INIM Electronics SmartLink-P Instructions de montage

SmartLink-P
PSTN dialler
Installation and
programming
manual
PATENT PENDING

Installation and programming manual
2
Copyright
The information contained in this document is the sole property of
INIM Electronics s.r.l. No part may be copied without written
authorization from INIM Electronics s.r.l.
All rights reserved.
Directive 1999/5/CE (R&TTE) compliance.
Hereby INIM Electronics s.r.l. declares that SmartLink-P is in
compliance with the essential requirements and other relevant
provisions of Directive 1999/5/CE.
The full declarations of conformity of the above-mentioned devices
are available at URL: www.inim.biz/dc.html.

Installation and programming manual
3
Table of contents
Chapter 1 Introduction ...................................... 5
Chapter 2 General information ........................... 6
2.1 Manual details 6
2.2 Addressees 6
2.3 Software information 6
2.4 Intellectual property rights 6
2.5 Conventions 6
2.6 Manufacturer's name and address 7
2.7 Device identifier 8
2.8 Warranty 8
2.9 Safety laws 8
Chapter 3 Device management......................... 10
3.1 Transporting goods 10
3.2 Environmental conditions 10
3.3 Unpacking the device 10
Chapter 4 Technical description ........................ 12
4.1 Technical specifications 13
Chapter 5 Internal components ........................ 14
5.1 Terminal board 14
5.2 LED 15
Chapter 6 Device features ............................... 16
6.1 General features 16
6.2 Application 16
6.3 Intrusion control panel 16
6.4 Digital dialer (Contact ID) 17
6.5 Voice dialer 17
6.6 Remote control via DTMF 17
Chapter 7 Installation ..................................... 18
7.1 Installation instructions 18
7.2 Connections 19
Chapter 8 Settings.......................................... 21
8.1 Introduction 21
8.2 Installing the SmartLeague programming
software 21
8.3 SmartLeague software 22
8.4 Recommended programming flow 25
8.5 Set up referencing data 25
8.6 Setting up the SmartLink parameters 29
8.7 Programming the Inputs and Outputs —
IN&OUT 32

Installation and programming manual
4
8.8 Programming the SmartLink-P as an intru-
sion control panel 36
8.9 Programming event generated actions 37
8.10 Programming periodic events 44
8.11 Remote control of SmartLink-P via DTMF
tones 45
Appendix A Wiring diagram of an intrusion-control pan-
el ...................................................47
Appendix B Default settings................................49
Appendix C Order codes.....................................50
Notes: ............................................51

Installation and programming manual
Introduction 5
Chapter 1
Introduction
The SmartLink-P is a landline-phone dialer (PSTN).
It is capable of sending alarm reports (Contact ID protocol) over the landline
to Alarm Receiving Centres and customized voice-messages to contact
numbers.
This device greatly enhances the security of control panels which are not
equipped with built-in dialers. It can also be used to provide reduced -size
installations with all main functions of an intrusion-alarm reporting appliance.

Installation and programming manual
6General information
Chapter 2
General information
2.1 Manual details
Title: SmartLink-P Installation and Programming Manual
• Edition,Version: 1.00
• Month and Year of issue: December 2009
• Order code: DCMIINI0SLINKP
2.2 Addressees
•Installer
• Technical assistance
2.3 Software information
• SmartLeague software version: 3.x.x
• Firmware version: 2.x.x
2.4 Intellectual property rights
The information contained in this document is private property. All rights
reserved.
No part of this document may be copied or reproduced unless expressly
authorized in writing by INIM Electronics s.r.l., in particular the parts
regarding the device specified in 2.7 Device identifier.
INIM Electronics s.r.l. shall not be responsible for any damage arising from
improper application or use.
2.5 Conventions
2.5.1 Glossary and terminology
Device; apparatus: refers to the device defined in 2.7 Device identifier.
Left, right, behind, above, below: indications using the operator's position
in front of the mounted device as the reference point.
Pulse output: same as "monostable output"
Dialer (phone, digital):same as "communicator"
Qualified personnel
: those persons whose training, expertise and knowledge
of the respective laws and bylaws regarding service conditions and the

Installation and programming manual
General information 7
prevention of accidents, are able to identify and avoid all possible situations of
danger.
2.5.2 Graphic conventions
Text in italics: indicates the title of a chapter, section, paragraph, table or figure
in this manual or other published reference.
[Uppercase letters] (e.g.[A]): indicate the device parts
Note:
The detached notes contain important information about the
respective text.
Attention:
The attention prompts indicate that total or partial
disregard of the procedure could damage the connected
devices.
Danger:
The danger warnings indicate that total or partial
disregard of the procedure could injure the operator or
persons in the vicinity.
2.6 Manufacturer's name and address
INIM Electronics s.r.l.
Via Fosso Antico, Centobuchi
63033 Monteprandone (AP) - Italy
Tel: +39 0735 70 50 07
Tel: +39 0735 70 49 12

Installation and programming manual
8General information
2.7 Device identifier
Figure 1 - Overview
Product class: PSTN dialer
Model: SmartLink-P
Year of manufacture: 2009
2.8 Warranty
The manufacturer warrants the original purchaser that for a period of 24
months from the date of commissioning, the product shall be free of defects
in materials and workmanship. The warranty does not cover:
• Improper use or negligence
• Damage caused by fire, flood, wind, or lightning
•Vandalism
• Fair wear and tear
INIM Electronics s.r.l. shall, at its option, repair or replace any defective
products. Improper use, that is, use for purposes other than those mentioned
in this manual will void the warranty. For the full details and conditions
regarding the warranty, refer to the purchase order.
2.9 Safety laws
The aim of the instructions in this section is to ensure that the device is
installed and handled properly. This chapter contains vital information. The
installer should be familiar with this section and bring each item to the
attention of the system users.
Alimentazione / Power
LBDTIN4ASLINKP
I
-P
12/2009
Tension / Alimentacion
Consumo / Consumption
Consommation / Consumo
70 mA
13.8 V
Classe di Isolamento /
Insulation class
Insulation class / Clase aislante
MADE
IN
ITALY

Installation and programming manual
General information 9
2.9.1 Managing electronic devices
The normal motions of any person may generate electrostatic potential of
thousands of volts. Discharge of this current through semiconductor devices
during handling may cause serious damage which although may not be
immediately evident may reduce the reliability of the circuits.
If located in their housings, the electronic circuits of INIM Electronics s.r.l.
products are highly immune to electrostatic discharge.
Do not expose the circuits to damage by removing the modules unnecessarily
from their housings.
1. When removing or handling the boards, hold the board edges only.
2. Do not touch the electronic components, the printed circuits or the metal
parts of the connectors.
3. Do not hand the module to another person without first ensuring that
you both have the same electrostatic potential. This can be obtained by
simply shaking hands.
4. Place the module on an anti-static surface or a conductor surface with
the same potential.
Further information regarding safe working procedures with electronic
appliances can be found under: IEC 61340-5-1 ed IEC/TR 61340-5-2.
2.9.2 Setting up the system
In order to provide adequate protection and instructions for proper use,
security professionals (Installers and maintenance/test technicians) must be
familiar with the operating procedure of this device.
Please read the instructions carefully before installing and/or servicing the
system.
Before first power-up, be sure that the earth connection has been completed
properly on the respective terminal.
The recommended minimum wire cross section for the earth connection is
2.5 mm2, that is, unless expressly stated in the additional documentation.
2.9.3 Replacement and disposal of used devices
Replacement
When replacing used devices, disconnect the devices concerned then
complete the connections of the replacement devices in compliance with the
instructions printed on the respective inserts.
Contact your local municipal offices for information regarding the disposal of
used electronic devices.
Disposal
Do not burn used electronic devices, or allow them to pollute the
environment (countryside, rivers, etc.). Electronic devices must be disposed
of in a safe environment-friendly way. In order to avoid short-circuits, take
all the necessary precautions when removing used batteries. Contact your
local municipal offices for information regarding the disposal of batteries.

Installation and programming manual
10 Device management
Chapter 3
Device management
3.1 Transporting goods
The individual devices are properly packed in cardboard boxes and
transported in extra-strong cartons. However, during storage and handling,
special care must be taken to avoid accidental damage (knocks and falls) and
to protect the boxed device from extreme heat and/or cold.
3.2 Environmental conditions
Temperature limits
-10° / +55°C for transport and storage
+5° / +40°C operating temperature
3.3 Unpacking the device
The goods must be unpacked with care. All waste packaging materials must
be disposed of in compliance with the local laws and bylaws in force.
The device is packed in a cardboard box.
Note:
The 1.2 A/h battery is not included. Ensure you have the
battery on hand before starting.
Inside the box:
• SmartLink-P PCB mounted on one metal and three plastic supports
• The meta box contains:
- 10 resistors @ 15kohm
- 4 frontplate screws
The following accessory items must be ordered separately (see Appendix C
for the order codes):
• SmartLogos60 voice board
• Switching power supply/battery charger (13.8V 1A IPS12015DT)
Table des matières
Autres manuels INIM Electronics Système de conférence
Manuels Système de conférence populaires d'autres marques

Kramer
Kramer VIA GO Manuel utilisateur

AVT
AVT MAGIC AC1 Go Manuel utilisateur

ProSoft Technology
ProSoft Technology AN-X4-AB-DHRIO Manuel utilisateur

Sony
Sony PCS-I150 Manuel utilisateur

Middle Atlantic Products
Middle Atlantic Products VTC Series Manuel utilisateur

Prentke Romich Company
Prentke Romich Company Vanguard Plus Mode d’emploi