Impromat Klima UTI-IQCP Manuel utilisateur

User Guide
UTI-IQCP
Control panel for setting
and monitoring of UTI-INV internal
temperature regulator
v. 1.06 EN

1. MAIN DISPLAY SCREEN
Status of the device:
Error - call the service!
The device operates in heating mode
The device operates in cooling mode
Defrosting of outdoor unit in progress
The device is switched off
Water heating in progress
Water heating with first stage of bivalent activated
Water heating with first and second stage of bivalent activated
Summer mode is activated (only HDW heating)
HDW heating in progress
HDW heating using electric heating in progress
The device is in reduced mode
The device is in high tariff operation (rate)
Current time and date
HDW tank
temperature
Settings
Outdoor temperature
Indoor temperature
Current status of the device
Output water
temperature
The main display screen is divided into five basic monitoring windows and buttons serving to enter the
devices setting menu.
1

Setting options:
Control (ON/OFF, Cooling/Heating, Summer/Winter)
Parameters setting (temperature sensors, operation limits, equitherm regulation etc.)
Reduction timer
Temperature sensors
Device information
Current time and date
Language
Network setting
Sound setting
Backlight
UTI-INV module
settings
Back to the main screen
UTI-IQCP control panel
settings
2. SETTINGS
The Settings menu is divided into two rows of icons. The top row icons are used for the control of the
UTI-INV module (mode, equitherm regulation, HDW etc.), the bottom row icons are used to set the
UTI-IQCP control panel (language, time, network connection etc.).
2

Status icons:
The device is OFF
The device is ON
The device is Cooling mode
The device is Heating mode
The device is Winter mode
The device is Summer mode
Back
ON/OFF
Mode setting
Season setting
2.1 Basic control
The control screen allows the setting of the devices main modes. The icons on the left show the
current status.
There are three basic parameters:
On / Off - Turns the device on or off. In the ON state, all set programmes are running. In the OFF state,
the divice does not perform any action. It is possible that after swiching the device off, the circulation
pump might still be running for a while.
Heating / Cooling - In the heating mode, the device heats according to the heating curve, and heats
the domestic hot water. In the cooling mode, the device cools the water at a preset temperature, the
HDW heating is not activated.
Summer / Winter - Choosing the season. In summer mode, the device only heats the HDW tank. In
winter mode, all heating operations are performed.
3

Parameters in view mode:
Parameters in edit mode:
Moving up and down
between parameters
Current value
Edited value
Back to the Settings
Current value
New value
(select to edit)
2.2 Parameters settings
The menu with a number of parameters that can be viewed, and modified, if necessary. The current
value of the parameter is displayed. If the parameter is user-editable, a box labelled New is
displayed.
Parameters that cannot be edited:
- Mode V2
- Maximum temperature of the refrigerant in the heating mode
- Minimum temperature of the refrigerant in the cooling mode
- Mode V1
4
Changing the value
up and down
Save and return to
the Settings menu

Editable parameters:
- Time limit - supply water - time during which the HDW tank will be heated.
- Temperature reduction - cooling - how many degrees will the temperature increase in the
cooling mode.
- Temperature reduction - heating - how many degrees will the temperature decrease in the
heating mode.
- Bivalent temperature - outdoor temperature that causes the outdoor unit shutdown.
- Cooling water temperature - requied water temperature in the cooling mode.
- Power limit - cooling - maximum capacity of the outdoor unit during cooling mode.
- Power limit - heating - maximum capacity of the outdoor unit during heating mode.
- Max. temperature - supply water - maximum temperature in the HDW tank.
- Min. temperature - supply water - minimum temperature in the HDW tank.
- Power limit - supply water - maximum capacity of the outdoor unit during HDW heating.
- Heating water (outdoor +20°) - required heating water temperature at +20°C outdoor temp.
- Heating water (outdoor +12°) - required heating water temperature at +12°C outdoor temp.
- Heating water (outdoor +4°) - required heating water temperature at +4°C outdoor temp.
- Heating water (outdoor -4°) - required heating water temperature at -4°C outdoor temp.
- Heating water (outdoor -12°) - required heating water temperature at -12°C outdoor temp.
- Heating water (outdoor -20°) - required heating water temperature at -20°C outdoor temp.
- Regulation constant - value affecting the communication speed with the outdoor unit.
- Indoor temperature limit - heating - maximum indoor temperature in the heating mode.
- Indoor temperature limit - cooling - minimum indoor temperature in the cooling mode.
Required water
temperature according
to the equitherm curve
Back to Settings
Exchanger temperature
Other sensors
2.3 Temperature
List of other temperature sensors that are not shown on the main screen. The exchanger temperature
and the required temperature are displayed. The E, F and G sensors are displyed - these values are only
informative and do not affect the regulation.
5

For each day of the week, you can select up to four time intervals during which the reductution timer is
active. Move between the days of the week using the arrow buttons. To set the time, click on the
corresponding box and insert the value using the arrow buttons.
Set time intervals
Time interval is not set
Edited value
2.4 Reduction timer
Moving between days of the week:
Setting the time intervals:
6
Changing the time
10 minutes up/down
Moving up and down
between days
Back to the Settings
Save and return to
the Settings menu

Information sheet showing the current version of the control panel, type of the outdoor unit and
other information, including the MAC address of the device (if you are incorporating the panel to the
network). The last line shows if the SD card is inserted.
2.5 Device information
Compatible units:
- AOY
- AOYR
- AOYA
- AOYD
- HP
- AOYG-mmcc (model, capacity)
Language options
The UTI-IQCP control panel offers three language versions. When you select the language, the user
interface will switch to that language. By pressing the Back button, the setting will be saved and the
screen will return to the Settings menu.
2.6 Language setting
7
Back to the Settings
Save and return to
the Settings menu

No function assigned
Back
To set the current date or time, highlight the item you want to edit. The value can then be changed
using the up and down arrows. By pressing the Back button, the setting will be saved and the screen
will return to the Settings menu.
2.7 Current date and time
8
Changing the value
up and down
Date and time in view mode:
Date and time in edit mode:
Save and return to
the Settings menu

DHCP deactivated:
It is possible to set the IP address, subnet mask and gateway of the network so that the devices can be
connected to the network. If the installation permits, it is possible to activate the DHCP server.
2.8 Network setting
Note: If you dont know what value to set, do not make any changes, or connect the panel to the
network. Please consult your network administrator.
To set the desired value, click on the item you want to edit. The value can be changed using the up and
down arrows. By pressing the Back button, the setting will be saved and the screen will return to the
Settings menu.
9
Changing the value
up and down
DHCP activated:
Save and return to
the Settings menu