Ilsintech Keyman S1 Manuel utilisateur

Instruction manual
Optical fiber fusion splicer
Keyman S1
Please read through this manual completely
before its first use.

1
I. Safety guide
II. Product structure
1. Parts of the splicer
2. Requirements for splicing
III. Product guide
1. Outward of the main body
2. Parts for fusion splicing
IV. Using method
1. Power supply
V. Instructions for use
1. Function keys
2. Turning on S1
4. Cleaning optical fibers
5. Inserting optical fibers into protection sleeves
6. Cleaning and stripping optical fibers
7. Cleaving bare optical fibers
8. Placing the fiber in the splicer
9. Splicing procedures
10. Removing spliced optical fibers
11. Installing the protection sleeve in the sleeve heater
12. Heating the protection sleeve
VI. The maintenance of quality splice
1. Cleaning and inspection before splicing
2. Regular inspection and cleaning
VII. Main Menu
1. Select Splice Mode
3. Installing the protection sleeve lauder
Contents
4
8
8
9
10
1
12
13
13
17
17
18
29
19
20
20
20
21
22
27
27
28
29
31
34
10
34
19

2
2. Select Heater Mode
3. Arc calibration
5. Splice Memory
VIII. Sub Menu
1. Language
2. Power Save
3. Menu Lock
4. Other Option
IX. Auxiliary menu
1. Replace Electrodes
2. Stabilize Electrodes
3. Clear Arc Count
4. Set Calendar
X. Error messages
1. FIBER DIRTY
2. REPLACE POSITION
3. TOO LONG FIBER
5. LOSS LIMIT OVER
6. FIBER THIN ERROR
7. FIBER THICK ERROR
8. CORE BUBBLE
XI. Solutions to splicing problems
1. High loss Limit
2. Abnormal splice operation
Ⅻ. Other menus
1. Diagnostic test
2. Dust Check
3. Motor Drive
53
53
54
55
58
60
65
65
65
65
66
66
66
67
68
68
69
70
70
71
44
47
50
60 60
62
63
63
70
4. Splice Option 49
5. Sensor value 64
4. FIBER OVER ANGLE 66

3
4. Maintenance information
Ⅼ. Q & A
1. Power supply
3. Tube heater operation
4. Management
5. Other settings
Ⅽ. PC Program set up
1. PC Program set up
Ⅾ. Warranty period and contact address
1. Warranty period and limitation
2. Before you present the splicer for warranty service
3. Information required for repair service
4. Splicer transportation
5. Repair
Warranty
72
73
73
76
76
77
84
84
84
84
85
78
78
2. Splice operation 74
85

4
Keyman S1 has been designed and manufactured for convenient use in indoor or
outdoor working conditions. It is easy and simple to use, but please read through
this manual completely to avoid failures and safety accidents before you use it.
Keyman S1 is designed to easily use, but also contains potential danger. Therefore,
this manual contains all necessary instructions to assure safe splice.
Ilsintech(Inc.) is not responsible for equipment damage and personal or
physical damage caused by improper use or modification.
If an abnormal condition such as the following occurs, immediately turn off
power and disconnect the power source. Next, contact the maintenance service
personnel in Ilsintech(Inc.).
If unusual smoke, noise or odor or unusual overheating occurs,
If foreign substance or liquid gets inside the splicer, or
If the splicer is dropped from a high place or suffers damage
Do not use AC power code other than the allowable power cord indicated.
Doing so may cause a fire, electric shock or injury. Use the power code
provided with S1.
Do not touch the electrodes when S1 is switched on. High voltage and High
Make sure that there is no dust or foreign substance inside the AC plug. Then,
Connect AC power cord to the specified charger and the outlet. Unsafe splice may
cause smoke, fire, equipment damage, serious injury or death.
Ⅰ. Safety guide
Please keep this manual with the product all the time.
Warning
temperature from them may cause serious shock or a burn.

Do not use a voltage other than the allowable power voltage indicated.
AC power supply for the specified charger is AC 100-240V, 50-60Hz.
improper range may cause electric shock, equipment damage, serious injury or
even a death. Abnormally high AC output voltage or frequency from the generator
is a common problem. Measure AC output voltage with a circuit tester before
connecting AC power cord. Regular inspection is needed because improper high
voltage or frequency from the generator may cause serious injury, electric shock,
equipment damage or death.
Do not severely pull, heat or modify the provided AC power cord. The use of
damaged power cord may cause hazardous conditions such as fire or injury.
cable or plug.
To reduce the risk of electric shock, do not touch the AC plug, the AC power code
and the splicer with wet hands.
Do not disassemble AC adapter, battery or the splicer. Any modification to the
splicer may cause a fire, electric shock or injury.
When you use external battery, see the following instructions.
The use of improper external battery may cause smoke, equipment
damage, or in serious cases burning, injury or death.
Do not throw the battery into a fire or a garbage dump.
Do not charge the battery close to flames.
Do not give severe vibration or shock to the battery.
If the battery is not fully charged within 6 hours or green LED lamp
Do not place any object on AC adapter during charging.
Only use the specified battery charger(S-1B) and the specified battery pack(S-1B).
The use of any battery pack other than the specified one may cause smoke or fire,
equipment damage, injury or death.
Warning
Please check the AC power supply before using. AC power supply within the
Connect only to 3-core AC power cord. Do not connect to 2-core power cord,
is not on, immediately stop charging and contact Ilsintech(Inc.)
5

Warning
Only use the specified battery charger(S-11).
Do not use AC power other than the allowable power indicated.
Do not let battery(S-1B) or the terminal of the specified charger be short-
circuited. Excessive current flow may cause damage to the equipment and
persons.
Avoid the use of S1 in a hazardous location in which harmful gas or flammable
gas can generate. In such conditions, the electrical arc of the fusion splicer can
result in bursting or fire.
Do not use compressed gas to clean S1.
If you carry the transport case connected with a belt, first check the belt is
strong enough. The worn belt may fail to sustain the case, resulting in equipment
loss or injury.
Wear safety glasses for protection from glass fibers. Glass fibers may cause serious
damage to eyes or skin tissue.
Do not use the splicer in high temperature conditions. Doing so may cause
equipment loss or injury.
Do not use a splicer in high temperature conditions. Doing so may cause
equipment loss or injury.
6

During or after heating protection sleeves in the tube heater, do not touch both
parts. Injury from high temperature could occur.
Do not place S1 in unstable locations. If the equipment is dropped, injury or
equipment damage could occur.
S1 is a precision instrument. It should be handled with care and precision. When
transporting it, use its specified transport case to protect it from dust, dust,
moisture, shock and impact.
Replace the electrodes the right way.
Only use the specified electrodes.
Place the new electrode in the right position.
Replace the electrodes in pairs.
Not doing so may cause abnormal arc and equipment damage or deterioration in
splice performance.
Only use ethyl alcohol (more than 96 %) to clean the splicer including object
lenses, V-grooves, wind-proof glass, LCD monitor, and the main body.
To prevent modification, discoloration and low performance, do not use any kind
of chemicals.
Do not use lubricants including oil and grease for S1. Doing so may cause
performance deterioration and equipment damage.
Do not store the equipment in high-temperature or high-humidity conditions.
Equipment damage could occur.
Qualified experts should check up technical matters concerning S1. Not doing so
may cause fire or electric shock. Please contact qualified service personnel in
Ilsintech(Inc.) and get A/S service.
Caution
7

8
1. Parts of the splicer
Other accessory items
- Carrying case
- Instruction manual
Ⅱ. Product Structure
S1 main unit S-1B battery pack
AC cord S-11 battery charger

2. Requirements for splicing
Fiber type 0.25mm 0.9mm
Basic sleeves
9
length 40mm length 60mm
Optical fiber
protection
sleeves
Micro sleeves
length 45mm
length 20mm
length 25mm
length 34mm
Optical fiber
stripping
tools
Coating stripper
Optical fiber cleaver [CI-03]
Optical fiber
cleaving tools
Optical fiber holder [standard]
)
cleave length : 16mm (fixed)
cleave length : 5 ~ 20mm(variable
Optical fiber holder [FTTH]
cleave length : 10mm (fixed)
length : 5 ~
(variable)
cleave
20mm
Optical fiber
cleaning tools
Use cotton or gauze pad and alcohol dispenser.
Ethyl alcohol (purity > 96%)
Autres manuels pour Keyman S1
2
Table des matières
Autres manuels Ilsintech Système de soudage
Manuels Système de soudage populaires d'autres marques

TAFA
TAFA 30*8B35 Manuel utilisateur

Lincoln Electric
Lincoln Electric INVERTEC V350-PRO CE Manuel utilisateur

ESAB
ESAB Buddy Arc 145 Manuel utilisateur

CIGWELD
CIGWELD 636804 Guide rapide

Red-D-Arc
Red-D-Arc DC-400 Manuel utilisateur

Hobart Welding Products
Hobart Welding Products Spool Gun DP 3035-10 Manuel utilisateur