1.3 LEDs behaviour
LED POWER behaviour (power on device)
State Information
Red OK: Power supplied
Off Error : Power supply issue ¹
LED LAN behaviour (power on device)
State Information
Off There is no network traffic on the Ethernet connector
Blinking The blinking frequency is indicating the data rate on Ethernet connector
LED STATUS behaviour depending on device start-up steps
• Step 1 : Device start-up initialisation
State Information
Green: continuous OK
Always Off Error : Power supply issue ¹
• Step 2 : Device start-up finalisation
State Information
Off OK. This step duration can be from several seconds to several minutes.
Green blinking: 1 second duration flash and periodicity every 2 seconds Error: Boot issue ¹
• Step 3 : Nominal mode
State Information
Green blinking: 1 very short flash
(150 ms) and periodicity every 4
seconds
OK
Green blinking: 2 very short and
consecutive flashs (150 ms) and
periodicity every 4 seconds
Warning: Fail Soft Mode Level 1
De fréquents redémarrages de l'appareil ont été constatés (par exemple, 4 redémarrages en 10 minutes).
Un message est affiché à l'écran «Mode dégradé: attente d'un nouveau contenu».
L'instabilité a été causée probablement par un média de votre contenu qui n'est pas encore supporté par l'appareil. En
conséquence, pour prévenir de futur redémarrages inutiles, le contenu a été invalidé. Le message indique qu'une nouvelle
publication est requise pour jouer à nouveau le contenu. ²
Green blinking: 3 very short and
consecutive flashs (150 ms) and
periodicity every 4 seconds
Warning: Fail Soft Mode Level 2
De fréquents redémarrages de l'appareil ont été constatés (par exemple, 4 redémarrages en 10 minutes).
Un message est affiché à l'écran «Mode dégradé: attente d'un nouveau contenu».
Le contenu a été effacé et des valeurs de préférences utilisateur ont été restaurées. Le message indique qu'une nouvelle
publication est requise pour jouer à nouveau un contenu. ²
Green blinking: 4 very short and
consecutive flashs (150 ms) and
periodicity every 4 seconds
Warning: Check disk
The device has detected memory corruption on content storage. The media storage is being repaired. This repair step is
called Check-Disk and its duration can be several minutes. During this step, a message “checking the file system of data
partition in progress” is displayed on screen. ³
Green blinking: 5 very short and
consecutive flashs (150 ms) and
periodicity every 4 seconds
Warning: errors on system partition
The user has to connect to device WebUI, go to Maintenance > Tools menu, and press button Format or Repair to solve the
problem. ³
Green blinking: 6 very short and
consecutive flashs (150 ms) and
periodicity every 4 seconds
Warning: a firmware update is pending
During this phase, no content is played on the device, do not switch OFF the device.
Green blinking: 7 very short and
consecutive flashs (150 ms) and
periodicity every 4 seconds
Erro: write problem on the storage
For an unknown reason, your storage space isn't usable any more. ³
Off Error. ¹
¹ If the problem persists despite an appropriate power-supply, contact INNES technical support.