IKUSI STC 200 Manuel utilisateur

User manual
STC
200
REF. 4466


4 General safety instructions
4 Types of notices
5 Basic safety instructions
6 Introduction
6 General description
7 General use of the headend
8 Basic installation and configuration
8 Assembly, connection of signals and power supply
9 Description of the user interface
10 IKUNET bus configuration
15 Configuration of general parameters
16 Module configuration
22 Service Management
25 Advanced functions
25 Save/Restore Function
25 Internet Access
26 Network functions
27 Advanced global transport processing
28 Reports
32 CE Certificate
32 STC-201
Contents

4
General safety instructions
JRead all of this user manual carefully before plugging in the unit.
JAlways have these instructions to hand during installation.
JFollow all of the instructions and safety notices regarding unit handling.
Types of notices
The meaning of the safety notices used in this manual are described below.
DANGER OF DEATH OR INJURY
This safety notice indicates a possible danger for the life and health of people.
Not following these instructions may lead to serious consequences to health and
may even cause fatal injuries.
RISK OF DAMAGE TO THE UNIT
This safety notice indicates a possible dangerous situation. Not following these
instructions may lead to the unit being damaged.
NOTE
This type of notice is a note containing applicable advice and useful information
for optimum use of the unit.
HANDLING THE INSIDE OF THE UNIT IS FORBIDDEN
This notice forbids any work that may affect the working order of the unit or its
warranty.
DO NOT DISPOSE OF AS URBAN WASTE
This type of notice indicates that the unit must not be disposed of as unselected
urban waste.
DANGER
ATTENTION

General safety instructions/Basic safety instructions
5
General safety instructions/Basic safety instructions
Basic safety instructions
DANGER OF DEATH OR INJURY
JDo not install the unit during an electrical storm. This could lead to electro-
static discharge from lightning.
JDo not open the unit. There is a risk of electrostatic discharge.
RISK OF DAMAGE TO THE UNIT
JThe unit must be appropriately ventilated. Install the unit in a dust-free
location. Do not place the unit in a location where the ventilation slots are
covered or blocked. Install the unit in a location with at least 20 cm around it
free of other objects.
JDo not expose the unit to rain or moisture. Install the equipment in a dry lo-
cation with no inltration or condensation of water. Should a liquid enter the
unit, disconnect it immediately from the mains.
JKeep the unit away from ammable objects, candles and anything that may
cause a re.
JConnect the unit to an easily accessible power socket. In the event of an
emergency, it will then be possible to quickly unplug the unit.
JDo not expose the unit to sources of heat (sun, heating, etc.).
DANGER
ATTENTION
EN

Introduction/General description
6
Introduction
JTo ensure the correct use and installation of the headend, it is necessary to read the
user and troubleshooting procedure manuals corresponding to the complete solution
and to each of the individual modules.
JIKUSI reserves the right to modify the contents of this manual without prior warning.
General description
The headend described in this manual is made up of the following modules:
JSTC-200 (Ref. 4466): DVB-S/S2 to DVB-T transmodulator (QPSK/8PSK to COFDM).
JCFP-507 (Ref. 4439): power supply +12 V/+24 V.
5
6
7
8
1
2
3
4
9
10
11
12
13
14
15
16
STC-200
KEY
A STC-200 module
B CFP-700 module
C CFP-507 module
1 Input 1 DVB-S/S2 channel
2 Input 2 DVB-S/S2 channel or loop output
3 LNB remote power supply
4 Slot for CAM
5 DB-9 port
6 DC power supply
7 RJ-45 ports for IKUNET bus
8 Coupling loop DVB-T output
9 Output +12 V (5 A)
10 Output +24 V (60 mA)
11 Output +18 V/22 kHz (300mA)
12 Output +13 V/22 kHz (300mA)
13 Output +18 V/0 kHz (300mA)
14 Output +13 V/0 kHz (300mA)
15 Output +12 V (7 A)
16 Output +24 V (60 mA)

7
Introduction/General use of the headend
7
JCFP-700 (Ref. 4401): power supply +12 V/+24 V for selection of polarisation.
JBAS-900 (Ref. 4411): base-support with capacity for 9 modules (dimensions:
563x257x24 mm).
JMS-0504 (Ref. 1023): stand-alone multiswitch (4 SAT inputs and 4 outputs).
NOTE
Please read the detailed information in the manuals for the modules included in
their respective packaging.
General use of the headend
This headend is designed for the emission of DVB-T (COFDM) signals from the input of free
or encrypted DVB-S/S2 signals (QPSK/8PSK to COFDM).
NOTE
The DVB-T (COFDM) output signal requires a trunk amplier for the correct distri-
bution in installations for a large number of sockets.
ENEN

Basic installation and configuration/Assembly, connection of signals and power supply
8
Basic installation and configuration
NOTE
A PC with an Ethernet network card and a CAT-5E Ethernet crossover cable are
required for communication with the headend.
NOTE
To display the graphics provided in the headend conguration program correctly,
we recommend installing the Mozilla Firefox web browser (www.mozilla.com) in
the control PC.
Assembly, connection of signals and power supply
1) Attach the modules to the base one by one following the instructions given in the
manuals for each module.
NOTE
IKUSI recommends the modules are assembled in the order shown in the above
gure:
JRight: CFP-700/CFP-507 power supplies.
JLeft: STC-200 transmodulators
JLast STC-200 on the right: Master STC-200 with the DVB-T output signal.
13
2
654
KEY
1 DVB-S/S2 signal input
2 DVB-T signal output
3 Bridging line in loop mode
4 Power supply bridges
5 IKUNET
6 CAM + SmartCard + protection with safety
screws

9
Basic installation and configuration/Description of the user interface
2) Connect the input and output signal connections in accordance with the instructions
for the module manuals and the diagram shown in the previous gure.
3) Distribute the headend power supply as symmetrically as possible (see example in
above gure).
Description of the user interface
The interface permits the user to communicate easily and comfortably with the headend.
The layout of the menus and submenus of the interface is shown in the following diagram:
The upper part of the interface displays messages about the communication status with the
headend. Each message is colour-coded:
FGreen: noties that the instruction has been carried out.
FRed: indicates that the instruction could not be performed and gives the reason.
KEY
1 Exit button
2 Information button
3 Print button
4 Main menu
5 Submenus
6 Tabs
7 Status message
8 Work area
EN

10
Basic installation and configuration/IKUNET bus configuration
IKUNET bus configuration
The IKUNET bus is an Ethernet communication bus between the headend modules. The
IKUNET bus is installed using Ethernet pigtails supplied with the modules. If n is the
number of station modules, n-1 Ethernet pigtails are required.
Definition of the master module
NOTE
JRemember the PC conguration prior to the connection with the IKUNET
bus.
JThe denition of the master module must be made with an STC-200 module.
NOTE
In mixed STC and MTC congurations, an STC module may never be an MTC
module master. In these cases, the master module must be an MTC module and
the STC modules are reserved for conguration as slave modules.
1) Start the conguration of the IKUNET bus for
the headend with the modules disconnected
from each other.
2) Connect the selected module ( A ) to the PC ( B
) via its Ethernet connection and using an RJ-45
cable ( C ).
3) In the PC (Windows XP) go to
.
4) Select the
checkbox. Enter the following IP
conguration parameters:
F: 10.254.254.2
F: 255.255.255.0
F: 10.254.254.1
5) Click on the button.
6) Enter the IP address http://10.254.254.254 in the web browser. This takes you to the
home page of the connected module.
7) In the home page of the selected module, “Admin” appears by default in the
eld. Enter the word “admin” in the eld and click on .
8) The main management window for the STC-200
module as slave module is displayed.
STC-200 STC-200
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels IKUSI Électricité industrielle
Manuels Électricité industrielle populaires d'autres marques

Murata
Murata GJM0335C1E4R4BB01 Series Manuel utilisateur

Stahl
Stahl 8575/12 Manuel utilisateur

SI
SI Pegasus Manuel utilisateur

Murata
Murata GRM1555C1H2R7CA01 Seies Manuel utilisateur

Murata
Murata GRM0225C1E6R4BA03 Series Manuel utilisateur

Cooper Power Systems
Cooper Power Systems VXE15 Manuel utilisateur

S&C
S&C Vista SD Manuel utilisateur

Murata
Murata GRM0335C2A7R3CA01 Series Manuel utilisateur

Siemens
Siemens 3VA9988-0BM10 Manuel utilisateur

Siemens
Siemens SITRANS LVS100 Manuel utilisateur

Murata
Murata GRM32ER60G227ME05 Series Manuel utilisateur

Siemens
Siemens SENTRON SUPERSWITCH 3KL82 Series Manuel utilisateur