This technical manual has been developed to pro-
vide the necessary assistance in the installation to
those companies that held the BUSing®Partner o
are BUSing®Installer certify and who also work with
INGENIUM's BUSing® Communications Equipment.
• The BUSing® Certificates are obtained by taking train-
ing courses that IN ENIUM organizes periodically.
• For more information contact us:
In the following pages you will fin detailed charac-
teristics and techniques, a brief description and a
connection sketch for INGENIUM’s equipment.
• The end of the manual shows examples of different
types of installations: centralized, distributed, mixed,
prolonged and extended; besides several integrations
schemes with devices from other companies.
• It also includes information on programming software
developed by IN ENIUM, the BUSing® Development
System (SIDE), as well as the APPs to control BUSing®
installations.
Ingenium is a vanguard company dedicated since
1998 to the design, development and manufactur-
ing of the highest domotics technology.
From the beginning we have been conscious of
the necessity to approach this emergent market
with high standards of quality and focusing on
R&D. This allows us to innovate without neglect-
ing the manufacturing process while making us
confident of our effort. Our focus causes that
every year more people approach our system.
Our system BUSing® totally open and free of royal-
ties, allows other manufacturers to design equip-
ment under our standards and specifications, as
well as the development of integrations on other
devices or gateway with other standards.
Our products are versatile and intuitive, guaran-
teeing comfort, security and energy efficiency
without forgetting design; basic pillars on which
our concept of domotics is founded. This is how
we elaborate our catalogue.
• It is strictly recommended to use shielded and flexible
cable for the wiring of the data BUS (Cable BUSing®).
• In no case should be used the power wiring pipes for
wiring BUS or inputs signals, because it is SELV signals.
• Ingenium is not responsible for the improper function-
ing of the system in the case of making a star-wiring
BUS. It is recommended that BUS topology is used.
• The number of required power supplies can vary de-
pending on wiring distances between devices and the
installation in general.
• Ingenium always recommend the use of protection,
both in electrical line and telephone line, to prevent
possible damage by power surges.
• To ensure the proper functioning of communications,
especially in electrically noisy installations, an End-
BUS device must be placed in the beginning and an-
other one at the end of the bus line.
• The system is virtually unlimited, and can count up to
255 devices or nodes per line, up to 255 lines. It rep-
resents more than 65,000 devices with more than
300,000 outputs in the same installation.
• It is fully scalable and new devices can be always
added in an already existing installation. Installed de-
vices can be also reprogrammed at any time.
• The communications protocol, BUSing®, can be wired
(4-wire BUS) or wireless (868 MHz frequency, grouped
in our WIN S-RF trademark).
Both types can coexist in the same installation estab-
lishing communications between different ways of
communication.
• Both the programming and implementation must be
carried out exclusively by installers / integrators who
are certified BUSing®.
BUSing® General Requirements
introduction