Safety Information
WARNING!
Read the safety precautions in this section before installing,
powering, operating or servicing this product.
Read this manual before installing, powering or servicing this product. Follow the safety precautions
listed below and observe all warnings in this manual and pay attention to the warnings printed on the
product.
If you have questions about how to operate the panel safely, please contact your INFiLED supplier.
The following symbols are used to identify important safety information on the product and in this
manual.
PROTECTION FROM ELECTRIC SHOCK
•The product must be powered with AC power within the range of 100 – 240 V
nominal at 50/ 60 Hz only.
•Disconnect the entire installation from power before carrying put installation or
maintenance work. Make sure the power cannot be reconnected, even by
accident.
•Double-pole/neutral fusing is used. If the installation is not completely
disconnected from power, parts may remain live even if one of the two mains
fuses has blown.
•When not in use, the product should be disconnected.
•Always ground (earth) the product electrically.
•Use only a source of power that complies with local building and electrical codes
and has both overload and ground (earth) -fault protection.
•Connect the Header to power using only the cables supplied by INFiLED for this
product.
•Protect power cables from water and rain.
•Connect the Header to power using only 32 amp-rated industrial Type B power
plugs and socket outlets that comply with IEC 60309 (or a comparable national
standard) and provide an electrical connection to ground (protective earth).
•External power switches or socket outlets used to supply Headers with power must
be located near the product and easily accessible so that the product can easily be
disconnected from power.
•Do not connect any other device than Wallpaper series panels to the power
throughput connector in the base of the product.
•Connect no more than seventeen Wallpaper panels in total to one main power
cable
•Before using the product, check that all power distribution equipment and cables
are in perfect condition and rated for the current requirements of all connected
devices.
•Do not use the product if the power cable or a power plug is in any way damaged,
defect or showing signs of overheating.
•Do not attempt to open any cover.
•Refer any service operation not described in this manual to a qualified technician.
2019
INFiLED Wallpaper User’s manual

3
Safety Information
PROTECTION FROM FIRE
•Provide a minimum clearance of 8.5 cm (0.39 in) around the cover at the back
of the panel base.
•Do not stick filters, masks or other materials directly onto LED modules.
•Do not modify the product in any way not described in this manual.
•Install only genuine INFiLED parts in or on the product unless an alternative is
described in this manual.
•Do not operate the product if the ambient temperature exceeds 40° C (104° F).
PROTECTION FROM INJURY
•Ensure that any structure used for support as well as all fastening and
connecting hardware can hold at least 10 times the weight of all supported
devices and equipment.
•Do not suspend panels using any other method of attachment than those
described in this manual.
•Create an installation by installing panels starting from the top and working
downwards. Disassemble an installation by removing panels at the bottom and
working upwards.
•Check that all external covers and rigging hardware are securely fastened.
•Block access below the work area and work from a stable platform whenever
installing, servicing or moving the product.
•Do not look at lit LEDs from a distance less than 40 cm (1 ft. 4 in.) without
suitable protective eyewear.
•Do not view lit LEDs with optical instruments that may concentrate the light
output.
2019
INFiLED Wallpaper User’s manual

CONTENT
4
SAFETY INFORMATION
1. PRODUCT OVERVIEW
1.1 FEATURES 5
1.2 DIMENSIONS 6
1.3 EXTERNAL COMPONENTS 7
1.4 SPECIFICATIONS 8
1.5 PACKAGE 9
2. MECHANICAL INSTALLATION
2.1 VERTICAL CONNECTION 10
2.2 HORIZONTAL CONNECTION 12
2.3 INSTALLATION COMPONENTS 13
2.4 SMALL SCREEN INSTALLATION 16
2.5 BIG SCREEN INSTALLATION 17
2.6 LED-PANEL SUSPENSION 18
3. POWER AND DATA CONNECTION
3.1 ELECTRICAL COMPONENTS 19
3.2 POWER AND DATA LINK 20
4. SOFTWARE
4.1 SENDERBOARD 23
4.2 HARDWARE CONNECTION 24
4.3 SOFTWARE INTRODUCTION 25
5. SERVICE AND MAINTENANCE
5.1 MAINTENANCE ANNOUNCEMENT 32
5.2 TEST BUTTON AND INDICATOR LEDs 33
5.3 TROUBLESHOOTING 34
5.4 SERVICE DESK 35
2019
INFiLED Wallpaper User’s manual

The ultra-thin wallpaper series can be fixed closely onto the wall and achieves
to save as much space as it can with its 29.5 millimetre thickness. Front
installation and maintenance is affordable for an easy operation and neat
environment. With its 16:9 panel ratio and narrow pixel pitch, the wallpaper
could easily build 2K and 4K screens. Seamless connection and high definition
solution ensure perfect visual effect of images and videos.
The recessed power and data connector provide an integrated cable-free
interlink. The wallpaper can be controlled independently when its off-line due
to the available USB Data option.
5
1. Product Overview
1.1 Features
2019
INFiLED Wallpaper User’s manual

6
1. Product Overview
1.2 Dimensions
2019
INFiLED Wallpaper User’s manual
Cabinet height: 337,5 mm (13,29 in)
Cabinet width: 600 mm (23,62 in)
Cabinet depth: 29 mm (1,14 in)
Weight: 6 kg (13,23 lb)

7
1. Product Overview
1.3 External Components
2019
INFiLED Wallpaper User’s manual
Pos. Name Note
1 Position pin Easy cabinet alignment
2 Vertical “Rolling”- Lock Mechanical connection to upper panel
3 Cable-free power socket Recessed power socket
4 Hanging pin Hanging point for fixed installation (4x)
5 Horizontal “Fast”- Lock Mechanical connection to lateral panel
6 Data socket Socket for data input
7 Power socket Socket for power supply
8Cable-free power
connection Recessed plug for power interlink
9 Power connection Additional power socket
10 Data connection Socket for data interlink
1 2 3 4
5
6
7
8
9
10

8
1. Product Overview
1.4 Specifications
2019
INFiLED Wallpaper User’s manual
Modul Number IL-RSS-IRWP 1.2
Pixel Pitch 1,25 mm
Physical Density 640.000 pixel/m²
LED Arrangement 3in1 SMD
Module Resolution 240 x 135 pixels
Module Dimensions 300 x 168,75mm (11,81 x 6,64 in)
Cabinet Resolution 480 x 270 pixels
Cabinet Dimensions 600 x 337,5 x 29 mm (23,62 x 13,29 x 1,14 in)
Cabinet Weight 5.2 kg (11.46 lb)
Brightness 600 ~ 800 cd/m²
Max. Power Consumption 180 W/m²
Ave. Power Consumption 60 W/m²
Visual View Angel 160° / 160°
Operating Power Source 100 - 240 V, 50 - 60 Hz
Operating Temperature -10 °C - +45 °C
Refresh Rate ≤ 3.840 Hz
Life Span 100.000 h
MTBF 5.000 h
IP Rating IP30
Max. Rigging 17 cabinets
Signal Input Source Composite s-video, Component, VGA, DVI, HDMI, SDI,
HD-SDI
Verification CE, RoHs, ETL, FCC

9
1. Product Overview
1.5 Package
Pack the cabinets in INFiLED Wallpaper Series flight case for transportation.
This will provide protection against the physical damage during transportation
or storage. Ensure all flight cases are transported or stored in upright position.
To reduce the impact of vibration in transit, please package the cabinets using
the EPE foam provided.
Any damage sustained by incorrect packaging or storage is not within the
scope of warranty!
Notifications for packing and storage:
•Always dry the panels before packing or storage
•Make sure the cabinet or flight case doesn’t show any signs of damage
•Look the case as soon as all cabinets, which need to be stored, are inside
•When the cases are stacked, make sure the wheels are looked and in the
wheel recesses of the case below
•Carry the flight case by an suitable forklift and take safeguard procedures to
avoid injury if necessary
•Prior to normal operation, please allow long- term stored displays two hours
of warming at 50% brightness, followed by two hours of warming at 100%
brightness level
2019
INFiLED Wallpaper User’s manual

The mechanical connection between Wallpaper panels is fastened by rolling-locks. Position
pins helping to align the cabinets correctly. The supplied Allen key is required for turning the
lock into the fastened position.
There are two different ways for the vertical panel attachment. Which method must be used
depends on the rear service possibility. If only front service is available due to narrow or no
space behind the screen installation, LED modules must be taken out in order access the
locking system from the front.
10
2. Mechanical Installation
2.1 Vertical Connection
Back-mounted
1. The lock is in open position when the
hock is recessed in the frame, ensure
that this position is applied.
2. Align the panels carefully.
3. Insert the supplied Allen key or use
another suitable one.
4. Turn the key counter-clockwise to secure
the lock. The lock must be rotated till
the stopping point is reached.
2019
INFiLED Wallpaper User’s manual
Ce manuel convient aux modèles suivants