note Name. Once in Tune mode, simply press the encoder to toggle between
the two display options.
NOTE: The input signal must be at least 1V in order for the pitch detector to work.
Hz Display
The top line displays the frequency (in Hz)
of the signal appearing at CH1, and the
second line displays the frequency of the
signal appearing at CH2.
Page 9
Autres manuels pour Zeroscope 1U
1
Table des matières
Autres manuels Intellijel Équipement de test
Manuels Équipement de test populaires d'autres marques

SMART
SMART KANAAD SBT XTREME 3G Series Manuel utilisateur

Agilent Technologies
Agilent Technologies BERT Serial Manuel utilisateur

Agilent Technologies
Agilent Technologies N3280A Manuel utilisateur

Vernier
Vernier Go Direct Voltage Manuel utilisateur

Lifeloc
Lifeloc R.A.D.A.R. Manuel utilisateur

Fluke
Fluke T5-600 Instructions d'utilisation et d'installation