Chapter One Brief Introduction and Features
Introduction of TC-2000 System = 2L8P
Fundamental Technical Information
The internal structure
Operating Principle
Features & Specifications
System Features of TC-2000 Series
Specifications
Chapter Two Installation & Connection
Before installation
Safety instllation instructions
Installation precautions
Structural connection
Name of parts
Connecting procedures
Chapter Three System Programming
Remarks
Unlocking Programming Password
CO line ringing assignment
Setting the operating mode
OGM recording
Music on-holding
Set CO Line
Assign Flash time for Call transfer
Assign dial-out mode for extension
Assign CO line to exclusive extension
Extension class assignment
Setting restriction class
Call duration control
Flexible coding
Return to system default settings
The default setting for TC-2000 Series
Chapter Four Operating Instruction
Outward dialing directly
Outward dialing by dialing "0" first
Outward dialing by patting hook
Outward dialing by a exclusive line
Intercom calling
Answering call
Call transfer
Boss/Secretary function
Conference
Call pick up
Call Forwarding
Automatic reporting of extension number
Priority access and monitoring
Table of Contents
..............................................
.............................................
....................................................
......................................................
...................................................
.............................................
.........................................................
......................................................
................................................
....................................................
.....................................................
.........................................................
....................................................
3
3
3
3
4
4
4
5
5
5
6
6
6
19
19
20
20
21
22
23
24
25
26
27
28
28
7
7
8
9
9
10
11
11
12
13
14
15
16
17
18
18

Doorbell & Door lock
Connection instruction
Ringing extension assignment
Answering the call
Doorphone call pickup
To open the lock
Assign Monitor & Recorder
Assign certain C.O line be monitored
Appendix
Doorbell
Door-opener
Telephone Recorder
Chapter Five Maintenance & Troubleshooting
Outgoing calls cann`t be made
Outside calls cann`t dial in
Intercom cann`t be made
Chapter Six Warranty
Warranty
Chapter Seven Appendix
Index of system programming
Table of Contents
....................................................
...................................................
................................................
.....................................................
....................................................
.......................................................
.................................................
............................................
................................................
.................................................
...................................................
............................................................
..........................................................
......................................................
................................................
............................................................
29
29
29
30
30
30
31
31
33
34
35
32
32
32
36
37

Introduction to TC-2000 system
TC-2000 Seires System is "Private Branch Exchange"(abbreviated as PBX), which is a Telephone System that switches
calls between users on internal telephone lines while allowing other users to share a certain number of external telephone lines
Fundamental Technical Information:
We integrate in this model special-purpose telecommunication ICs from American & Japanese companies, for lower
energy consumption, small size, compact appearance, disturbance resistance, high reliability, simple installation and
programming.
The internal structure
Master control system
1.CPU is composed microprocessor, SDRAM and series-parallel conversion circuit.
2.DID/DTMF is composed circuits of auto-attendant, music generating, signal tone generating and audio decoding
circuit.
3.EXT.is composed of ringing testing circuit, contra-polar testing circuit and system multi-function testing circuit.
4.Voice volume amplifying system, which is made of patented amplifying module that enormously, improves the
communication quality.
Extension system
5.Extension pick-up & hang-up testing circuit
6.Special thunder-strike-discharging circuit & buffer circuit
7.Signal exchanging matrix circuit
Power control system
8.DC48v
9.AC65v ringing current generating circuit
Operating Principle
The structure and its operating principle are shown in the following graph.
CO Line, thunder-strike resistance, constant current load, signal exchange matrix, signal tone, ringing testing,
DTMF decoding, memory, CPU, pick-up and hang-up testing, extension, constant current source, ringing activator.
Chapter 1 Brief Introdution & Features
CPU
External line thunder-strike resistance
thunder-strike resistance
constant current load signal exchange matrix signal tone
ringing testing DTMF decoding
memory pick-up and hang-up testing extension
constant current source
ringing activator
Introduction to PBX system

Chapter 1 Brief Introdution & Features Features and Specifications
Features and Specifications
The TC-2000 Series are designed to provide a family and small office with low cost professional telecom service.The
maximum capacity is 1 to 6 CO lines and 8 to 32 Extensions.
The Auto-Attendant Service (DISA: Direct Inward System Access) with OGM (Outgoing Message service) allows the
system to make the Maximum use of the CO line.
System Features of TC-2000 Series
There are number of supplementary features to indicate quality of TC-2000 Series System
OGM Recording with DISA(Auto-attendant)
Call Transfer & Call pickup
Music on holding
Ringing Assignment
Flexible Coding
Seven Level Call Restriction
Call duration control
Automatic distinguishes CO Lines
Power Failure Transfer
Three way conference
Intercom dialing
Multiple communication lines
Caller ID
Call Forwarding
Doorbell and door lock
Monitor and recorder
Specifications
1.Capacity: CO Lines: 1 to 6
Extensions: 8 to 32
2.Exterior sockets: Conjunction for extensions,
3.Communication lines: 7
4.Transmission attributes: Extension to extension 1.5dB;
Extension to trunk line 2.0dB;
5.Ringing current: 65v/50Hz;
6.Feeding current: 48v-60v/25mA;
7.Relative unbalance against ground:300Hz-600Hz 40dB;
600Hz-3400Hz 46dB;
8.Dialing mode: DTMF
9.Signal tone:
CO Line: tone from local telephone company;
Internal dialing tone: 450Hz, continuous wave;
Extension echo signal: 450Hz, 1 second on and 4 seconds off;
Extension busy signal: 450Hz, 0.3 second on, 0.3 second off;
Extension confirmation signal: 450Hz, 1 second on;
Extension error signal: 450Hz, 0.3 second on, 0.3 second off ;
10. Power supply: AC220V/110V 10% Power consumption: 15VA
11. Operational environment: Temperature: 32F-104F(0 C-40 C);
Relative humidity 90%

Chapter 2 Installation & Connection
Before Installation
For easy and quick installation and connection, it is strongly recommended that the user read and follow the following
instruction carefully so as not to damage the system accidentally by incorrect operation.
Safety Installation Instructions
When installing telephone wires, basic safety precautions should always be followed to reduce the risk of fire, electric
shock and injury to persons. Including the following:
1). Never install telephone wires during a lighting storm.
2). Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.
3). Never touch UN-insulated telephone wires or terminals unless the telephone line has been disconnected at the
network interface.
4). Use caution when installing or modifying telephone lines.
Installation precautions
This set is exclusively made for wall mounting or set on desk. Avoid installing in the following places (Doing so may
result in malfunction, noise, or discoloration).
1). In direct sunlight, hot, cold, or humid places. (Temperature range: 0 C-40 C / 32F-104F)
2). Places in which shocks or vibrations are frequent or strong.
3). Dusty places, or places where water or oil may come into contact with the unit.
4). Near high-frequency generating devices such as sewing machines or electric welders.
5). On or near computers, telexes, or other office equipment, as well as microwave ovens or air conditioners ( It is
preferable not to install in the same room with the above equipment).
6). Install at least 6 feet from radios and televisions.
7). Do not obstruct area around the main unit (for reasons of maintenance and inspection be especially careful to allow
space for cooling above and at the sides of the main unit).
Power Failure
In the event of power fialure, CO.1 to CO.4 will be connected to EXT.801--804 automatically. But CO.5 & CO.6 can`t be
used for 6 CO line unit.
Before Installation
Call ID
FSK/DTMF compatible Caller ID function is successfully equipped on TC-2000 system. The steps are as below:
1). Go to your telecom office applying the Caller ID service.
2).
3). An incoming call number will be displayed on the phone with Caller ID function. But the number will disapper when
you transfer the call to another extension.
4). For some area the Caller ID function is invalid because of the Telecom Singal of the area.
Extension 801-808 can realize the caller ID function.

Structural connection:
Structural connection
2
3
5
4
6
8
10
7
9
11
Front View
Front View
Model TC-108/208/308/408 Back View
Model TC-312/316/416 Back View
Model TC-424/432/624/632 Back View
1
2
3
4
5
6
7
8
9
11
10
Name of parts:
Led for power supply and working
Power supply switch
CO line and door bell port
Extension jacks for 801 to 808
Power supply jack
The first 4 sockets are CO line port 1 to 4
Extension jacks for 801 to 816
CO line port 4, 5 & 6
Extension jacks for 817 to 832
Extension jacks for 801 to 816
CO line port 1, 2 & 3
Connecting Procedures:
1. Connecting CO lines & extensions to the unit:
1). Please connect the monomer-crystal with EXT.
line and CO line separately;
2). Make sure to avoid short circuit;
3). Connecting extensions according to the in-
dicated extension positions and CO lines
to the correspanding line ports on the unit.
2. Zero-load power-on inspection:
1). The operation voltage of this product is
AC220V/110V 10%. Check out the voltage of
local power supply. A UPS backup is highly
recommended.
2). Plug in the power supply line and turn on
the switch; indicating normal power supply
and working state of the machine.
3). Pick up the handset of extension 801.A sharper
internal dial tone indicates that the system
is working normally.You can start to setup
operation now.
state of CO lines & extensions
1
1
2000E
2000A

Chapter 3 System Programming
3 0 0 Remarks
3 0 0 1 All the function setting must be carried out on extension 801 and un-lock first;
3 0 0 2 All the extensions must be of double tone;
3 0 0 3 Press * to start setting and press # to end the setting. You don`t have to hang up if something wrong occurs
during the setting. You may restart the setting by simply pressing * again;
3 0 0 4 If extension 801 is in direct dialing out mode, you need to press * to enter the internal system, and press it
again to start programming;
3 0 0 5 When the setting is finished, a long beep indicates that the setting is done correctly and saved in the system.
If instead an array of short chirps is heard,that would indicate an error occurred in the setting. You need to
check it out and reset the system;
3 0 0 6 All the setting involved multiple users can be carried out in a batch process mode. It will surely increase the
speed and accuracy of the setting.
3 0 1 1 Un-locking Programming Password
Format: * 01 abcd #
Explanation: abcd is the password.
The default Password is 1234
3 0 1 2 Changing the Password
Format: * 02 abcd #
Explanation: abcd is the new password.
*b
2d
0c
a#
Pick up 801 Input * 02 abcd # You will hear du hang up
The system must be unlocked before programming.(see 3.0.1.1)
*b
1d
0c
a#
Pick up 801 Input * 01 abcd # You will hear du programming
Unlocking Programming Password

Chapter 3 System Programming Co Line Ringing Assignment
Format: * 1 m abcd #
Explanation: [1] Shift to incoming calls program mode;
[m]: CO Line port No.;
[a b c d]: The last digits of extensions(801--808);
Description: Assigns the extensions, which will ring when incoming call from CO lines is received.
Example: If you wish extension 802 to ring from an incoming call for CO line 1, and extensions 803 and
806 to ring for CO line 2 incoming calls, then you may perform the following operation:
1>. The default ringing extensions are extensions 801 to 804;
2>. Ringing extensions must be among extensions 801 to 808;
3>. At most 8 extensions can be set to ring for one CO line, if the ringing extensions less than 8 then end
with #;
4>. The system must be unlocked before programming.(see 3.0.1.1)
3 1 CO Line Ringing Assignment
* 1
1 3
# #*
1 2
2 6
Pick up 801 Input * 1 1 2 # You will hear du Input * 1 2 3 6 # You will hear du Hang up

Format: * 2 1 #
Description: In this mode, the ringing extensions will ring when an incoming call is received.
Format: * 2 0 #
Description: Caller will hear the OGM recorded message, while all extensions are in MUTE mode.
1>. The recording time is a maximum of 12 seconds, du is heard to start recording and another du to end
recording;
2>. No restricting for the recording times and the new message overwrite the old one;
3>. Please use high quality telephone to ensure high quality of recording;
4>. If the caller dials a number before the system finishes playing the message, the system will terminate
playing the message, waiting for the caller to complete dialing;
5>. The caller will be connected to extension 802 if he/she dial 0 first for inquiry;
6>. If a busy extension is dialed,the system will search for a vacant one increasingly beginning from extension
802.
3£®2 Setting the operating mode
Setting the operating mode
3£®2£®1 Operator mode
3£®2£®2 Set Auto-Attendant (OGM)
*
*
1
0
2
2
#
#
Chapter 3 System Programming
Pick up 801 Input * 2 1 # You will hear du Hang up
Pick up 801 Input * 2 0 # You will hear du Hang up
9
and unlock
Format: * 2 2 #
Description: Used to record an outgoing message for Direct Inward System Access(DISA).
3£®2£®3 OGM Recording
*22 #
Pick up 801 Input * 2 2 # Du,begin to record Recording Du, ending Hang up
and unlock
and unlock

Format: * 2 3 #
Description: Confirms the recorded message in the OGM recording program.
Format: * 2 4 #
Description: Allows to hear music on holding melody or to test the quality of telephone unit.
3£®2£®4 OGM Play
3£®2£®5 Music on-holding
*
*
3
4
2
2
#
#
Chapter 3 System Programming Setting the operating mode
Pick up 801 Input * 2 3 # Du,starting Playing Du,ending Hang up
Pick up 801 Input * 2 4 # Du,starting Playing music Du,ending Hang up
10
and unlock
and unlock
3£®2£®6 The DISA optional:
A1. Format: * 25 1 #
At auto-attendant mode, if the C.O line doesn't dial the extension number in 8 seconds after hearing the OGM, then
the C.O line will be cut off.
A2. Format: * 25 2 #
At auto-attendant mode, if the C.O line doesn't dial the extension number in 8 seconds after hearing the OGM, the
C.O line will be transferred to extension 802.
B1. Format: * 25 3 #
At auto-attendant mode, if the C.O line dials the extension number but the called extension doesn't
answer the call then the C.O line will be cut off.
B2. Format: * 25 4 #
At auto-attendant mode, if the C.O line dials the extension number but the called extension doesn't
answer the call then the C.O line will be transferred to extension 802.
Four kinds of combination for DISA: A1B1, A1B2, A2B1, A2B2.
The default mode is "A1" and "B1".
Table des matières
Manuels PBX populaires d'autres marques

Allo.com
Allo.com Nano 2 Manuel utilisateur

ZYCOD
ZYCOD ZX50 Manuel utilisateur

Panasonic
Panasonic KX-TDA100BX Manuel utilisateur

LV switch
LV switch IPPBX800 Manuel d'instructions

Edge-Core
Edge-Core VST3305 Manuel utilisateur

Panasonic
Panasonic KX-T7625 - Digital Proprietary Speakerphone 24... Manuel utilisateur

Rauland-Borg
Rauland-Borg Telecenter IV Manuel utilisateur

Grandstream Networks
Grandstream Networks UCM6208 Manuel utilisateur

ATCOM
ATCOM IPPBX IP02 Manuel utilisateur

Panasonic
Panasonic KX-TVS50 - 2 Port Voicemail System Manuel utilisateur

bintec elmeg
bintec elmeg elmeg hybird 600 Manuel utilisateur

Panasonic
Panasonic KX-NS300 Manuel utilisateur