SC2-AT6 – UserManual
2 Installation
Electronics can be destroyed by electrostatic discharge (ESD). Therefore installation work should
be done only by persons connected to ground, e. g. by standing on a conductive oor or by taking
appropriate grounding measures (acc. to DIN EN 100015).
2.1 Mounting Instructions
• Choose mounting location of the sensor
according to the local regulations.
• Consider ventilation conditions! Do not
mount the sensor near the airow (air
passages, suction holes etc.).
• Mount the sensor at a location with
minimum vibration and minimum variation
in temperature (avoid direct sunlight).
• Avoid locations where water, oil etc. may
inuence proper operation and where
mechanical damage might be possible.
• Provide adequate space around the
sensor for maintenance and calibration
work.
INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com
Specifications subject to change without notice. | USA 200303 | Page 5of 5
ORDERING INFORMATION
SC2 - XXXXX-X
SC2
Example, ordering part number:
SC2-E1110-E
Conguration includes:
X-Change Replacement Sensor:
• Carbon Monoxide, 0-250 ppm
Gas Sensor & Range
# TOXIC GASES AND OXYGEN
Coverage
Area (ft2), Max.
Mounting
Height (ft)
E1110-E Carbon Monoxide CO 0-250 ppm 7,500 5-6
E1110-F Carbon Monoxide CO 0-300 ppm 7,500 5-6
E1130-A Nitrogen Dioxide NO20-10 ppm 7,500 5-6
E1130-B Nitrogen Dioxide NO20-20 ppm 7,500 5-6
E1130-C Nitrogen Dioxide NO20-30 ppm 7,500 5-6
E1130-D Nitrogen Dioxide NO20-500 ppm 7,500 5-6
E1129-C Nitric Oxide NO 0-100 ppm 5,000 5-6
E1129-D Nitric Oxide NO 0-1000 ppm 5,000 5-6
E1125-C Ammonia NH30-300 ppm 4,000 Ceiling
E1125-D Ammonia NH30-1000 ppm 4,000 Ceiling
E1193-C Chlorine Cl20-10 ppm Near Source Floor
E1183-C Hydrogen Cyanide HCN 0-100 ppm Near Source Ceiling
E1189-C Ethylene C2H40-200 ppm 5,000 5-6
E1185-B Formaldehyde CH2O 0-10 ppm Contact Rep Floor
E1190-A Ozone O30-5 ppm 5,000 Floor
E1196-B Sulfur Dioxide SO20-20 ppm 5,000 Floor
E1197-A Hydrogen Sulde H2S 0-50 ppm 5,000 Floor
E1195-A Oxygen O20-25 Vol% 5,000 5-6
# INFRARED SENSORS
Coverage
Area (ft2), Max.
Mounting
Height (ft)
I1164-A Carbon Dioxide CO20-2000 ppm 7,500 5-6
I1164-B Carbon Dioxide CO20-5 Vol% 7,500 5-6
I1164-C Carbon Dioxide CO20-2 Vol% 7,500 5-6
# COMBUSTIBLE GASES
Coverage
Area (ft2), Max.
Mounting
Height (ft)
P3485-A Acetone C3H6O 0-100% LEL 4,000 Floor
P3408-A Ammonia NH30-100% LEL 4,000 Ceiling
P3496-A Gasoline Vapors - 0-100% LEL 4,000 -
P3460-A Butane C4H10 0-100% LEL 4,000 Floor
P3472-A Cyclopentane C5H10 0-100% LEL 4,000 Floor
P3427-A Ethyl Acetate C4H8O20-100% LEL 4,000 Floor
P3425-A Ethyl Alcohol C2H5OH 0-100% LEL 4,000 Floor
P3410-A Ethylene C2H40-100% LEL 4,000 Ceiling
P3491-A Heptane C7H16 0-100% LEL 4,000 Floor
P3435-A Hexane C6H14 0-100% LEL 4,000 Floor
P3476-A Isopentane C5H12 0-100% LEL 4,000 Floor
P3482-A Isopropyl Alcohol C3H8O 0-100% LEL 4,000 Floor
P3498-A JP8 - 0-100% LEL 4,000 -
P3402-A LPG - 0-100% LEL 4,000 -
P3400-A Methane CH40-100% LEL 4,000 Ceiling
P3450-A Methanol CH3OH 0-100% LEL 4,000 Floor
P3458-A Methyl Ethyl Ketone C4H8O 0-100% LEL 4,000 Floor
P3475-A Pentane C5H12 0-100% LEL 4,000 Floor
P3480-A Propane C3H80-100% LEL 4,000 Floor
P3484-A Propyl Alcohol C3H8O 0-100% LEL 4,000 Floor
P3490-A Toluene C7H80-100% LEL 4,000 Floor
P3440-A Hydrogen H20-100% LEL 4,000 Ceiling
# ACCESSORIES
XC-CAP (1) Replacement protective sensor cap
PG2-
DUCTKIT (1) Duct mounting kit for SC2 / AT6 sensor