Insignia AIO 7.5kW Manuel utilisateur

Installation Guide
Signature 12kW
Steam Generator
Should you require additional assistance with the
installation of your product,
please call 01908 317512
or email
customerservices@insigniashowers.com.

www.insigniashowers.com Last Modied: 06/05/2022
INSTALLATION MANUAL
Signature Steam Generators
ATTENTION INSTALLERS:
These instrucons must be
le with the customer CHECK ALL CONTENTS BEFORE BUILD COMMENCES. NO RETURNS CAN BE MADE
ONCE THE BUILD HAS STARTED AS IT IS DEEMED ACCEPTANCE OF PRODUCT!
30 Day Technical Support:
Call 01908 317512 and request technical support for aiding your
installaon.
Replacements Parts: Inside of your warranty period visit:
hps://www.insigniashowers.com, click support and make a
warranty claim.
Spares/Replacements Parts: Outside of your warranty period visit
hps://www.insigniashowers.com/replacement-parts.html

www.insigniashowers.com Last Modied: 06/05/2022
02
Contents
Thank you for your purchase 3
Installaon Advice 4
Models, Parameters and Dimensions 5
Steam Generator Construcon 6
Installaon of the Steam Generator Body 8
Central Funcon Box 9
Control Panel Installaon 10
Temperature Sensor Installaon 11
Pipeline Installaon 12
Installaon of the Generator 16
Lights Installaon 18
Aroma Pump Installaon 19
Descaling Pump System Installaon 22
Exhaust Fan Installaon 23
Salt Spray Generator Installaon 25
Water Processor Installaon 27
Emergency Alarm System Installaon 29
Commercial Mode — Fast Steam 30
Door Control System 32
Installaon Diagram 33
Electrics 34
Control Panel Interface 35
Control Panel Operaonal Instrucons 36
Maintenance 39
Troubleshoong 40
Warranty 42
Steam Room Safety Guide 43
WEEE Compliance Statement 44

www.insigniashowers.com Last Modied: 06/05/2022
03
Thank you for your recent purchase of an Insignia steam generator. Please read this
booklet with great care to ensure you get the best out of your install and have a steam
unit that will last for many years to come! Like everything, in order to obtain a rst
class product that will serve you well for many years, the eort and correctness put
into the install will reect in the quality of your nish.

www.insigniashowers.com Last Modied: 06/05/2022
04
Installaon Advice
1. If the generator is installed at a place where access is dicult, the water supply valve must be easy to access for emergencies.
2. A GFCI must be installed on the power supply, power wire, fuse and breaker must comply with the nameplate on the unit and the table (next page).
3. The solenoid valve can endure maximum 0.8MPa (8kg/cm2) water pressure. To protect the solenoid valve from extremely high water pressure, please
turn down the inlet slightly or install water pressure reducing valve.
4. Do not install saddle-backed or needle valves on the inlet. Please dredge and clean the pipe before installaon.
5. Strictly no blocked or blended pipes, otherwise this will have a negave eect on the ow of steam and condensate. The steam pipelines should be
installed with a slight angle so that the condensate can ow back to the generator or the steam head.
6. Steam generator should be installed indoor to avoid freezing.
7. The generator should be installed and leveled with the arrow poinng upward at an easy-access place, otherwise do not switch on.
8. The steam pipeline must be copper pipes or stainless-steel pipes, all other material such as plasc, acrylic must not be used since they cannot endure
150°C or higher temperature.
9. All inlet and apertures should be sealed to prevent any steam escaping and to protect the generator and yourself.
10. Do not drain water into the steam room from the water tank as may scald, causing serious injury or damage to the steam room.
11. All inlet water pipes and steam pipelines should be built according to the Naonal Standard and this should be done before sealing the wall.

www.insigniashowers.com Last Modied: 06/05/2022
05
Model/Power Phase Heang Elements Voltage/Current Power Wire Breaker Room Volume Dimensions
kW 1/3 Number x kW V/A Number x Amps m³ Length x Width x Height
AIO 7.5kW 13 x 2.5 215-240/33.75 3 x 6.0 60 6.5—9475 x 185 x 450
AIO 7.5kW 33 x 2.5 380-415/11.25 5 x 2.5 16 6.5—9475 x 185 x 450
AIO 10.5kW 33 x 1.5 + 3 x 2 380-415/15.9 5 x 2.5 25 9—12 475 x 185 x 450
AIO 12kW 36 x 2 380-415/18.2 5 x 2.5 25 11—14 475 x 185 x 450
AIO 15kW 36 x 2.5 380-415/22.7 5 x 2.5 32 13—18 510 x 185 x 460
AIO 18kW 39 x 2 380-415/27.3 5 x 4 40 16—22 510 x 185 x 460
Models, Parameters and Dimensions
1. The rated power is measured under single phase 230V, therefore the actual operang power under single phase 215-240V, 50/60Hz,
or three phases 380-415V, 50/60Hz may be dierent from the rated value.
2. The 7.5kW generator, can be made as 215-240V single phase or 380-415V three phases. Please note the earth wire should not be less
than 1.5mm², the live wire and null wire should not less than 2.5mm².
3. The 10.5kW, 12kW, 15kW and 18kW generators, can be only be installed by 380-415V three phases. Please note the earth wire should
not be less than 2.5mm², the live wire and null wire should not be less than 4.0mm².
How to choose the right kW steam generator?
On our website we have an online calculator to give you the informaon on exactly what steam generator we recommend for your steam
room.
hps://www.insigniashowers.com/steam-generator-sizing

www.insigniashowers.com Last Modied: 06/05/2022
06
1
18 17 16 15
32 456
8 9 10
14 13 12 11
7
1. Front Cover
2. Wire entry hole
3. Small cover
4. Sub-board (relay board)
5. Wire terminal
6. U shape cover
7. Water inlet posion
8. Steam outlet
9. Water level sensor
10. Inner tank
11. Back Cover
12. Water inlet hose
13. Solenoid water inlet valve
14. Element access cover
15. Heang elements
16. Base Plate
17. Safety valve
18. Base plate
Steam Generator Construcon

www.insigniashowers.com Last Modied: 06/05/2022
07
1
2
3
4
65
12
9
7
8
10 11
13
14
Steam Generator Construcon
1. Steam outlet
2. Safety valve
3. Heang elements
4. Solenoid water inlet valve
5. Drain valve
6. Drain pipe
7. High-temperature protecon
8. Wire terminal
9. Sub-board (relay)
10. Water level sensor
11. Temperature sensor
12. Inner water tank
13. Central box
14. Controller

www.insigniashowers.com Last Modied: 06/05/2022
08
Installaon of steam generator body
Switch o all power supply before installaon, and check whether you have the correct model for your steam room according to table (page 5).
Do not install the generator outdoors, in wet, freezing, or corrosive places. Do not install the generator
near to inammables such as oil paint, diluents and fuel. Be mindful of the steam pipeline and safety
valve since the high temperature of steam is dangerous in very close proximity.
The generator MUST be installed as per the orientaon denoted by image (right), level and all vents on
the unit free from obstrucon.
The generator MUST be installed in a dry and very well-venlated place - minimum requirement of
1.3 cubic meter of air space is required. Never starve the unit of air as it could cause the unit to enter into
heat protecon mode and could damage the unit.
The generator can be installed either on the wall or on the ground but must be well xed. Install the
generator as close as possible to the steam room.
To install the generator on the wall, drill two small holes with diameter of 8mm on the wall and insert the expansion screws, then hang the generator on
those screws (not supplied).
To install the generator on the ground, install a frame on the site and then screw the generator into the frame.
The central funcon box should be installed as near to the steam generator as possible, as the length of the cable (connecng the steam generator and the
central funcon box) is 500mm. Only the cable provided will work with the system, do not extend the cable.
For beer service and maintenance, please install the generator with the nameplate face to front and leave more than 250mm space around the generator.

www.insigniashowers.com Last Modied: 06/05/2022
09
1. APP (Not funconal)
2. Steam room temperature sensor
3. Controller
4. Steam room humidity sensor
5. Fast steam switch
6. Fan
7. Coloured lights
8. Salt spray generator
9. Aroma pump
10. Descaling pump
11. Connector to the steam generator
12. Power supply 12V DC
Central Funcon Box
Steam generator 12-core cable socket corresponding funcons
Ce manuel convient aux modèles suivants
4
Table des matières
Autres manuels Insignia Fer