www.IFBlue.com 5
Clear a Preset Selection
1. Press PRESET to display the preset page.
2. Press either UP or DOWN arrow buttons (tuning as you scroll) or PRESET
+ UP and PRESET + DOWN (selecting the preset without tuning) to
select the preset number you wish to clear.
NOTE: If there is an E next to the preset number, the slot is already
clear (empty).
3. Press and hold PRESET + DOWN to clear the slot. The E will appear and
the preset number will blink, indicating the slot is now empty.
Setup Pages
Circular Navigation of Setup Pages
To access the setup pages, hold down the PRESET button while powering on.
From there, use the FREQ and PRESET buttons to navigate circularly among
the setup pages. To leave the setup pages, power off and on again.
Battery Type Selection
To access the battery selection option, hold down the PRESET button while
powering on. The display will show bat L or bat A. Use either the UP or
DOWN arrows to toggle through these two options. If installing Lithium bat-
teries, select the bat L setting and then turn off the unit to save this option. If
installing either Alkaline or NiMH batteries select the bat A setting and then
turn off the unit to save this option.
Below the Freq button ( button just left of the up-arrow) is a switch with a red
cap. This switch should be in the PRIMARY position for Lithium and Alkaline
batteries and should be in the NiMH position for rechargeable NiMH batteries.
This red capped switch, when in the NiMH position, engages the charging
contacts on the bottom of the unit, while this switch is in the PRIMARY posi-
tion the charging contacts are disengaged.
To recharge NiMH batteries, use the IFBlue CHSIFBR1C charger (see page
7), which can charge four IFBR1C units simultaneously.
Backlight Settings
Press the PRESET button while powering on the receiver. Press the PRESET
button again to display the Backlight page. Use the UP and DOWN arrow but-
tons to scroll through the options:
bL on: Backlight always on; default setting
bL 30: Backlight times out after 30 seconds
bL 5: Backlight times out after 5 seconds
Power off the unit to exit and save the settings.
Warning: Do not mix battery types. Use either two Lithium 1.5V batteries, or
two Alkaline batteries, or two NiMH batteries.
Warning: Do not place the red cap switch in the NiMH position when using the
other two type batteries, either Lithium or Alkaline. Any attempt to recharge
Lithium or Alkaline batteries can lead to damaging both the unit and the
batteries.