10 11
Fault Finding
In the unlikely event of a fault, please consult the following table:
Display What it means Necessary action Likely causes
No Pan
Present
There is no pan on
the ring
Place a suitable pan on the hob Either no pan is present on the hob,
the pan is smaller than the inner ring
on the hob surface, or the pan is not
suitable for induction.
Clean filter The inside of the
hob is too hot
Turn knob fully anticlockwise
to ‘--’ and leave for 10 mins.
Turn hob on again
Check that air filter is clean -
see 6. above
Check that fan is working
Glass is hot The glass is over
80°C
The glass immediately under the
pan will become hot during use
This is a safety notice and
NOT A FAULT.
Shut down The hob has
sensed an
unusual condition
Turn knob full anti-clockwise
to ‘--’, then slowly back to its
original setting
There will be an error code number
in the power setting display –
see below
Glass is hot/
Shutdown
(alternating)
The hob has
detected an
unacceptably
high internal
temperature
Caution - the top may be very hot.
Remove the pan. Turn the hob
power setting to 0 and leave it
to cool for ten minutes. (The hob
should still be switched on to allow
the fan to cool the unit) Switch the
hob to the -- power setting (the fan
will switch o) and then resume
normal operation.
All Digits
Flashing
(CS3000/1G
CS3000/1QB
CS3000/1QT
only)
Lid safety inhibitor
activated
Push lid securely back into place Lid disengaged during filter cleaning.
See Section 6 above.
01 Mains voltage error Turn the knob full anti-clockwise,
and then advance it clockwise
High or low mains voltage - electrical
supply requires investigation.
02 Electronic overload Turn knob fully anti-clockwise
to ‘--’, then slowly back to its
original setting
May happen infrequently in
normal use. Try a dierent pan.
03 Electronics
Overtemp
Turn knob fully anti-clockwise
to ‘--’, then slowly back to its
original setting
Probable cause is a blocked air filter.
Clean the filter - see section 6
04 Coil Overtemp Turn knob fully anti-clockwise
to ‘--’, then slowly back to its
original setting
Extended use of a griddle or wok can
cause this. Alternatively a blocked air
filter – see section 6
05 Electronic sensor
malfunction
Turn knob fully anti-clockwise
to ‘--’, then slowly back to its
original setting
If re-setting does not clear the
indication, the hob must be returned
for repair.
06 Coil sensor
malfunction
Turn knob fully anti-clockwise
to ‘--’, then slowly back to its
original setting
If re-setting does not clear the
indication, the hob must be returned
for repair.
Information on appliances where product labels are
hidden after installation, see below.
‘PAT Testing (Single phase hob products)
This equipment has been factory tested in accordance with the recommendations of BS3456:
parts 201 and 202, with regard to insulation resistance and earth continuity.
The equipment has been fitted with surge protection on the AC mains input to conform to CE/UKCA
requirements. As a result, Y capacitors C18 and C19 will return a fail value of approximately 6.5mA
during the Sub leakage test. You will be required to either remove C18 and C19 temporarily, prior to PAT
testing (and if you choose this option, it is important that you replace the capacitors after test as they
are for the protection of the operator and equipment). Or the second option is to increase the sub
leakage PASS value to 7mA on the PAT tester.
Please contact Induced Energy Ltd (01280 875400) for detailed information on this procedure.
Product Code CS3000DB
Rated Power Input 3.0 kW 13A
Rate voltage 230 V AC nom
Rated Frequency 50 Hz
ISM Equipment Group 1
Operating Frequency 25kHz
Weight 9.5 kg
IP Rating 52
Product Code CS3000DF(P)
Rated Power Input 3.0 kW 13A
Rate voltage 230 V AC nom
Rated Frequency 50 Hz
ISM Equipment Group 1
Operating Frequency 25kHz
Weight 9.5 kg
IP Rating 52
Product Code CS3000DF-PSCH(U)
Rated Power Input 3.0 kW 13A
Rate voltage 230 V AC nom
Rated Frequency 50 - 60Hz
ISM Equipment Group 1
Operating Frequency 25kHz
Weight 10 kg
IP Rating 52
Product Code CS3000GB-1
Rated Power Input 6.0 kW 32A
Rate voltage 230 V AC nom
Rated Frequency 50 Hz
ISM Equipment Group 1
Operating Frequency 25kHz
Weight 30 kg
IP Rating 52
Product Code CS3000GB-2
Rated Power Input 2 x 3kW 13A
Rate voltage 230 V AC nom
Rated Frequency 50 Hz
ISM Equipment Group 1
Operating Frequency 25kHz
Weight 30 kg
IP Rating 52
Product Code CS3000GB-3
Rated Power Input 6.0kW 32A
Rate voltage 415V AC nom
Rated Frequency 50 Hz
ISM Equipment Group 1
Operating Frequency 25kHz
Weight 30 kg
IP Rating 52
Product Code CS3000KH(P
Rated Power Input 0.8 kW 13A
Rate voltage 230 V AC nom
Rated Frequency 50 Hz
ISM Equipment Group 1
Operating Frequency 25kHz
Weight 10 kg
IP Rating 52
Product Code CS3000QB
Rated Power Input 12.0 kW 32A
Rate voltage 415 V AC nom 3 Phase
Rated Frequency 50 Hz
ISM Equipment Group 1
Operating Frequency 25kHz
Weight 60 kg
IP Rating 52
Product Code CS3000QB(U)
Rated Power Input 12.0 kW 32A
Rate voltage 415 V AC nom 3 Phase
Rated Frequency 50 -60 Hz
ISM Equipment Group 1
Operating Frequency 25kHz
Weight 60 kg
IP Rating 52
Product Code CS3000QB-1
Rated Power Input 2 x 6.0kW 32A
Rate voltage 230 V AC nom
Rated Frequency 50 Hz
ISM Equipment Group 1
Operating Frequency 25kHz
Weight 60 kg
IP Rating 52