INHENERGY SI 50K Manuel utilisateur

INHENERGY CO., LTD.
User Manual
SI 50K, SI 60K, SI 70K, SI 80K

-1-
CONTENTS
1 NOTES ON THIS MANUAL.......................................................................................................- 3 -
1.1 VALIDITY.................................................................................................................................. - 3 -
1.2 SYMBOLS IN THIS DOCUMENT.........................................................................................- 3 -
2 OVERVIEW.....................................................................................................................................- 4 -
2.1 PRODUCT INTRODUCTION................................................................................................ - 4 -
2.2 APPEARANCE......................................................................................................................... - 5 -
3 INSTALLATION.............................................................................................................................- 6 -
3.1 CHECK FOR PHYSICAL DAMAGE...................................................................................... - 6 -
3.2 PACKING LIST......................................................................................................................... - 6 -
3.3 MOUNTING.............................................................................................................................- 7 -
3.4 SPACE REQUIREMENT..........................................................................................................- 9 -
3.5 MOUNTING STEPS................................................................................................................- 9 -
4 ELECTRICAL CONNECTION...................................................................................................- 10 -
4.1GRID CONNECTION............................................................................................................ - 10 -
4.2 PV CONNECTION................................................................................................................- 11 -
4.3 485 CONNECTION..............................................................................................................- 13 -
4.4 TURN-OFF THE INVERTER................................................................................................ - 14 -
5 POWERING ON THE SYSTEM...............................................................................................- 14 -
5.1 START-UP THE INVERTER................................................................................................. - 14 -
5.2 FIRST RUN TIME SETTING................................................................................................ - 14 -
6 LCD OPERATION....................................................................................................................... - 14 -
7 MAINTENANCE AND CLEANING....................................................................................... - 16 -
7.1 MAINTAIN PERIODICALLY................................................................................................ - 16 -
7.2 TROUBLE SHOOTING.........................................................................................................- 16 -

User Manual
-2-
8 DECOMMISSIONING...............................................................................................................- 16 -
8.1 REMOVE THE INVERTER....................................................................................................- 18 -
8.2 PACKAGING.......................................................................................................................... - 18 -
8.3 STORAGE AND TRANSPORTATION................................................................................- 18 -
9 TECHNICAL DATA.....................................................................................................................- 18 -
10 MANUFACTURER WARRANTY..........................................................................................- 18 -
11 CONTACT.................................................................................................................................. - 20 -

-3-
1 Notes on this manual
1.1 Validity
This manual describes the assembly, installation, commissioning and maintenance of
the following Inhenergy Inverter model:
SI 50K
SI 60K
SI 70K
SI 80K
Target Group
This manual is for qualified personnel. Qualified personnel have received training and
have demonstrated skills and knowledge in the construction and operation of this
device. Qualified Personnel are trained to deal with the dangers and hazards involved in
installing electric devices.
Additional information
Find further information on special topics in the download area at www.inhenergy.com
The manual and other documents must be stored in a convenient place and be available
at all times. We assume no liability for any damage caused by failure to observe these
instructions. For possible changes in this manual, Inhenergy Co., Ltd. accepts no
responsibilities to inform the users.
1.2 Symbols in this document
Please pay close attention to all the symbols for the purpose of avoiding possible personal
injury or equipment break down.
Symbol
description
DANGER indicates a hazardous situation which, if not
avoided, will result in death or serious injury.
WARNING indicates a hazardous situation which, if not
avoided, could result in death or serious injury.

User Manual
-4-
Markings on this product
2 Overview
2.1 Product Introduction
Function
CAUTION indicates a hazardous situation which, if not
avoided, could result in minor or moderate injury.
NOTICE is used to address practices not related to personal
injury
Information that you must read and know to ensure
optimal operation of the system.
Symbol
Explanation
Caution,risk of electric shock
Caution,hot surface
Operation after 5 minutes
Read the manual
Point of connection for grounding protection
CE mark.
The inverter complies with the requirements of the
applicable CE guidelines.
The inverter must not be disposed of with the household
waste.

User Manual
-5-
The Inverters is a three-phase grid-tied PV string inverter that converts the DC power
generated by PV strings into AC power and feeds the power into the power grid.
Models
This document involves the following product models:
SI 50K,SI 60,SI 70K,SI 80K;
Model description (,SI 80K is used as an example)
Model description
2.2 Appearance
1.LED indicator 2. LCD display 3. Function button 4. DC switch
5.DC input terminals (PV1) 6. DC input terminals (PV2) 7. DC input terminals (PV3)
8. DC input terminals (PV4) 9. GPRS/WIFI output port 10.Communication port (RS485)
11. AC output port
Icon
Meaning
Description
1
Product
the grid-tied PV string inverter
2
Power level
50K :The rated power is 50 kW.
60K :The rated power is 60 kW.
70K :The rated power is 70 kW.
80K :The rated power is 70 kW.

User Manual
-6-
LED indicator description
Function button description
3 Installation
3.1 Check for Physical Damage
Make sure the inverter is intact during transportation. If there is any visible damage,
such as cracks, please contact your dealer immediately.
3.2 Packing List
Open the package and take out the product, please check the accessories first.
The packing list shown as below.
Category
Status
Meaning
Blinking green at short intervals
waiting status
Blinking green at long intervals
Self-check
Steady green
normal status
Steady yellow
Alarm
Off
No alarm
Blinking red at short intervals
Fault
Off
faultless
Category
Description
ESC button: Return from current interface or function.
Down button: Move cursor to downside or decrease
value
Up button: Move cursor to upside or increase value.
OK button: Confirm the selection.

User Manual
-7-
*C : SI 50K PV connectors (9*positive,9*negative);
SI 60K /70K PV connectors (12*positive,12*negative);
SI 80K PV connectors (16*positive,16*negative);
*D: SI 50K PV pin connectors (5*positive,5*negative);
SI 60K /70K PV pin connectors (12*positive,12*negative);
SI80K PV connectors (16*positive,16*negative);
3.3 Mounting
Installation Precaution
SI 80K series inverter is designed for outdoor installation (IP 65).
Make sure the installation site meets the following conditions:
Object
Description
Quantity
A
Inverter
1
B
Bracket
1
*C
PV connectors (16*positive,16*negative)
16/16
*D
PV pin connectors (16*positive, 16*negative)
16/16
E
Ring terminal
6
F
User manual
1
G
Expansion screws
5
H
Set screw( for mounting,external enclosure grounding)
3
I
Cable gland for AC connection
1
J
RS485 terminal (optional)
1
K
Wifi module (optional)
1

User Manual
-8-
◆ Not in direct sunlight.
◆ Not in areas where highly flammable materials are stored.
◆ Not in potential explosive areas.
◆ Not in the cool air directly.
◆ Not in environment of precipitation or humidity (>95%).
◆ Under good ventilation condition.
◆ The ambient temperature in the range of -20℃ to +60℃.
◆ The wall hanging the inverter should meet conditions below:
1.Solid brick/concrete, or strength equivalent mounting surface;
2.Inverter must be supported or strengthened if the wall’s strength isn’t enough(such
as wooden wall, the wall covered by thick layer of decoration).
Please avoide direct sunlight, rain exposure, snow laying up during.
◆ The slope of the wall should be within 80°.

User Manual
-9-
3.4 Space Requirement
3.5 Mounting Steps
1.Use the wall bracket as a template to mark the position of the 5holes on the wall.
2.Drill holes with driller, make sure the holes are deep enough (at least 75mm) for
installation, and then tighten the expansion tubes.
3. Install the expansion tubes in the holes, and tighten them. Then install the wall
bracket by using the expansion screws.(Φ10 driller, torque: 2.5±0.2Nm)
4. Hang the inverter over the bracket, move the inverter close to it, slightly lay down the
inverter, and make sure the 4 mounting bars on the back are fixed well with the 4
grooves on the bracket.
5.After confirming the inverter is fixed reliably, fasten two M5 safety-lock sockets head
cap screws on the right or left side firmly to prevent the inverter from being lifted off the
bracket (torque: 2.0±0.2Nm)
Ce manuel convient aux modèles suivants
3
Table des matières
Autres manuels INHENERGY Onduleur

INHENERGY
INHENERGY SI-33K-T2 Manuel utilisateur

INHENERGY
INHENERGY SI-7K-S2 Manuel utilisateur

INHENERGY
INHENERGY HI-3K-SL Manuel utilisateur

INHENERGY
INHENERGY HI-3K-SL Manuel utilisateur

INHENERGY
INHENERGY SI-4K-T2 Manuel utilisateur

INHENERGY
INHENERGY SI-3.6K-S2 Manuel utilisateur

INHENERGY
INHENERGY NI-5048M-HF Manuel utilisateur