Innova EF15 Manuel utilisateur

PLEASE SAVE THIS
MANUAL FOR
FUTURE REFERENCE.
READ THIS MANUAL CAREFULLY.
SEE INSIDE COVER FOR IMPORTANT
INFORMATION ABOUT THIS MANUAL.
KEEP INSTRUCTION WITH
APPLIANCE FOR FUTURE REFERENCE.
Version 2022705
FOR MODELS:
EF15, EF17, EF18, EF19
INSTALLATION, INSTRUCTION
& SERVICE MANUAL

2www.InnovaHeatingCo.com
Thank you for choosing Innova Heating Co. to
meet your heating needs. This manual is designed
for our EF15, EF17, EF18, and EF19 series of heaters.
In order to ensure your heater provides efficient,
safe and comfortable heat, please take the time
to review this manual.
Before installing your heater, review the safety
information found on page 4, page 5 and page 9.
Strict adherence to these guidelines is necessary
to prevent personal injury or property damage.
Pages 9 through 16 reviews essential installation
and assembly instructions, containing placement
and orientation guidelines that are extremely
important to a safe and efficient installation.
Please keep this manual in a safe place for future
reference and urgent needs.
Please contact our customer service department
or visit our website at https://innovaheatingco.com
for the latest instruction manual.
Note: Innova Heating Co. reserves the right to make changes to specifications, parts, components and equipment without prior notification.
This Installation, operation and service manual may not be reproduced in any form without prior written consent from Innova Heating.
Head Office:
33 West Beaver Creek Road, Richmond Hill, ON L4B 1L8 Canada
Tel: 1.800.660.5391
www.InnovaHeatingCo.com
Pat. www.InnovaHeatingCo.com/patents
Thank You

3
www.InnovaHeatingCo.com
Contents
WARNINGS........................................................................................ Page 4
OVERVIEW .........................................................................................Page 6
APPLICABLE CODES & STANDARDS.................................................Page 7
TECHNICAL SPECIFICATIONS ...........................................................Page 7
ELECTRICAL INSTALLATIONS ............................................................Page 8
MOUNTING HEIGHT / CLEARANCES................................................ Page 9
CEILING MOUNT, WALL MOUNT, FLUSH MOUNT............................Page 10
INSTALLING QUARTZ ELEMENT........................................................ Page 11
MAINTENANCE INSTRUCTIONS .......................................................Page 12
TECHNICAL SERVICE.........................................................................Page 12
REPLACEMENT PARTS....................................................................... Page 13
GENERAL NOTES ..............................................................................Page 13
MANUFACTURER WARRANTY...........................................................Page 14
Contents

4www.InnovaHeatingCo.com
PLEASE READ ALL INSTRUCTIONS PRIOR
TO INSTALLING OR USING HEATER.
This unit may cause a shock or possible ignition if service
is attempted without first disconnecting its power source.
Keep electrical cords, drapery, furnishings and other combustible
materials at least 3.3ft (1m) from the heater’s front fascia and keep them
away from the two sides and rear.
A LICENSED ELECTRICIAN IS
REQUIRED TO INSTALL THIS PRODUCT.
WALL & CEILING HEIGHT/CLEARANCES
For the Canadian market, Heater must be installed more than 8ft (2.4m)
off the floor.
For the American market, Heater must be installed more than 6ft (1.8m)
off the floor.
• All adjacent heaters must be installed more than 3.3ft (1m) apart from each other.
• Heater should never be blocked by any other object.
• Heater should not be operated within 25ft (7.6m) of any flammable or explosive
materials.
• Heater is not to be used if the heating element is damaged or cracked.
• According to local wiring codes, disconnection provisions should be incorporated
in the appliance.
• When possible, install heaters under a protective covering such as a roof when it is used
in an outdoor application. This will prolong the product’s life and maintain its appearance.
WALL-MOUNTED CEILING-MOUNTED
Min. distance from adjacent wall 18” 18”
Min. distance from ceiling 12” 6”
Min. distance from vertical surface 18” 18”
Min. distance from floor 72” for UL Listed.
96” for CUL Listed
72” for UL Listed.
96” for CUL Listed
For optimal heater
performance and
longevity, a 15 minute
cool down period is
recommended after
4 hours of continuous
usage.
GOOD
TO
KNOW!
Warnings

5
www.InnovaHeatingCo.com
Read and understand the installation, operating, and maintenance
instructions thoroughly before installing or servicing this
equipment. Only trained, qualified personnel with proper electrical
experience may install or service this equipment. Improper
installation, adjustment, alteration, service, or maintenance can
cause property damage, serious injury, or death.
Damage caused by improper use is not the responsibility of the
manufacturer. It is important to use this appliance responsibly
and to follow all the procedures, warnings, and safety instructions
contained in this manual. Any use not recommended by the
manufacturer may result in fire, electric shock, or personal injury.
Some parts of this product can become very hot and cause burns.
Keep bare skin away from hot surfaces to avoid burns. The front,
sides, and rear of the heater should be at least 3.3ft (1m) away
from flammable materials such as furniture, pillows, linen, papers,
clothes, etc.
Placement of explosive objects, flammable objects, liquids, and
vapors close to the heater may result in explosion, fire, property
damage, serious injury, or death. Do not store or use explosive
objects, liquids, or vapors in the vicinity of the heater.
The outside surfaces of the heater are hot during operation and
after operation. If contact is made, permanent skin damage may
occur. Do not move, handle, or service the unit during operation
or while hot.
In order to avoid overheating, never under any circumstances
cover the appliances during operation, as this would lead to
dangerous overheating.
Failure to comply with the published clearances to combustibles
could result in personal injury, death, and/or property damage.
Particular attention must be given where children and vulnerable
people are present. Children should be kept away unless
continuously supervised.
If the power cable has been damaged, it must be replaced by
the manufacturer or the technical service center or by a qualified
person so as to avoid all risks.
Do not attempt to alter the unit in any manner, including painting
the surface of the unit.
Do not insert any foreign objects to the front cover or front
opening of the heater as this may cause an electric shock or fire or
damage the heater.
Do not operate any heater after it malfunctions. Disconnect
power at service panel and have heater inspected by a reputable
electrician before reusing.
INSTALLATIONS:
Installations must comply with local building codes; all electrical
connection must be in compliance with the National Electric
Code (NEC) and local codes for outdoor wiring. Contact the local
building inspector and/or fire marshal for guidance.
The packaging needs to be removed before installation, please
contact supplier if there is any damage or defectiveness on the
appliance.
Heater and switches should not be installed near bathtubs, wash
basins, showers, sinks, swimming pools, recreational vehicles,
boats, and wardrobes.
The appliance must not be located in front of or below a fixed
socket-outlet.
Before using the appliance check the label on the heater for
proper voltage, please make sure the requirement of the power
socket and power supply line correspond to the load specified.
Check the current capacity of your fuses. HEATER MUST
CONNECT TO EARTH PROVIDED SOCKET.
Safety warning labels must be maintained on the heater. Contact
either your local distributor or the product manufacturer for
obtaining replacement signs or labels.
Never place the power cable on top of the heater or under any
coverings. Power cord need to be placed away from the traffic
areas.
The heater can only mount horizontally to prevent from swaying
and putting stress on the heating elements. Check local codes for
seismic bracing requirements for outdoor heating equipment.
Air flow must not be restricted. The space above the heater must
not be enclosed in order to allow air for ventilation.
WARNING
Warnings
The heater should only be used as described in this manual. Any use not recommended
by the manufacturer may result in fire, electric shock, or personal injury.
CAUTION – High temperature, risk of fire, keep electrical cords, drapery,
furnishings, and other combustibles at least 3.3 feet (1m) from the front of
the heater and away from the side and rear.
Each enclosed area within which the heater is located shall have a
temperature control device.
The heater does not feature a device to control ambient temperature.
All users should be made aware of all aspects of operation and safety and
these instructions should be retained for reference.

6www.InnovaHeatingCo.com
Overview
1.
3.
2.
1. Standard Grill
2. Heater Body
3. Quartz Element
What’s in the box? Please inspect that all parts are included in the package.
Instruction Manual (x1)
Parts Bag:
Outer Nut (x2)
Washers (x2)
Mounting Brackets (x2)
Element (x1)

7
www.InnovaHeatingCo.com
Installation of this heater shall be in accordance with the National Electrical Code, NFPA 70, or the Canadian
Electrical Code, Part 1, C22.1, and any applicable local codes.
Innova Heaters are designed and manufactured for residential / commercial heating applications for indoor and
outdoor use, in accordance with the Standard for Fixed and Location-Dedicated Electric Room Heaters, UL 2021,
and the Canadian Standard for Electric Air Heaters, CSA C22.2 No. 46.
MODEL # OUTPUT
WATTAGE
SUPPLY
VOLTAGE
SUPPLY
AMP DRAW DIMENSIONS WEIGHT
EF15120 1500W 120V 12.5 42 ‘’ x 9 ‘’ x 9 ‘’
106.7 x 22.9 x 22.9cm 15.4 lbs (7Kg)
EF17120 1700W 120V 14.2 42 ‘’ x 9 ‘’ x 9 ‘’
106.7 x 22.9 x 22.9cm 15.4 lbs (7Kg)
EF18120 1800W 120V 15.0 42 ‘’ x 9 ‘’ x 9 ‘’
106.7 x 22.9 x 22.9cm 15.4 lbs (7Kg)
EF19120 1900W 120V 15.8 42 ‘’ x 9 ‘’ x 9 ‘’
106.7 x 22.9 x 22.9cm 15.4 lbs (7Kg)
Technical Specifications
Applicable Codes and Standards

8www.InnovaHeatingCo.com
Electrical Installations
HEATING ELEMENT
Junction Box
AC
120 V AC
EARTH
WIRE
WIRING DIAGRAM (For hard-wired application)
EF15, EF17,EF18 AND EF19
MODELS
WIRING DIAGRAM FOR
HARD-WIRED APPLICATION
USING INNOVA HEATING CO.
SWITCH MODELS EFSSPS1
AND EFSSPW1
(sold separately)
Please contact us or browse our website at www.innovaheatingco.com for more information.
ELECTRIC SHOCK HAZARD!
Serious injury or death may occur. Disconnect from electrical supply before installing
or servicing this heater. Read and follow installation requirements outlined in this
manual. The Appliance MUST be connected to a properly grounded electrical source.
L1
T1
Ground
Terre
Line Hot (Black)
Black Neutral (white)
Turn the heater on only when you need heat and avoid any misuse.
Do not use the heater if the ambient temperature exceeds 80°F (26.6°C). Before
connecting the appliance make sure that the voltage is the same as indicated on the
device and the line supply is corresponding to the relevant electrical code.
This heater MUST be permanently installed. An authorized/licensed electrician is
required for hard-wired installation. Do not perform maintenance, or carry out
installation or assembly procedure while electrical power is switched on.

9
www.InnovaHeatingCo.com
18”
(45.7 cm)
18”
(45.7 cm)
6”
(15.2 cm)
MIN
3’ (90 cm)
MIN
3’ (90 cm)
18”
(45.7cm)
MAX 30º
40”
(1 m)
12” (30.4 cm)
12” (30.4 cm)
Objects
below the
heater
Objects
below
the
heater
40”
(1 m)
MIN 30º
12” (30.4 cm)
MAX 60º
Greater than
or equal
to 6" (15.2cm)
Greater than
or equal
to 18" (45.7 cm)
Greater than
or equal
to 12" (30.4 cm)
Less than
6" (15.2cm)
6ft.
(183 cm)
8ft.
(244 cm)
6ft.
(183 cm)
8ft.
(244 cm)
FLOOR
FLOOR
1. The minimum installation height from the floor to the heater shall be:
6ft (183 cm) American Standard, 8ft (244 cm) Canadian Standard
2. The minimum clearances from the ceiling, walls and other objects are shown in the pictures below.
4. Building materials with low heat tolerance (i.e. plastics, vinyl siding, canvas, tri-ply, etc.) may be subject to degradation at
lower temperatures. It is the installer’s responsibility to ensure that adjacent materials are protected from deterioration.
Once the product is powered, it automatically goes into ON
mode. It will take a few minutes after powering on to reach
the maximum temperature.
Some parts of this product can become very hot and cause
burns. Particular attention has to be given where children
and vulnerable people are present.
Mounting Height / Clearances

10 www.InnovaHeatingCo.com
Ceiling Mount
30° 30°
Optional Chain Mounted
(not included)
Rotatable on both ends.
CEILING MOUNT APPLICATION
30°
45°
60°
EF39FMPFS - 39” FLUSH MOUNT FRAME*
43 3/4" x 12”
MINIMUM
5/8”
TYPE X DRY WALL
ONE HOUR FIRE-RATED
WHIP
Beam
Type X
5/8”
Drywall
Accessible
Junction
Box
Ceiling
Whip
WALL MOUNT APPLICATION
FLUSH MOUNT APPLICATION
Please reference FLUSH MOUNT KIT (MODEL#
EF39FMPFS/ EF39FMPFB) Instruction Manual for
Flush Mount application
Make sure heater is levelled during installation to
achieve equal heat distribution. Improper levelling
can cause shorter lifespan of the Quartz Element
* SOLD SEPARATELY
Ce manuel convient aux modèles suivants
3
Table des matières
Autres manuels Innova Chauffage
Manuels Chauffage populaires d'autres marques

oventrop
oventrop Regucor Series Manuel utilisateur

Blaze King
Blaze King CLARITY CL2118.IPI.1 Manuel utilisateur

ELMEKO
ELMEKO ML 150 Manuel utilisateur

BN Thermic
BN Thermic 830T Manuel utilisateur

KING
KING K Series Mode d’emploi

Empire Comfort Systems
Empire Comfort Systems RH-50-5 Guide de démarrage rapide

Empire Heating Systems
Empire Heating Systems WCC65 Manuel utilisateur

Wetekom
Wetekom 92 86 43 Manuel utilisateur

Desa
Desa SPC170-F Manuel utilisateur

Watlow
Watlow Watrod Electric Tubular Heaters Manuel utilisateur

Haverland
Haverland ECO-DRY GPS Series Manuel de la liste des pièces

Stelpro
Stelpro ASILVC2060 Series Manuel utilisateur